Experimental evaluation of heat transfer performance of falling film evaporator for wastewater source heat pump with backwash system

被引:5
|
作者
Zhang, Qunli [1 ,2 ]
Zhang, Xinchao [1 ,2 ]
Yin, Chaohui [3 ]
Liu, Fang [1 ,2 ]
Wang, Gang [1 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Beijing Adv Innovat Ctr Future Urban Design, Beijing 100044, Peoples R China
[2] Beijing Univ Civil Engn & Architecture, Beijing Key Lab Heating Gas Supply Ventilating &, Beijing 100044, Peoples R China
[3] China Mobile Grp Design Inst Co Ltd, Beijing 100044, Peoples R China
关键词
Direct wastewater source heat pump; Falling film evaporator; Flooded evaporator; Heat transfer coefficient; Scale removal; HORIZONTAL TUBES; SEWAGE; COEFFICIENTS; EXCHANGER; BUNDLE; ARRAYS; R-134A;
D O I
10.1016/j.ijrefrig.2020.01.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
Urban wastewater contains large amounts of waste heat and the wastewater source heat pump (WWSHP) offers an effective way to use this heat. Increasing the overall heat transfer coefficient (OHTC) of the evaporator is an effective mean to improve the performance of the heat pump. In this work, falling film evaporator(FFE) is used in direct WWSHP. A WWSHP unit that can switch evaporators is first established. The effects of practical application of this WWSHP are then tested and compared with simulation results. Under the test conditions, the average OHTC of the wastewater FFE (WFFE) reaches 1960.90 W m(-2) K-1, while the average OHTC of a wastewater flooded evaporator (WFE) 1224.28 W m(-2) K-1. The average OHTC of the WFFE was thus 60.17% higher than that of the WFE and COP of the WFFE is 9.52% higher than that of the WFE. The experiment also explores the wastewater backwash, which can ensure stable operation of the unit. When using the backwash mode, the backwash time interval was set to be as short as possible to ensure that the average OHTC would not decrease. A mathematical model of the OHTC of the WFFE is presented. Using the wastewater condition as a basis, the mathematical model is used to synthetically calculate the shell side HTC of the WFFE, the convection HTC of the wastewater and the heat resistance of the tube walls and the fouling. From the experimental results, an influence factor for the wastewater down-and-up mode is proposed to revise the formula. (C) 2020 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:80 / 93
页数:14
相关论文
共 50 条
  • [21] Heat transfer correlation for absorption chillers through investigation of falling film evaporator data
    Lee, Won-Jong
    Bae, Kyung Jin
    Kwon, Oh. Kyung
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 159
  • [22] Experimental and Numerical Testing of Heat Pump Evaporator
    Santa, Robert
    Bosnjakovic, Mladen
    Cikic, Ante
    APPLIED SCIENCES-BASEL, 2022, 12 (23):
  • [23] Experimental study of falling film evaporation heat transfer outside horizontal tubes
    Yang, Luopeng
    Shen, Shengqiang
    DESALINATION, 2008, 220 (1-3) : 654 - 660
  • [24] Three-dimensional heat transfer coefficient distributions in a large horizontal-tube falling film evaporator
    Gong, Luyuan
    Shen, Shengqiang
    Liu, Hua
    Mu, Xingsen
    Chen, Xue
    DESALINATION, 2015, 357 : 104 - 116
  • [25] The heat transfer performance of horizontal tube bundles in large falling film evaporators
    Yang, Li
    Wang, Wen
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (01): : 303 - 316
  • [26] HEAT TRANSFER COEFFICIENT IN FALLING FILM EVAPORATORS WITH DIFFERENT TUBE ARRANGEMENTS
    Shen, Shengqiang
    Liang, Gangtao
    Guo, Yali
    Mu, Xingsen
    Liu, Rui
    Yang, Yong
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, 2012, VOL 2, 2012, : 873 - 879
  • [27] Experimental data and modelling of a dual source reversible heat pump equipped with a minichannels evaporator
    Zanetti, Emanuele
    Azzolin, Marco
    Bortolin, Stefano
    Busato, Giulio
    Del Col, Davide
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2022, 35
  • [28] Performance and heat transfer characteristics of hydrocarbon refrigerants in a heat pump system
    Chang, YS
    Kim, MS
    Ro, ST
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2000, 23 (03): : 232 - 242
  • [29] Experimental study on overall heat transfer coefficient of seawater on three tube arrangements for horizontal-tube falling film evaporator
    Mu, Xingsen
    Shen, Shengqiang
    Yang, Yong
    Liang, Gangtao
    Chen, Xue
    Zhang, Jili
    DESALINATION AND WATER TREATMENT, 2016, 57 (21) : 9993 - 10002
  • [30] EXPERIMENTAL STUDY OF HEAT TRANSFER CHARACTERISTICS FOR HORIZONTAL-TUBE FALLING FILM EVAPORATION
    Mu, Xingsen
    Yang, Yong
    Shen, Shengqiang
    Liang, Gangtao
    Gong, Luyuan
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, 2012, VOL 2, 2012, : 865 - 871