Modification of the tear function index and its use in the diagnosis of Sjogren's syndrome

被引:16
作者
Kaye, SB
Sims, G
Willoughby, C
Field, AE
Longman, L
Brown, MC
机构
[1] Royal Liverpool Univ Hosp, St Pauls Eye Unit, Liverpool L12 2AP, Merseyside, England
[2] Royal Liverpool Univ Hosp, Dept Oral Med, Liverpool L12 2AP, Merseyside, England
[3] Royal Liverpool Univ Hosp, Dept Clin Engn, Liverpool L12 2AP, Merseyside, England
关键词
D O I
10.1136/bjo.85.2.193
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background-The tear function index (TFI) has been shown to be of value in the diagnosis of patients suffering from Sjogren's syndrome. It is dependent, however, on introducing into the conjunctival fornix the correct concentration of fluorescein in at least one and a half times the normal tear volume. The stimulus and effect of this added volume on the tear dynamics is likely to vary between individuals. These factors, together with the method of performing the test, limit its general applicability. Aim-To devise a method of performing the TFT with less variability and more general applicability. To present a theoretical and in vitro assessment of the dynamics of the TFI. Method-The study was divided into three parts. The first part was to compare the results obtained using a prepared strip containing 1.3 mu1 of 0.5% fluorescein with the introduction of the same amount of fluorescein as a drop, The second part was to compare the results obtained with prepared strips with the standard method of performing the TFT, both with and without topical anaesthetic. The third part was an in vitro study of the rate of flow of graded volumes on a filter paper strip. 42 subjects with a diagnosis of Sjogren's syndrome according to the European criteria and 126 without Sjogren's syndrome were included. Results-There was no significant difference between the results obtained with a prepared strip and the introduction of 1.3 pi into the eye before performing the Schirmer's test and TFT (0.1<p<0.93). There was, likewise, no significant difference between using the prepared strips and the standard method of performing the TFI (0.36<p<0.93). There was, however, less interocular difference (p=0.01) and variability (p=0.001) using the prepared strips than using a drop of fluorescein. Patients with Sjogren's syndrome had mean TFIs of 11.7 and 8.61 with upper 95% confidence values of 15 and 12 without and with topical anaesthetic, respectively. The theoretical calculation of the TFI was similar to the observed values. The in vitro results allow the filter paper to be removed from the eye at any interval and to estimate the volume of tears that the filter paper was in contact with. Conclusion-The proposed method of performing the TFI is easy to perform, reliable, and therefore has general applicability for primary care and general practitioners. It allows the rapid identification of subjects who may be suffering from Sjogren's syndrome.
引用
收藏
页码:193 / 199
页数:7
相关论文
共 31 条
[1]   HUMAN TEAR LYSOZYME .2. QUANTITATIVE DETERMINATION WITH STANDARD SCHIRMER STRIPS [J].
BONAVIDA, B ;
SAPSE, AT .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1968, 66 (01) :70-&
[2]  
BRON A J, 1991, Eye (London), V5, P395
[3]   SCHIRMER TEST - A CLOSER LOOK [J].
CLINCH, TE ;
BENEDETTO, DA ;
FELBERG, NT ;
LAIBSON, PR .
ARCHIVES OF OPHTHALMOLOGY, 1983, 101 (09) :1383-1386
[4]   The establishment of a xerostomia clinic: A prospective study [J].
Field, EA ;
Longman, LP ;
Bucknall, R ;
Kaye, SB ;
Higham, SM ;
Edgar, WM .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1997, 35 (02) :96-103
[5]  
GILBARD JP, 1978, ARCH OPHTHALMOL-CHIC, V96, P677
[6]   DIAGNOSTIC-TESTS IN PATIENTS WITH SYMPTOMS OF KERATOCONJUNCTIVITIS SICCA [J].
GOREN, MB ;
GOREN, SB .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1988, 106 (05) :570-574
[7]  
HENDERSON JW, 1950, ARCH OPHTHALMOL-CHIC, V43, P224
[8]  
JORDAN A, 1980, OPHTHALMOLOGY, V87, P920
[9]   LACTOFERRIN LEVELS IN NORMAL HUMAN TEARS [J].
KIJLSTRA, A ;
JEURISSEN, SHM ;
KONING, KM .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1983, 67 (03) :199-202
[10]  
LAMBERTS DW, 1979, ARCH OPHTHALMOL-CHIC, V97, P1082