Two-dimensional GEM imaging detector with delay-line readout

被引:41
|
作者
Guedes, GP
Breskin, A
Chechik, R [1 ]
Vartsky, D
Bar, D
Barbosa, AF
Marinho, PRB
机构
[1] Weizmann Inst Sci, Dept Particle Phys, IL-76100 Rehovot, Israel
[2] Soreq NRC, Yavne, Israel
[3] CBPF, BR-15022918 Rio De Janeiro, RJ, Brazil
关键词
GEM; gaseous imaging detector; delay-line readout; 2D readout;
D O I
10.1016/S0168-9002(03)02017-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A 100 x 100 mm(2) 2D imaging detector, based on a triple-GEM gaseous multiplier, striped x-y readout anode and discrete delay-line readout, is presented. The fast (2.1 ns tap(-1)) delay-line circuit was designed to match the anode-charge signal profile, namely its rise-time and length. The detector's imaging capability was systematically studied in Ar/CO2 (70/30) with 5.9 keV X-rays; x-y resolution of sigma = 0.05 and 0.1 mm for top and bottom anode strips, respectively, and integral non-linearity of similar to0.15% are demonstrated. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:473 / 483
页数:11
相关论文
共 50 条
  • [1] Study of delay-line readout for GEM detector
    Zhou, Yi
    Li, Cheng
    Sun, Yongjie
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 71 - 76
  • [2] An X-ray imaging device based on a GEM detector with delay-line readout
    Zhou Yi
    Li Cheng
    Sun Yong-Jie
    Shao Ming
    CHINESE PHYSICS C, 2010, 34 (01) : 78 - 82
  • [3] An X-ray imaging device based on a GEM detector with delay-line readout
    周意
    李澄
    孙勇杰
    邵明
    中国物理C, 2010, (01) : 78 - 82
  • [4] Research on the delay-line readout for GEM detectors
    Zhou Yi
    Li Cheng
    CHINESE PHYSICS C, 2008, 32 : 232 - 234
  • [5] A triple GEM detector with two-dimensional readout
    Ziegler, M
    Sievers, P
    Straumann, U
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2): : 260 - 263
  • [6] A MICROSTRIP DETECTOR WITH DELAY-LINE READOUT
    BARBOSA, AF
    RIEKEL, C
    WATTECAMPS, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 667 - 669
  • [7] Two-dimensional imaging triple-GEM detector with resistive anode readout
    Ju, X. D.
    Dong, M. Y.
    Zhao, Y. C.
    Zhou, C. X.
    Dong, J.
    Zhao, Y. B.
    Zhang, H. Y.
    OuYang, Q.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [8] A data acquisition system for two-dimensional position sensitive micropattern gas detectors with delay-line readout
    Hanu, A. R.
    Prestwich, W. V.
    Byun, S. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 780 : 33 - 39
  • [9] FPGA implementation of a delay-line readout system for a particle detector
    Seferiadis, G
    Pouchet, M
    Gough, MP
    MEASUREMENT, 2006, 39 (01) : 90 - 99
  • [10] Study of Delay-line Readout for Boron Coated Straw detector
    Yu, Hao
    Gong, Hui
    Wang, Yongqiang
    Wang, Xuewu
    Li, Jianmin
    Li, Yuanjing
    Kang, Kejun
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,