Influence of nasal obstruction on auto-CPAP behaviour during sleep in sleep apnoea/hypopnoea syndrome

被引:15
作者
Lafond, C [1 ]
Sériès, F [1 ]
机构
[1] Univ Laval, Hop Laval, Unite Rech, Ctr Pneumol, Ste Foy, PQ G1V 4G5, Canada
关键词
sleep apnoea/hypopnoea syndrome; auto-CPAP; nasal resistance;
D O I
10.1136/thx.53.9.780
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background-Auto-CPAP machines have been developed to adapt automatically the positive pressure level to the required needs. The auto-CPAP response to transient nasal obstruction was tested during sleep in patients with sleep apnoea/hypopnoea syndrome (SAHS). Methods-Nasal obstruction was induced by local instillation of histamine. Fourteen nasal challenges were performed on eight patients, seven while the patients were on the "Morphee plus" apparatus and the other seven with the patients on the "Horizon" machine. Results-Nasal resistance increased initially by a mean (SD) of 166 (66)% during the trials with the "Morphee plus" and by 118 (44)% with the "Horizon" machine. The increase in nasal resistance was always accompanied by flow limitation with one exception. Mask pressure initially decreased to the minimal permitted value as nasal resistance increased with the "Morphee plus" device. A late increase of the positive pressure level occurred sometimes. Mask pressure did not change with increasing nasal resistance when the "Horizon" device was used. Conclusion-Neither the "Morphee plus" nor the "Horizon" device abolished flow limited breaths and resulting sleep fragmentation. We conclude that, despite the different algorithm of pressure changes, these auto-CPAP machines do not adequately respond to an acute increase in nasal resistance.
引用
收藏
页码:780 / 783
页数:4
相关论文
共 32 条
  • [21] Linear and nonlinear analysis of airflow recordings to help in sleep apnoea-hypopnoea syndrome diagnosis
    Gutierrez-Tobal, G. C.
    Hornero, R.
    Alvarez, D.
    Marcos, J. V.
    del Campo, F.
    PHYSIOLOGICAL MEASUREMENT, 2012, 33 (07) : 1261 - 1275
  • [22] Nasal continuous positive airway pressure with supplemental oxygen in coexistent sleep apnoea-hypopnoea syndrome and severe chronic obstructive pulmonary disease
    Sampol, G
    Sagales, MT
    Roca, A
    delaCalzada, MD
    Bofill, JM
    Morell, F
    EUROPEAN RESPIRATORY JOURNAL, 1996, 9 (01) : 111 - 116
  • [23] Sleep apnoea-hypopnoea syndrome in the obese and non-obese: clinical, polysomnographical and clinical characteristics
    Cuevas, Elena Martinez
    Pelaez, Carmen Munoz
    Carbajo, Estrella Ordax
    Eguia, Ana Isabel Navazo
    Vine, Lourdes Martin
    Jimeno, Aranzazu Prieto
    Alonso-Alvarez, Maria Luz
    ANALES DE PEDIATRIA, 2021, 95 (03): : 147 - 158
  • [24] Irregularity and Variability Analysis of Airflow Recordings to Facilitate the Diagnosis of Paediatric Sleep Apnoea-Hypopnoea Syndrome
    Barroso-Garcia, Veronica
    Cesar Gutierrez-Tobal, Gonzalo
    Kheirandish-Gozal, Leila
    Alvarez, Daniel
    Vaquerizo-Villar, Fernando
    Crespo, Andrea
    del Campo, Felix
    Gozal, David
    Hornero, Roberto
    ENTROPY, 2017, 19 (09)
  • [25] Accuracy of a novel auto-CPAP device to evaluate the residual apnea-hypopnea index in patients with obstructive sleep apnea
    Alberto Nigro, Carlos
    Gonzalez, Sergio
    Arce, Anabella
    Rosario Aragone, Maria
    Nigro, Luciana
    SLEEP AND BREATHING, 2015, 19 (02) : 569 - 578
  • [26] Accuracy of a novel auto-CPAP device to evaluate the residual apnea-hypopnea index in patients with obstructive sleep apnea
    Carlos Alberto Nigro
    Sergio González
    Anabella Arce
    María Rosario Aragone
    Luciana Nigro
    Sleep and Breathing, 2015, 19 : 569 - 578
  • [27] Awake Measures of Nasal Resistance and Upper Airway Resistance on CPAP during Sleep
    Masdeu, Maria J.
    Seelall, Vijay
    Patel, Amit V.
    Ayappa, Indu
    Rapoport, David M.
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2011, 7 (01): : 31 - 40
  • [28] Nasal resistance for determinant factor of nasal surgery in CPAP failure patients with obstructive sleep apnea syndrome
    Nakata, S
    Noda, A
    Yagi, H
    Yanagi, E
    Mimura, T
    Okada, T
    Misawa, H
    Nakashima, T
    RHINOLOGY, 2005, 43 (04) : 296 - 299
  • [29] Comparison of partially attended night time respiratory recordings and full polysomnography in patients with suspected sleep apnoea/hypopnoea syndrome
    Lloberes, P
    Montserrat, JM
    Ascaso, A
    Parra, O
    Granados, A
    Alonso, P
    Vilaseca, I
    RodriguezRoisin, R
    THORAX, 1996, 51 (10) : 1043 - 1047
  • [30] Effects of nasal obstruction on continuous positive airway pressure treatments in obstructive sleep apnea syndrome
    Nakata S.
    Noda A.
    Yagi H.
    Yanagi E.
    Suzuki K.
    Misawa H.
    Koike Y.
    Nakashima T.
    Sleep and Biological Rhythms, 2004, 2 (1) : 89 - 91