Quantitative Analysis of Fentanyl and Six Fentanyl Analogs in Postmortem Specimens by UHPLC-MS-MS

被引:36
作者
Kahl, Joseph H. [1 ]
Gonyea, Jennifer [1 ]
Humphrey, Susan M. [1 ]
Hime, George W. [1 ]
Boland, Diane M. [1 ]
机构
[1] Miami Dade Med Examiner Dept, 1851 NW 10th Ave, Miami, FL 33136 USA
关键词
WHOLE-BLOOD; LC-MS/MS; DRUG; FATALITY; DEATHS;
D O I
10.1093/jat/bky054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Since 2013, opioid-related deaths have increased in Miami-Dade County, FL due to fentanyl and fentanyl analogs in the local heroin supply. From 2014 to 2015, a near 600% increase in fentanyl and fentanyl analog-related deaths was observed, followed by another 200% increase in 2016. In addition to fentanyl, six fentanyl analogs were identified in this time period: beta-hydroxythiofentanyl, acetyl fentanyl, furanyl fentanyl, carfentanil, butyryl fentanyl and para-fluoroisobutyryl fentanyl. As a result, an analytical method to quantify these compounds in postmortem biological fluids and tissues using solid-phase extraction with analysis by ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS-MS) was developed and validated. All analytes except carfentanil were linear from 1 to 50 ng/mL with a limit of detection (LOD) of 0.5 ng/mL; carfentanil was linear from 0.2 to 10 ng/mL with a LOD of 0.1 ng/mL. For all analytes, bias was within +/- 14%, intra- and inter-day precision were <= 5% and extraction efficiency was >87%. Dilution integrity was assessed at 1:1, 1:4 and 1:9 (v/v) ratios; percent error from target was <12% for all analytes. No exogenous interferences were observed. Analytes were stable in preserved whole blood stored at 4 degrees C for 9 months; extracted samples were stable in the refrigerated autosampler (15 degrees C) for up to 72 h. The ability to distinguish the isomer pairs isobutyryl/butyryl fentanyl and p-fluoroisobutyryl/p-fluorobutyryl fentanyl is achieved by this method. The method was applied to 312 cases in which fentanyl and/or fentanyl analogs were previously identified. Postmortem concentrations in blood ranged from <0.2 to 0.73 ng/mL for carfentanil and from 30.6 to 91.7 ng/mL for p-fluoroisobutyryl fentanyl in cases in which these analytes were listed as the sole cause of death.
引用
收藏
页码:570 / 580
页数:11
相关论文
共 35 条
  • [1] Fentanyl-associated Fatalities Among Illicit Drug Users in Wayne County, Michigan (July 2005-May 2006)
    Algren D.A.
    Monteilh C.P.
    Punja M.
    Schier J.G.
    Belson M.
    Hepler B.R.
    Schmidt C.J.
    Miller C.E.
    Patel M.
    Paulozzi L.J.
    Straetemans M.
    Rubin C.
    [J]. Journal of Medical Toxicology, 2013, 9 (1) : 106 - 115
  • [3] [Anonymous], 2008, NAT FOR LAB INF SYST
  • [4] [Anonymous], 2017, 4 FLUOR 4 FIBF CRIT
  • [5] Key aspects of analytical method validation and linearity evaluation
    Araujo, Pedro
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (23): : 2224 - 2234
  • [6] Opioid intoxications involving butyrfentanyl, 4-fluorobutyrfentanyl, and fentanyl from the Swedish STRIDA project
    Backberg, Matilda
    Beck, Olof
    Jonsson, Karl-Henrik
    Helander, Anders
    [J]. CLINICAL TOXICOLOGY, 2015, 53 (07) : 609 - 617
  • [7] Centers for Disease Control and Prevention, NAT VIT STAT SYST MO
  • [8] Fatal Intoxication with Acetyl Fentanyl
    Cunningham, Susan M.
    Haikal, Nabila A.
    Kraner, James C.
    [J]. JOURNAL OF FORENSIC SCIENCES, 2016, 61 : S276 - S280
  • [9] Dolan JW, 2009, LC GC N AM, V27, P534
  • [10] An Acute Ocfentanil Fatality: A Case Report with Postmortem Concentrations
    Dussy, F. E.
    Hangartner, S.
    Hamberg, C.
    Berchtold, C.
    Scherer, U.
    Schlotterbeck, G.
    Wyler, D.
    Briellmann, T. A.
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2016, 40 (09) : 761 - 766