Experimental evaluation of heat transfer performance of falling film evaporator for wastewater source heat pump with backwash system

被引:5
|
作者
Zhang, Qunli [1 ,2 ]
Zhang, Xinchao [1 ,2 ]
Yin, Chaohui [3 ]
Liu, Fang [1 ,2 ]
Wang, Gang [1 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Beijing Adv Innovat Ctr Future Urban Design, Beijing 100044, Peoples R China
[2] Beijing Univ Civil Engn & Architecture, Beijing Key Lab Heating Gas Supply Ventilating &, Beijing 100044, Peoples R China
[3] China Mobile Grp Design Inst Co Ltd, Beijing 100044, Peoples R China
关键词
Direct wastewater source heat pump; Falling film evaporator; Flooded evaporator; Heat transfer coefficient; Scale removal; HORIZONTAL TUBES; SEWAGE; COEFFICIENTS; EXCHANGER; BUNDLE; ARRAYS; R-134A;
D O I
10.1016/j.ijrefrig.2020.01.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
Urban wastewater contains large amounts of waste heat and the wastewater source heat pump (WWSHP) offers an effective way to use this heat. Increasing the overall heat transfer coefficient (OHTC) of the evaporator is an effective mean to improve the performance of the heat pump. In this work, falling film evaporator(FFE) is used in direct WWSHP. A WWSHP unit that can switch evaporators is first established. The effects of practical application of this WWSHP are then tested and compared with simulation results. Under the test conditions, the average OHTC of the wastewater FFE (WFFE) reaches 1960.90 W m(-2) K-1, while the average OHTC of a wastewater flooded evaporator (WFE) 1224.28 W m(-2) K-1. The average OHTC of the WFFE was thus 60.17% higher than that of the WFE and COP of the WFFE is 9.52% higher than that of the WFE. The experiment also explores the wastewater backwash, which can ensure stable operation of the unit. When using the backwash mode, the backwash time interval was set to be as short as possible to ensure that the average OHTC would not decrease. A mathematical model of the OHTC of the WFFE is presented. Using the wastewater condition as a basis, the mathematical model is used to synthetically calculate the shell side HTC of the WFFE, the convection HTC of the wastewater and the heat resistance of the tube walls and the fouling. From the experimental results, an influence factor for the wastewater down-and-up mode is proposed to revise the formula. (C) 2020 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:80 / 93
页数:14
相关论文
共 50 条
  • [31] Experimental Investigation of Heat Transfer Coefficient in Vertical Tube Rising Film Evaporator
    Ul Hasan, Syed Naveed
    Ali, Sultan
    MEHRAN UNIVERSITY RESEARCH JOURNAL OF ENGINEERING AND TECHNOLOGY, 2011, 30 (04) : 539 - 548
  • [32] Performance Evaluation of a Hyperloop Ground Source Heat Pump System in a Residential Building
    Miao, Rui
    Yu, Yao
    Hu, Xiaoou
    Gordon, Richard A.
    ASHRAE TRANSACTIONS 2023, VOL 129, PT 1, 2023, 129 : 34 - 41
  • [33] Heat transfer enhanced surfaces for horizontal tube falling film evaporator characterized using laser interferometry
    Ganesan, A. R.
    Mani, A.
    Maliackal, Akhil Krishnan
    APPLIED THERMAL ENGINEERING, 2022, 210
  • [34] Heat transfer in condensation and boiling in a tubular film evaporator
    N. A. Voinov
    O. P. Zhukova
    A. N. Nikolaev
    Theoretical Foundations of Chemical Engineering, 2012, 46 : 359 - 367
  • [35] Experimental investigation of the cooling performance of a ground source heat pump system in Denizli, Turkey
    Karabacak, Rasim
    Acar, Sengul Guven
    Kumsar, Halil
    Gokgoz, Ali
    Kaya, Mustafa
    Tulek, Yahya
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (02): : 454 - 465
  • [36] An Experimental Study on Heat Transfer of a Falling Liquid Film in Air Channel Flow
    Oh, Dongeun
    Kang, Byung Ha
    Kim, Sukhyun
    Lee, Dae-Young
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2008, 32 (05) : 335 - 341
  • [37] Experimental study of falling film evaporation heat transfer coefficient on horizontal tube
    Mu, Xingsen
    Shen, Shengqiang
    Yang, Yong
    Liu, Xiaohua
    DESALINATION AND WATER TREATMENT, 2012, 50 (1-3) : 310 - 316
  • [38] Improvement in heat transfer and flow pattern of sprayed falling on horizontal tubes with rib structure for a sewage source heat pump
    Meng, Shuangshuang
    He, Zhihao
    He, Tianbiao
    Mao, Ning
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2025, 208
  • [39] Experimental study of heat transfer of buried finned pipe for ground source heat pump applications
    Koyun, Ahmet
    Demir, Hakan
    Torun, Zakir
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2009, 36 (07) : 739 - 743
  • [40] Review on liquid film flow and heat transfer characteristics outside horizontal tube falling film evaporator: Cfd numerical simulation
    Wang, Qifan
    Li, Minxia
    Xu, Wenjie
    Yao, Liang
    Liu, Xuetao
    Su, Dandan
    Wang, Pai
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 163