Effects of CoCr metal wear debris generated from metal-on-metal hip implants and Co ions on human monocyte-like U937 cells

被引:43
作者
Posada, Olga M. [1 ]
Tate, Rothwelle J. [2 ]
Grant, M. Helen [1 ]
机构
[1] Univ Strathclyde, Dept Biomed Engn, Wolfson Ctr, Glasgow G4 0NW, Lanark, Scotland
[2] Univ Strathclyde, Strathclyde Inst Pharm & Biomed Sci, Glasgow G4 0RE, Lanark, Scotland
关键词
Metal wear debris; Hip replacements; Nanoparticles; Metal ions; Cobalt-chrome alloy; Monocytes; COBALT-CHROMIUM ALLOY; PARTICULATE COBALT; IN-VITRO; INFLAMMATORY RESPONSE; HUMAN OSTEOBLASTS; TNF-ALPHA; MACROPHAGES; PARTICLES; ARTHROPLASTY; EXPRESSION;
D O I
10.1016/j.tiv.2014.11.006
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Hip resurfacing with cobalt-chromium (CoCr) alloy was developed as a surgical alternative to total hip replacement. However, the biological effects of nanoparticles generated by wear at the metal-on-metal articulating surfaces has limited the success of such implants. The aim of this study was to investigate the effects of the combined exposure to CoCr nanoparticles and cobalt ions released from a resurfacing implant on monocytes (U937 cells) and whether these resulted in morphology changes, proliferation alterations, toxicity and cytokine release. The interaction between prior exposure to Co ions and the cellular response to nanoparticulate debris was determined to simulate the situation in patients with metal-on-metal implants receiving a second implant. Effects on U937 cells were mainly seen after 120 h of treatment. Prior exposure to Co ions increased the toxic effects induced by the debris, and by Co ions themselves, suggesting the potential for interaction in vivo. Increased TNF-alpha secretion by resting cells exposed to nanoparticles could contribute to osteolysis processes in vivo, while increased IFN-gamma production by activated cells could represent cellular protection against tissue damage. Data suggest that interactions between Co ions and CoCr nanoparticles would occur in vivo, and could threaten the survival of a CoCr metal implant. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:271 / 280
页数:10
相关论文
共 65 条
  • [1] Distribution of metal released from cobalt-chromium alloy orthopaedic wear particles implanted into air pouches in mice
    Afolaranmi, Grace A.
    Akbar, Moeed
    Brewer, James
    Grant, M. Helen
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2012, 100A (06) : 1529 - 1538
  • [2] Release of soluble metal ions from copper based dental alloys measured by ICPMS
    Afolaranmi, Grace A.
    Al-Mufti, Hassan
    Grant, M. Helen
    [J]. TOXICOLOGY, 2011, 290 (2-3) : 119 - 119
  • [3] Acute inflammatory response to cobalt chromium orthopaedic wear debris in a rodent air-pouch model
    Akbar, Moeed
    Fraser, Alasdair R.
    Graham, Gerard J.
    Brewer, James M.
    Grant, M. Helen
    [J]. JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2012, 9 (74) : 2109 - 2119
  • [4] Effect of chromium and cobalt ions on primary human lymphocytes in vitro
    Akbar, Moeed
    Brewer, James M.
    Grant, M. Helen
    [J]. JOURNAL OF IMMUNOTOXICOLOGY, 2011, 8 (02) : 140 - 149
  • [5] The effects of particulate cobalt, chromium and cobalt-chromium alloy on human osteoblast-like cells in vitro
    Allen, MJ
    Myer, BJ
    Millett, PJ
    Rushton, N
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (03): : 475 - 482
  • [6] Effects of cobalt and chromium ions at clinically equivalent concentrations after metal-on-metal hip replacement on human osteoblasts and osteoclasts: Implications for skeletal health
    Andrews, Rebecca E.
    Shah, Karan M.
    Wilkinson, J. Mark
    Gartland, Alison
    [J]. BONE, 2011, 49 (04) : 717 - 723
  • [7] [Anonymous], 2010, MDA2010069
  • [8] Metal ion levels in the blood of patients after hip resurfacing: A comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses
    Antoniou, John
    Zukor, David J.
    Mwale, Fackson
    Minarik, William
    Petit, Alain
    Huk, Olga L.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A : 142 - 148
  • [9] BANK HL, 1988, IN VITRO CELL DEV B, V24, P266
  • [10] Metal ion levels in patients with a lumbar metal-on-metal total disc replacement SHOULD WE BE CONCERNED?
    Bisseling, P.
    Zeilstra, D. J.
    Hol, A. M.
    van Susante, J. L. C.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (07): : 949 - 954