Aerosol generation during pulmonary function testing: Monitoring during different testing modalities

被引:1
作者
Wu, Joyce K. Y. [1 ,2 ]
Ryan, Clodagh M. [1 ,2 ]
Hiebert, Ryan J. [3 ]
Han, Ziwen [1 ]
Liu, Annie [1 ]
Jeong, Cheol-Heon [4 ]
Mubareka, Samira [3 ]
Evans, Greg J. [4 ]
Chow, Chung-Wai [1 ,2 ,4 ]
机构
[1] Univ Hlth Network, Dept Med, Div Respirol, Toronto, ON, Canada
[2] Univ Hlth Network, Toronto Gen Pulm Funct Lab, Toronto, ON, Canada
[3] Sunnybrook Med Ctr, Dept Lab Med & Pathobiol, Med Microbiol, Toronto, ON, Canada
[4] Univ Toronto, Southern Ontario Ctr Atmospher Aerosol Res, Toronto, ON, Canada
关键词
Aerosol generation; oscillometry; pulmonary function laboratory; spirometry; PARTICLE-SIZE; TRANSMISSION; RESTAURANT; SARS-COV-2; GUANGZHOU; CHINA;
D O I
10.1080/24745332.2021.1965926
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
RATIONALE: : Severe acute respiratory syndrome caused by coronavirus 2 (SARS-CoV-2) was declared a pandemic on March 11, 2020. Countries entered lockdown, restricting medical activities to essential services. Pulmonary function tests (PFT) are crucial for management of lung diseases. With limited data regarding aerosol generation and the risk of disease transmission during PFTs, many laboratories closed. Our objective is to quantify aerosol generation during different PFT modalities. METHODS: We measured aerosol particles in the 0.3-10.0 mu m range with an Optical Particle Sizer (Model 3330; TSI Incorporated) and collected bioaerosols to detect respiratory pathogens during clinically indicated PFTs at a hospital-based laboratory during 2 time points in 2020. RESULTS: We monitored 81 and 41 individual multi-modality PFT sessions in June/July and December, respectively. Slow vital capacity, forced vital capacity and diffusion capacity generated higher aerosol counts compared to pre- and post-test room levels although all modalities were lower than during talking or coughing. The aerosol sizes generated were primarily 2.5-10 mu m. Oscillometry generated higher overall concentrations than room sampling, also primarily in the 2.5-10 mu m aerosols. The bioaerosol filters revealed no respiratory viruses or bacteria. CONCLUSIONS: While PFT can generate aerosols, it is less than normal speech with the exception of PFT-induced coughing. Our findings suggest the risk of SARS-CoV-2 transmission is not increased and support the re-opening of PFT laboratories that adhere to universal masking, use of personal protective equipment and stringent infection control protocols. We strongly endorse adherence to public health guidelines in the operation of PFT laboratories.
引用
收藏
页码:229 / 236
页数:8
相关论文
共 50 条
  • [41] The Effect of Obesity on Pulmonary Function Testing Among the Jordanian Population
    Al-Qerem, Walid
    Gassar, Ezeddin Salem
    Al-Qirim, Rania
    Mohamed, Negia Abdullah Emtawel
    CURRENT RESPIRATORY MEDICINE REVIEWS, 2018, 14 (02) : 89 - 94
  • [42] Safety of pulmonary function testing: data from 20 years
    Roberts, Cara
    Ward, Simon
    Walsted, Emil
    Hull, James H.
    THORAX, 2018, 73 (04) : 385 - 387
  • [43] Pulmonary function testing in preoperative high-risk patients
    Eimer, Christine
    Urbaniak, Natalia
    Dempfle, Astrid
    Becher, Tobias
    Schaedler, Dirk
    Weiler, Norbert
    Frerichs, Inez
    PERIOPERATIVE MEDICINE, 2024, 13 (01)
  • [44] Pulmonary function testing in preoperative high-risk patients
    Christine Eimer
    Natalia Urbaniak
    Astrid Dempfle
    Tobias Becher
    Dirk Schädler
    Norbert Weiler
    Inéz Frerichs
    Perioperative Medicine, 13
  • [45] Dynamics of aerosol generation and flow during inhalation for improved in vitro-in vivo correlation (IVIVC) of pulmonary medicines
    Dorosz, Agata
    Moskal, Arkadiusz
    Sosnowski, Tomasz R.
    CHEMICAL AND PROCESS ENGINEERING-NEW FRONTIERS, 2023, 44 (04):
  • [46] Outcomes of patients with chronic obstructive pulmonary disease diagnosed with or without pulmonary function testing
    Gershon, Andrea
    Mecredy, Graham
    Croxford, Ruth
    To, Teresa
    Stanbrook, Matthew B.
    Aaron, Shawn D.
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2017, 189 (14) : E530 - E538
  • [47] A spirometry-based algorithm to direct lung function testing in the pulmonary function laboratory
    Glady, CA
    Aaron, SD
    Lunau, M
    Clinch, J
    Dales, RE
    CHEST, 2003, 123 (06) : 1939 - 1946
  • [48] Reasons for Referral for Pulmonary Function Testing: An Audit of 4 Adult Lung Function Laboratories
    Pretto, Jeffrey J.
    Brazzale, Danny J.
    Guy, Paul A.
    Goudge, Russell J.
    Hensley, Michael J.
    RESPIRATORY CARE, 2013, 58 (03) : 507 - 510
  • [49] Resumption of pulmonary function testing during the COVID-19 pandemic A Position Statement from the Canadian Thoracic Society and the Canadian Society of Respiratory Therapists
    Stanojevic, Sanja
    Beaucage, Francois
    Comondore, Vikram
    Faughnan, Marie
    Kovesi, Tom
    McCoy, Carolyn
    McParland, Colm
    Pawluski, David
    Refahi, Farzad
    Road, Jeremy
    Kooperberg, Micah
    CANADIAN JOURNAL OF RESPIRATORY CRITICAL CARE AND SLEEP MEDICINE, 2022, 6 (02) : 78 - 81
  • [50] Aerosol Generation During Bone-Sawing Procedures in Veterinary Autopsies
    Wenner, L.
    Pauli, U.
    Summermatter, K.
    Gantenbein, H.
    Vidondo, B.
    Posthaus, H.
    VETERINARY PATHOLOGY, 2017, 54 (03) : 425 - 436