Study on the best heat transfer rate in thermal response test experiments with coaxial and U-pipe borehole heat exchangers

被引:30
作者
Morchio, Stefano [1 ]
Fossa, Marco [1 ]
Beier, Richard A. [2 ]
机构
[1] Univ Genoa, Dime Dept Mech Energy Management & Transportat En, Via Opera Pia 15, I-16145 Genoa, Italy
[2] Oklahoma State Univ, Div Engn Technol, Stillwater, OK 74078 USA
关键词
Ground source heat pumps; Coaxial pipe geometry; U-pipe BHE; Deep borehole heat exchanger; Ground thermal conductivity; Thermal response test; Geothermal gradient; VERTICAL TEMPERATURE PROFILES; DEEP BOREHOLE; NATURAL-CONVECTION; COUPLED HEAT; PERFORMANCE; RESISTANCE; EXTRACTION; SIMULATION; SYSTEMS; DESIGN;
D O I
10.1016/j.applthermaleng.2021.117621
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper concerns the modeling of vertical Borehole Heat Exchangers (BHEs) for Ground Source Heat Pump (GSHP) applications. Focus is devoted to the analyses of Thermal Response Test (TRT) simulations aimed at understanding the main factors that influence the ground thermal conductivity and the effective borehole thermal resistance estimations. The conventional infinite line-source (ILS) model does not include any influence of the external heat transfer rate on the BHE/ground property evaluation. Analyses of numerically simulated TRTs show this omission can sometimes produce an error in the estimate of the ground thermal conductivity. The error may be between +/- 10% and +/- 22% for coaxial boreholes (800 m depth), if the ground has a significant geothermal gradient. On the other hand, for single and double U-pipe BHEs the error is less than +/- 5% under similar conditions. The parameter q(ratio) is identified as an indicator of when the error is significant. This parameter is equal to the external heat rate (injection or extraction) divided by a natural heat rate that is related to the geothermal gradient. Errors greater than +/- 10% tend to occur for coaxial boreholes with a center-pipe fluid inlet when vertical bar q(ratio)vertical bar < 1. Under the same conditions but with the annulus as the fluid inlet, the error is less than +/- 6%.
引用
收藏
页数:17
相关论文
共 51 条
[1]  
Acuna J., 2013, DISTRIBUTED THERMAL
[2]   Distributed thermal response tests on pipe-in-pipe borehole heat exchangers [J].
Acuna, Jose ;
Palm, Bjorn .
APPLIED ENERGY, 2013, 109 :312-320
[3]  
[Anonymous], 2012, 11466 UNI, P107
[4]  
[Anonymous], 2015, ASHRAE Handbook of HVAC Applications
[5]  
[Anonymous], 1997, P 19 NZ GEOTH WORKSH
[6]   Analysis on Thermal Performance of Ground Heat Exchanger According to Design Type Based on Thermal Response Test [J].
Bae, Sang Mu ;
Nam, Yujin ;
Choi, Jong Min ;
Lee, Kwang Ho ;
Choi, Jae Sang .
ENERGIES, 2019, 12 (04)
[7]   Models of thermal response tests on deep coaxial borehole heat exchangers through multiple ground layers [J].
Beier, Richard A. ;
Fossa, Marco ;
Morchio, Stefano .
APPLIED THERMAL ENGINEERING, 2021, 184
[8]   Thermal response tests on deep borehole heat exchangers with geothermal gradient [J].
Beier, Richard A. .
APPLIED THERMAL ENGINEERING, 2020, 178
[9]   Transient heat transfer in a U-tube borehole heat exchanger [J].
Beier, Richard A. .
APPLIED THERMAL ENGINEERING, 2014, 62 (01) :256-266
[10]   Borehole resistance and vertical temperature profiles in coaxial borehole heat exchangers [J].
Beier, Richard A. ;
Acuna, Jose ;
Mogensen, Palne ;
Palm, Bjorn .
APPLIED ENERGY, 2013, 102 :665-675