A multi-scale stopping criterion for MLEM reconstructions in PET

被引:6
作者
Bissantz, Nicolai [1 ,3 ]
Mair, Bernard A. [2 ]
Munk, Axel [3 ]
机构
[1] Ruhr Univ Bochum, Dept Math, Bochum, Germany
[2] Univ Florida, Dept Math, Gainesville, FL USA
[3] Univ Gottingen, Inst Math Stochast, Gottingen, Germany
来源
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6 | 2006年
关键词
D O I
10.1109/NSSMIC.2006.353726
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper we propose and test a new method for terminating the maximum likelihood expectation maximization algorithm for reconstructing positron emission tomography images. The method is based on a stochastic multiresolution analysis which involves all partial sums (scales) of normalized differences between the projected images and the detector data for each row of the sinogram. Previous methods involved only the single total sum of these differences for all detectors. Our method is theoretically founded on recent results from probability theory on the almost sure behaviour of the maximum of the partial sum process for Poisson data. Preliminary tests indicate that this method produces predictions for the optimal stopping iterations which are robust relative to modeling errors in the system matrix and has a signal-to-noise ratio which is 80% of the maximal SNR available from the MLEM iterates.
引用
收藏
页码:3376 / 3379
页数:4
相关论文
共 9 条
[1]   Globally convergent image reconstruction for emission tomography using relaxed ordered subsets algorithms [J].
Ahn, S ;
Fessler, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (05) :613-626
[2]   A CROSS-VALIDATION PROCEDURE FOR STOPPING THE EM ALGORITHM AND DECONVOLUTION OF NEUTRON DEPTH PROFILING SPECTRA [J].
COAKLEY, KJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (01) :9-15
[3]   FAST MLE FOR SPECT USING AN INTERMEDIATE POLAR REPRESENTATION AND A STOPPING CRITERION [J].
HEBERT, T ;
LEAHY, R ;
SINGH, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :615-619
[4]   ACCELERATED IMAGE-RECONSTRUCTION USING ORDERED SUBSETS OF PROJECTION DATA [J].
HUDSON, HM ;
LARKIN, RS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) :601-609
[5]  
KONTAXAKIS GN, 1996, IEEE C ENG MED BIOL, P848
[6]   FEASIBLE IMAGES AND PRACTICAL STOPPING RULES FOR ITERATIVE ALGORITHMS IN EMISSION TOMOGRAPHY [J].
LLACER, J ;
VEKLEROV, E .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1989, 8 (02) :186-193
[7]  
Shepp L A, 1982, IEEE Trans Med Imaging, V1, P113, DOI 10.1109/TMI.1982.4307558
[8]   On a conjecture of Revesz and its analogue for renewal processes [J].
Steinebach, J .
ASYMPTOTIC METHODS IN PROBABILITY AND STATISTICS: A VOLUME IN HONOUR OF MIKLOS CSORGO, 1998, :311-322
[9]   STOPPING RULE FOR THE MLE ALGORITHM BASED ON STATISTICAL HYPOTHESIS-TESTING [J].
VEKLEROV, E ;
LLACER, J .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1987, 6 (04) :313-319