Performance improvement of double-pass solar air heater - A state of art of review

被引:76
作者
Alam, Tabish [1 ]
Kim, Man-Hoe [1 ]
机构
[1] Kyungpook Natl Univ, Sch Mech Engn, Daegu, South Korea
关键词
Double-pass solar air heater; Packed bed; Recycle operation; Extended surface; Renewable energy; FLAT-PLATE COLLECTOR; FRICTION FACTOR CORRELATIONS; EXPANDED METAL MESH; ARTIFICIAL ROUGHNESS; THERMAL PERFORMANCE; TRANSFER ENHANCEMENT; PACKED-BED; WIRE MESH; EXTERNAL RECYCLE; RECTANGULAR DUCT;
D O I
10.1016/j.rser.2017.05.087
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents a comprehensive literature review of the various heat transfer techniques used to increase the performance of double-pass solar air heaters (SAHs). The heat transfer from absorber plate to air can be improved by increasing the convective heat transfer coefficient, the heat transfer area and by reducing thermal losses. These methodologies have guided the design and development of double-pass SAHs, and the results of several experimental studies show that double pass SAHs achieve better performance than single-pass SAHs. Literatures on double-pass SAHs have been reviewed to understand the different techniques used for performance improvement. The different operating and system parameters have been categorized to understand their performance behavior. The literature also reveals that numbers of techniques have been employed to improve heat transfer. These techniques include the incorporation of various features into the SAH design, such as extended surfaces, corrugated surfaces, artificial roughness, and packed beds. Furthermore, it is found that packed bed increase the heat transfer rate along with reduction in losses to environment because insolation is absorbed in the depth of packing material cause to lower the top layer temperature and, thereby, improvement in thermal losses.
引用
收藏
页码:779 / 793
页数:15
相关论文
共 98 条
[1]   CALCULATION OF THE TOP LOSS COEFFICIENT OF A FLAT-PLATE COLLECTOR [J].
AGARWAL, VK ;
LARSON, DC .
SOLAR ENERGY, 1981, 27 (01) :69-71
[2]   Approximate method for computation of glass cover temperature and top heat-loss coefficient of solar collectors with single glazing [J].
Akhtar, N ;
Mullick, SC .
SOLAR ENERGY, 1999, 66 (05) :349-354
[3]   A critical review on artificial roughness provided in rectangular solar air heater duct [J].
Alam, Tabish ;
Kim, Man-Hoe .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 69 :387-400
[4]   Numerical study on thermal hydraulic performance improvement in solar air heater duct with semi ellipse shaped obstacles [J].
Alam, Tabish ;
Kim, Man-Hoe .
ENERGY, 2016, 112 :588-598
[5]   Effect of circularity of perforation holes in V-shaped blockages on heat transfer and friction characteristics of rectangular solar air heater duct [J].
Alam, Tabish ;
Saini, R. P. ;
Saini, J. S. .
ENERGY CONVERSION AND MANAGEMENT, 2014, 86 :952-963
[6]   Experimental investigation on heat transfer enhancement due to V-shaped perforated blocks in a rectangular duct of solar air heater [J].
Alam, Tabish ;
Saini, R. P. ;
Saini, J. S. .
ENERGY CONVERSION AND MANAGEMENT, 2014, 81 :374-383
[7]   Use of turbulators for heat transfer augmentation in an air duct - A review [J].
Alam, Tabish ;
Saini, R. P. ;
Saini, J. S. .
RENEWABLE ENERGY, 2014, 62 :689-715
[8]   Single and double pass solar air heaters with wire mesh as packing bed [J].
Aldabbagh, L. B. Y. ;
Egelioglu, F. ;
Ilkan, M. .
ENERGY, 2010, 35 (09) :3783-3787
[9]  
[Anonymous], RENEW ENERGY
[10]   Performance characteristics of solar air heater with surface mounted obstacles [J].
Bekele, Adisu ;
Mishra, Manish ;
Dutta, Sushanta .
ENERGY CONVERSION AND MANAGEMENT, 2014, 85 :603-611