Adherent octacalciumphosphate coating on titanium alloy using modulated electrochemical deposition method

被引:85
作者
Lin, SJ [1 ]
LeGeros, RZ [1 ]
LeGeros, JP [1 ]
机构
[1] NYU, Coll Dent, Dept Biomat & Biomimet, New York, NY 10010 USA
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A | 2003年 / 66A卷 / 04期
关键词
octacalciumphosphate; hydroxyapatite; coating; electrochemical deposition;
D O I
10.1002/jbm.a.10072
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Our aims in this study were (1) to develop an electrochemical method of depositing adherent octacalciumphosphate (OCP) and other calcium phosphate coatings on titanium alloy (Ti6Al4V) substrates of different shapes and surface preparations, (2) to determine the properties of the coating (composition, morphology, thickness, dissolution), and (3) to observe transformation of OCP to carbonatehydroxyapatite (CHA) in simulated body fluid (SBF). Titanium (Ti)-alloy plates, tensile bars with four types of surfaces (grit-blasted with apatitic abrasive, chemically textured, arc-deposited, and Co-Cr-beaded) and dissolution cylinders were electrochemically coated with the use of modulated pulse time electric fields programmed with a custom-made dual microprocessor. Modulated electrochemical deposition (MECD) was carried out with pH and temperature conditions favorable for OCP formation. Coatings were characterized using X-ray diffraction, FT-IR, scanning electron microscopy, tensile strength tests, and solubility tests. XRD and FT-IR analyses showed that pure, uniform OCP coatings were produced on Ti6Al4V surfaces with coating-to-substrate tensile strengths greater than 7000 psi. Coatings on Ti arc-deposited surfaces, chemically textured surfaces, and Co-Cr-beaded surfaces all gave tensile strengths ranging from 5000 to 7000 psi, with no coating shadows in the crevices. Dissolution of OCP coating in 100 mL of 0.1 M Tris buffer solution was determined from the amount of calcium (Ca) released onto the buffer, which was 7.7 +/- 1.0 ppm Ca at pH 7.3 after 4 h, and 22 -/+ 1.4 ppm Ca at pH 3 after 2 h. We found that OCP crystal size can be controlled by the current density and relative pulse time modulation. Our study demonstrated the following: (1) Highly adherent calcium phosphate (e.g., OCP) coating of uniform compositions (e.g., OCP) on Ti-alloy substrates can be obtained at low temperatures with the use of MECD by optimizing pulse time modulation of the electric field, reaction pH, temperature, and electrolyte composition; and (2) OCP readily transforms to CHA when exposed to SBF. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:819 / 828
页数:10
相关论文
共 42 条
[1]  
ASTM E, 2001, 2001 ANN BOOK ASTM S
[2]   CELL-MEDIATED EXTRACELLULAR ACIDIFICATION AND BONE-RESORPTION - EVIDENCE FOR A LOW PH IN RESORBING LACUNAE AND LOCALIZATION OF A 100-KD LYSOSOMAL MEMBRANE-PROTEIN AT THE OSTEOCLAST RUFFLED BORDER [J].
BARON, R ;
NEFF, L ;
LOUVARD, D ;
COURTOY, PJ .
JOURNAL OF CELL BIOLOGY, 1985, 101 (06) :2210-2222
[3]  
Brown W E, 1987, Adv Dent Res, V1, P306
[4]   Effects of hydroxylapatite coating crystallinity on biosolubility, cell attachment efficiency and proliferation in vitro [J].
Chou, L ;
Marek, B ;
Wagner, WR .
BIOMATERIALS, 1999, 20 (10) :977-985
[5]   HYDROXYLAPATITE COATING OF POROUS IMPLANTS IMPROVES BONE INGROWTH AND INTERFACE ATTACHMENT STRENGTH [J].
COOK, SD ;
THOMAS, KA ;
DALTON, JE ;
VOLKMAN, TK ;
WHITECLOUD, TS ;
KAY, JF .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (08) :989-1001
[6]  
DACULSI G, 1990, SCANNING MICROSCOPY, V4, P309
[7]   IN-VIVO MECHANICAL AND HISTOLOGICAL CHARACTERISTICS OF HA-COATED IMPLANTS VARY WITH COATING VENDOR [J].
DALTON, JE ;
COOK, SD .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (02) :239-245
[8]  
DASILVA MHP, 1998, BIOCERAMICS, V11, P223
[9]  
DEGROOT K, 1998, BIOCERAMICS, V11, P41
[10]  
DEGROOT K, 1987, HIGH TECH CERAMICS, P381