Retrieved Highly Crosslinked UHMWPE Acetabular Liners Have Similar Wear Damage as Conventional UHMWPE

被引:31
|
作者
Schroder, David T. [2 ]
Kelly, Natalie H. [1 ]
Wright, Timothy M. [1 ]
Parks, Michael L. [2 ]
机构
[1] Hosp Special Surg, Dept Biomech, New York, NY 10021 USA
[2] Hosp Special Surg, Adult Reconstruct & Joint Replacement Div, New York, NY 10021 USA
关键词
TOTAL HIP; POLYETHYLENE;
D O I
10.1007/s11999-010-1552-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Highly crosslinked UHMWPE is associated with increased wear resistance in hip simulator and clinical studies. Laboratory and case studies, however, have described rim fracture in crosslinked acetabular liners. Controversy exists, therefore, on the relative merits of crosslinked liners over conventional liners in terms of wear performance versus resistance to fatigue cracking. Questions/purposes We asked whether crosslinked liners would show less surface damage than conventional liners but would be more susceptible to fatigue damage. Methods We examined 36 conventional UHMWPE and 39 crosslinked UHMWPE retrieved implants with similar patient demographics and identical design for evidence of wear damage, including articular surface damage, impingement, screw-hole creep, and rim cracks. Results We observed no difference in wear damage scores for the two liners. Conventional liners more frequently impinged but were more often elevated with smaller head sizes. We observed creep in approximately 70% of both types of liners. Incipient rim cracks were found in five crosslinked liners, and one liner had a rim fracture. Only one conventional liner had an incipient rim crack. Conclusions Contrary to our expectation, damage was similar between crosslinked and conventional UHMWPE liners. Moreover, the 15% occurrence (six of 39) of incipient or complete fractures in crosslinked liners as compared with a 3% occurrence (one of 36) in conventional liners may have implications for the long-term performance of crosslinked liners. Longer-term studies will be necessary to establish the fate of rim cracks and thus the overall clinical fatigue performance of crosslinked liners.
引用
收藏
页码:387 / 394
页数:8
相关论文
共 22 条
  • [1] A novel method to measure rim deformation in UHMWPE acetabular liners
    Partridge, Susan
    Buckley, Paige
    de Boer, Greg
    Williams, Sophie
    MEDICAL ENGINEERING & PHYSICS, 2018, 59 : 56 - 62
  • [2] Comparison of Polyethylene Wear between Highly Cross linked and Annealed UHMWPE and Conventional UHMWPE against Ceramic Heads in Total Hip Arthroplasty
    Sato, Taishi
    Nakashima, Yasuharu
    Akiyama, Mio
    Yamamoto, Takuaki
    Mawatari, Taro
    Itokawa, Takashi
    Ohishi, Masanobu
    Motomura, Goro
    Hirata, Masanobu
    Iwamoto, Yukihide
    BIOCERAMICS 24, 2013, 529-530 : 279 - 284
  • [3] Development of a model for testing third body wear of UHMWPE acetabular components
    Bragdon, CR
    O'Connor, D
    Muratoglu, OK
    Harris, WH
    CROSSLINKED AND THERMALLLY TREATED ULTRA-HIGH MOLECULAR WEIGHT POLYETHYLENE FOR JOINT REPLACEMENTS, 2004, 1445 : 240 - 247
  • [4] Oxidation and other property changes of retrieved sequentially annealed UHMWPE acetabular and tibial bearings
    Reinitz, Steven D.
    Currier, Barbara H.
    Van Citters, Douglas W.
    Levine, Rayna A.
    Collier, John P.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2015, 103 (03) : 578 - 586
  • [5] A highly crosslinked UHMWPE for CR and PS total knee arthroplasties
    Wang, Aiguo
    Yau, Shi-Shen
    Essner, Aaron
    Herrera, Lizeth
    Manley, Michael
    Dumbleton, John
    JOURNAL OF ARTHROPLASTY, 2008, 23 (04) : 559 - 566
  • [6] Validation of a micro-CT technique for measuring volumetric wear in retrieved acetabular liners
    Bowden, AE
    Kurtz, SM
    Edidin, AA
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 75B (01) : 205 - 209
  • [7] The influence of plastic deformation on structure of highly crosslinked UHMWPE intended for endoprosthesis cups
    Maszybrocka, Joanna
    Cybo, Jerzy
    Cwajna, Jan
    Barylski, Adrian
    Czaja, Piotr
    STEREOLOGY AND IMAGE ANALYSIS IN MATERIAL SCIENCE, 2013, 197 : 13 - +
  • [8] Dual articulation retentive acetabular liners and wear: surface analysis of 40 retrieved polyethylene implants
    Adam, P
    Farizon, F
    Fessy, MH
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2005, 91 (07): : 627 - 636
  • [9] Thermal stabilization of highly crosslinked UHMWPE: A comparative study between annealed and remelted resins
    Ferroni, Daniela
    Quaglini, Virginio
    JOURNAL OF APPLIED BIOMATERIALS & BIOMECHANICS, 2010, 8 (02) : 82 - 88
  • [10] Variation of mechanical properties and oxidation with radiation dose and source in highly crosslinked remelted UHMWPE
    Fung, Mitchell
    Bowsher, John G.
    Van Citters, Douglas W.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 82 : 112 - 119