First test measurements of a 64k pixel readout chip working in single photon counting mode

被引:82
作者
Llopart, X [1 ]
Campbell, M [1 ]
机构
[1] CERN, CH-1211 Geneva 23, Switzerland
关键词
photon counting; pixel; CMOS; X-rays; medipix;
D O I
10.1016/S0168-9002(03)01565-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Medipix2 chip is a pixel detector readout chip consisting of 256 x 256 identical elements, each working in single photon counting mode for positive or negative input charge signals. The chip is designed and manufactured in a six-metal 0.25 mum CMOS technology. This paper describes several electrical measurements which have been carried out on the chip prior to detector bump bonding using a dedicated readout system. Threshold linearity and variation has been measured for both electron and hole collection. The noise is similar to100e(-) RMS and the threshold can be adjusted to similar to120e(-) RMS for both polarities. The minimum operating threshold is similar to1000e(-.) (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 5 条
  • [1] BELLO DS, 2002, IWORID2002 AMST P
  • [2] BERTOLUCCI, 2002, IEEE NUCL SCI S MED
  • [3] BERTOLUCCI, 2001, IEEE NUCL SCI S MED
  • [4] Medipix2:: a 64-k pixel readout chip with 55 μm square elements working in single photon counting mode
    Llopart, X
    Campbell, M
    Dinapoli, R
    Segundo, DS
    Pemigotti, E
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2279 - 2283
  • [5] MIKULEV B, 2002, SAMB 2 C 27 29 MAY T