Application of polynomial regression and MILP for under-frequency load shedding scheme in islanded distribution system

被引:8
|
作者
Sarwar, Sohail [1 ]
Mokhlis, Hazlie [1 ]
Othman, Mohamadariff [1 ]
Shareef, Hussain [2 ]
Wang, Li [3 ]
Mansor, Nurulafiqah Nadzirah [1 ]
Khairuddin, Anis Salwa Mohd [1 ]
Mohamad, Hasmaini [4 ]
机构
[1] Univ Malaya, Fac Engn, Dept Elect Engn, Kuala Lumpur 50603, Malaysia
[2] United Arab Emirates Univ, Dept Elect Engn, Al Ain 155511, U Arab Emirates
[3] Natl Cheng Kung Univ, Dept Elect Engn, Tainan 70101, Taiwan
[4] Univ Teknol MARA, Sch Elect Engn, Shah Alam 40450, Malaysia
关键词
Frequency instability; Load priority; Mixed integer linear programming; Polynomial regression; System blackout; Under frequency load shedding; ENHANCEMENT;
D O I
10.1016/j.aej.2021.06.028
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Distributed Generation (DG) integration, especially based on renewable energy resources, has gained great attention by power utilities and frequently utilized in the electrical distribution systems. However, DG integration imposes some risks towards system stability which may lead to system blackouts. This mainly occurs when the grid is decoupled from a portion of the distribution system consisting DGs while the total load demand is greater than total DGs output power. In order to overcome this problem, load shedding technique can be adopted to stabilize the system frequency. However, existing load shedding techniques were unable to accurately estimate the power imbalance due the variation in system loading. This results in excessive/inadequate load shedding to stabilize the system frequency. Moreover, random selection of the loads without load prioritization might cause vital loads to be shed. Therefore, in this paper, a new load shedding strategy for islanded distribution system is proposed. Polynomial regression analysis estimates the power mismatch while MILP optimization estimates optimal load combination for shedding. Furthermore, load priority (i.e., vital, non-vital, and semi-vital) is also considered to avoid disconnecting vital loads. Efficiency of the proposed scheme is evaluated on three different test systems. Validation is performed by modelling the proposed load shedding on PSCAD/EMTDC software for dynamic analysis. From the results, it can be analyzed that the proposed technique is superior compared to other techniques proposed in the literature. (C) 2021 THE AUTHORS. Published by Elsevier BV on behalf of Faculty of Engineering, Alexandria University.
引用
收藏
页码:659 / 674
页数:16
相关论文
共 50 条
  • [31] Optimal Under-Frequency Load Shedding Setting at Altai-Uliastai Regional Power System, Mongolia
    Acosta, Martha N.
    Adiyabazar, Choidorj
    Gonzalez-Longatt, Francisco
    Andrade, Manuel A.
    Torres, Jose Rueda
    Vazquez, Ernesto
    Riquelme Santos, Jesus Manuel
    ENERGIES, 2020, 13 (20)
  • [32] Adaptive neuro-fuzzy inference system based under-frequency load shedding for Tamil Nadu
    Joshua, K. Paul
    Mohanalin, J.
    Christa, S. T. Jaya
    JOURNAL OF SUPERCOMPUTING, 2020, 76 (06): : 4184 - 4198
  • [33] Modified centralized ROCOF based load shedding scheme in an islanded distribution network
    Mokari-Bolhasan, Amin
    Seyedi, Heresh
    Mohammadi-ivatloo, Behnam
    Abapour, Saeed
    Ghasemzadeh, Saeed
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 62 : 806 - 815
  • [34] An optimal under-frequency load shedding strategy considering distributed generators and load static characteristics
    Liu, Zhipeng
    Wen, Fushuan
    Ledwich, Gerard
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2014, 24 (01): : 75 - 90
  • [35] Under-Frequency Load Shedding in Mongolia: Simulation Assessment Considering Inertia Scenarios
    Adiyabazar, Choidorj
    Acosta, Martha N.
    Gonzalez-Longatt, F.
    Rueda, J. L.
    Palensky, P.
    2020 IEEE 29TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2020, : 1256 - 1261
  • [36] Adaptive neuro-fuzzy inference system based under-frequency load shedding for Tamil Nadu
    K. Paul Joshua
    J. Mohanalin
    S. T. Jaya Christa
    The Journal of Supercomputing, 2020, 76 : 4184 - 4198
  • [37] Robust Under-Frequency Load Shedding With Electric Vehicles Under Wind Power and Commute Uncertainties
    Liu, Hui
    Pan, Houlin
    Wang, Ni
    Yousaf, Muhammad Zain
    Goh, Hui Hwang
    Rahman, Saifur
    IEEE TRANSACTIONS ON SMART GRID, 2022, 13 (05) : 3676 - 3687
  • [38] Influences of the Time Delay on the Control Effect of Under-frequency Load Shedding in Power Systems
    Li Ye
    Zhang Baohui
    Guan Zhe
    Bo Zhiqian
    2015 27TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2015, : 5182 - 5186
  • [39] Enhancing System Resilience: MILP Application for Efficient Load Reduction in Islanded Multi-Area Distribution Networks
    Sarwar, Sohail
    Merlin, Michael M. C.
    Kiprakis, Aristides
    2024 IEEE INDUSTRIAL ELECTRONICS AND APPLICATIONS CONFERENCE, IEACON 2024, 2024, : 25 - 30
  • [40] Under-Frequency Load Shedding in a Standalone Power System With Wind-Turbine Generators Using Fuzzy PSO
    Hong, Ying-Yi
    Hsiao, Chih-Yang
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (02) : 1140 - 1150