Cardiac output measured by electrical velocimetry in the CT suite correlates with coronary artery enhancement: A feasibility study

被引:12
作者
Flinck, Marianne [1 ,2 ]
Graden, Asa [1 ,2 ]
Milde, Helen [1 ,2 ]
Flinck, Agneta [1 ,2 ]
Hellstrom, Mikael [1 ,2 ]
Bjork, Jonas [3 ]
Nyman, Ulf [4 ]
机构
[1] Gothenburg Univ, Dept Radiol, Sahlgrenska Univ Hosp, S-41124 Gothenburg, Sweden
[2] Gothenburg Univ, Sahlgrenska Acad, S-41124 Gothenburg, Sweden
[3] Univ Lund Hosp, Competence Ctr Clin Res, S-22185 Lund, Sweden
[4] Lund Univ, Dept Radiol, SE-23185 Lasarettet Trelleborg, Trelleborg, Sweden
关键词
Contrast enhancement; coronary angiography; contrast medium-induced nephropathy; CONTRAST-INDUCED NEPHROPATHY; IMPEDANCE CARDIOGRAPHY; COMPUTED-TOMOGRAPHY; BODY-WEIGHT; THERMODILUTION; PREDICTION; RISK; EPIDEMIOLOGY; BIOIMPEDANCE; METAANALYSIS;
D O I
10.3109/02841851.2010.503663
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Cardiac output (CO) is inversely related to vascular contrast medium (CM) enhancement during computed tomography (CT). Impedance cardiography with a new technique, electrical velocimetry (EV), may create opportunities to measure CO pre-examination for adaptation of CM injection parameters. Purpose: To relate CO EV measured by radiology staff to aortic attenuation as a measure of coronary artery attenuation during CT coronary angiography (CTCA), and to formulate a tentative statistical model to adapt CM injection parameters to CO. Material and Methods: CO EV was measured immediately before 100 kVp CTCA (64-multirow detector) in 27 patients with presumed coronary artery disease. For CTCA, 260 mg I/kg (maximum dosage weight: 8090 kg for womenmen) was injected intravenously during 12 s. Simple linear regression analysis was performed to explore the correlation between aortic attenuation (Hounsfield units, HU) and body weight, the influence of CO EV on aortic attenuation adjusted to injected CM dose rate (HU per mg Ikgs), and to establish a tentative formula on how to adapt CM injection parameters to CO EV and desired aortic attenuation. Results: The correlation between aortic attenuation and body weight was weak and non-significant (r --0.14 after outlier exclusion). A significant negative correlation (r --0.63) was found between aortic attenuation adjusted to injected CM dose rate (HU per mg Ikgs) and CO EV. The resulting formula, CM dose rate = CO EV x (aortic attenuation -240)55, made it possible to calculate CM volumes and injection rates at various COs and, for example, the present mean aortic attenuation (438 HU), injection time (12 s), CM concentration (320 mg Iml), and a certain body weight. Conclusion: EV makes it possible to measure CO in the CT suite before vascular examinations. Hence, CM doses may be decreased in low CO states to reduce the risk of CM-induced nephropathy without jeopardizing diagnostic quality and may be increased in high CO states to avoid poor enhancement.
引用
收藏
页码:895 / 902
页数:8
相关论文
共 26 条
[1]   Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight [J].
Awai, K ;
Hiraishi, K ;
Hori, S .
RADIOLOGY, 2004, 230 (01) :142-150
[2]   Scan and contrast administration principles of MDCT [J].
Bae, KT ;
Heiken, JP .
EUROPEAN RADIOLOGY, 2005, 15 :E46-E59
[3]   Aortic and hepatic contrast medium enhancement at CT part II. Effect of reduced cardiac output in a porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :657-662
[4]   Aortic and hepatic contrast medium enhancement at CT part I. Prediction with a computer model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :647-655
[5]   Contrast enhancement in cardiovascular MDCT: Effect of body weight, height, body surface area, body mass index, and obesity [J].
Bae, Kyongtae T. ;
Seeck, Brian A. ;
Hildebolt, Charles F. ;
Tao, Cheng ;
Zhu, Fang ;
Kanematsu, Masayuki ;
Woodard, Pamela K. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (03) :777-784
[6]  
Bernstein DP, 2003, U.S. Patent, Patent No. [6511438, 6,511,438]
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]   A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[9]   Use of high-concentration contrast media in multi pie-detector-row CT: principles and rationale [J].
Fleischmann, D .
EUROPEAN RADIOLOGY, 2003, 13 (Suppl 5) :M14-M20
[10]   Influence of cardiac hemodynamic parameters on coronary artery opacification with 64-slice computed tomography [J].
Husmann, L ;
Alkadhi, H ;
Boehm, T ;
Leschka, S ;
Schepis, T ;
Koepfli, P ;
Desbiolles, L ;
Marincek, B ;
Kaufmann, PA ;
Wildermuth, S .
EUROPEAN RADIOLOGY, 2006, 16 (05) :1111-1116