Development of a Rapid Screening Test for Listeria monocytogenes in Raw Chicken Meat Using Loop-Mediated Isothermal Amplification (LAMP) and Lateral Flow Dipstick (LFD)

被引:23
作者
Wachiralurpan, Sirirat [1 ]
Sriyapai, Thayat [2 ]
Areekit, Supatra [3 ]
Kaewphinit, Thongchai [3 ]
Sriyapai, Pichapak [4 ]
Santiwatanakul, Somchai [5 ]
Chansiri, Kosum [1 ]
机构
[1] Srinakharinwirot Univ, Dept Biochem, Fac Med, Sukhumvit 23, Bangkok 10110, Thailand
[2] Srinakharinwirot Univ, Fac Environm Culture & Ecotourism, Sukhumvit 23, Bangkok 10110, Thailand
[3] Srinakharinwirot Univ, Innovat Learning Ctr, Sukhumvit 23, Bangkok 10110, Thailand
[4] Srinakharinwirot Univ, Dept Biol, Fac Sci, Sukhumvit 23, Bangkok 10110, Thailand
[5] Srinakharinwirot Univ, Dept Pathol, Fac Med, Sukhumvit 23, Bangkok 10110, Thailand
关键词
L; monocytogenes; plcB gene; hly gene; Loop-mediated isothermal amplification (LAMP); Lateral flow dipstick (LFD); REAL-TIME PCR; QUANTITATIVE DETECTION; ASSAY; MILK; STRAINS; PRIMERS; SAMPLES; SYSTEM; GENES; FOOD;
D O I
10.1007/s12161-017-0949-4
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A loop-mediated isothermal amplification and lateral flow dipstick (LAMP-LFD) protocol was established for the rapid detection of the foodborne pathogen Listeria monocytogenes based on detection of the phosphatidylcholine-phospholipase C gene (plcB). The LAMP-LFD method achieved results within 90 min and consisted of a one-step DNA extraction followed by LAMP and LFD. The detection limits of the assay using L. monocytogenes purified genomic DNA or cells from a pure culture were 800 fg and 2.82 CFU mL(-1), respectively. The specificity test revealed that the method exhibited no cross-reactivity with other Listeria species (Listeria innocua DMST 9011, Listeria ivanovii DMST 9012, Listeria welshimeri DMST 20559) or non-Listeria spp. (Salmonella ssp., Shigella spp., Campylobacter spp., Escherichia coli ATCC 25922, Bacillus cereus, Staphylococcus aureus ATCC 25923, Pseudomonas aeruginosa ATCC 27853, Micrococcus luteus, Citrobacter diversus, Serratia marcescens, Enterobacter aerogenes, and Klebsiella oxytoca). Compared to standard culture analysis, the specificity, sensitivity, and accuracy of the LAMP-LFD method in tests of 200 raw chicken meat samples were 100, 90.20, and 97.50%, respectively. Thus, LAMP-LFD is a promising point-of-care diagnosis tool for decision-making for controlling of L. monocytogenes-contaminated food products, decreasing mortality rates, and improving the quality of life.
引用
收藏
页码:3763 / 3772
页数:10
相关论文
共 50 条
[21]   Rapid Detection of Salmonella and Listeria monocytogenes in Fresh Beef Using Loop-Mediated Isothermal Amplification [J].
Wang, Xiaoran ;
Jia, Kaixiang ;
Ran, Jinrong ;
Du, Yangyang ;
Yu, Xiaoying ;
Cao, Xuefeng ;
Peng, Lianci ;
Chen, Weifeng ;
Fang, Rendong ;
Li, Zhiwei .
FOODBORNE PATHOGENS AND DISEASE, 2025,
[22]   Evaluation of a loop-mediated isothermal amplification (LAMP) method for rapid on-site detection of horse meat [J].
Aartse, Aafke ;
Scholtens, Ingrid M. J. ;
van der A, Hans J. G. ;
Boersma-Greve, Monique M. ;
Prins, Theo W. ;
van Ginkel, Leen A. ;
Kok, Esther J. ;
Bovee, Toine F. H. .
FOOD CONTROL, 2017, 81 :9-15
[23]   Development of loop-mediated isothermal amplification combined with a chromatographic lateral-flow dipstick for rapid detection of Chattonella marina [J].
Qin, Yue ;
Chen, Guofu ;
Zhang, Chunyun ;
Wang, Yuanyuan ;
Zhou, Jin .
HARMFUL ALGAE, 2019, 89
[24]   Novel high-performance detection of Raillietina echinobothrida, Raillietina tetragona, and Raillietina cesticillus using loop-mediated isothermal amplification coupled with a lateral flow dipstick (LAMP-LFD) [J].
Panich, Wasin ;
Tejangkura, Thanawan ;
Chontananarth, Thapana .
VETERINARY PARASITOLOGY, 2021, 292
[25]   Development of a propidium monoazide treatment combined with loop-mediated isothermal amplification (PMA-LAMP) assay for rapid detection of viable Listeria monocytogenes [J].
Wan, Cuixiang ;
Yang, Youjun ;
Xu, Hengyi ;
Aguilar, Zoraida P. ;
Liu, Chunmei ;
Lai, Weihua ;
Xiong, Yonghua ;
Xu, Feng ;
Wei, Hua .
INTERNATIONAL JOURNAL OF FOOD SCIENCE AND TECHNOLOGY, 2012, 47 (11) :2460-2467
[26]   Rapid Screening for Salmonella in Raw Pet Food by Loop-Mediated Isothermal Amplification [J].
Domesle, Kelly J. ;
Young, Shenia R. ;
Ge, Beilei .
JOURNAL OF FOOD PROTECTION, 2021, 84 (03) :399-407
[27]   Development of a loop-mediated isothermal amplification assay for detecting Listeria monocytogenes prfA in milk [J].
Ae-Ri Cho ;
Hee-Jin Dong ;
Kun-Ho Seo ;
Seongbeom Cho .
Food Science and Biotechnology, 2014, 23 :467-474
[28]   Development of a novel visual assay for ultrasensitive detection of Listeria monocytogenes in milk and chicken meat harnessing helix loop-mediated isothermal amplification (HAMP) [J].
Prasad, M. C. B. ;
Milton, A. A. P. ;
Menon, V. K. ;
Srinivas, K. ;
Bhargavi, D. ;
Das, S. ;
Ghatak, S. ;
Vineesha, S. L. ;
Sunil, B. ;
Latha, C. ;
Priya, P. M. ;
Thomas, N. .
FOOD CONTROL, 2024, 155
[29]   Rapid and Sensitive Detection of Vibrio alginolyticus by Loop-Mediated Isothermal Amplification Combined with a Lateral Flow Dipstick Targeted to the rpoX Gene [J].
Plaon, Saranya ;
Longyant, Siwaporn ;
Sithigorngul, Paisarn ;
Chaivisuthangkura, Parin .
JOURNAL OF AQUATIC ANIMAL HEALTH, 2015, 27 (03) :156-163
[30]   Rapid Detection of Clostridium botulinum in Food Using Loop-Mediated Isothermal Amplification (LAMP) [J].
Chen, Yufei ;
Li, Hao ;
Yang, Liu ;
Wang, Lei ;
Sun, Ruyi ;
Shearer, Julia E. S. ;
Sun, Fengjie .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (09)