Quantitative photoacoustic measurement of blood oxygen saturation in vivo aided by an optical contrast agent

被引:0
|
作者
Rajian, Justin Rajesh [1 ]
Carson, Paul L. [1 ]
Fowlkes, J. Brian [1 ]
Wang, Xueding [1 ]
机构
[1] Univ Michigan, Dept Radiol, Sch Med, Ann Arbor, MI 48109 USA
来源
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2010 | 2010年 / 7564卷
关键词
Spectroscopy; photoacoustic imaging; blood oxygen saturation; contrast agent; HIGH-RESOLUTION; SCATTERING; SPECTROSCOPY; TOMOGRAPHY; HYPOXIA; SYSTEM;
D O I
10.1117/12.842004
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The characteristic absorption spectrum of hemoglobin depends upon the amount of oxygen the hemoglobin carries. This property of the hemoglobin enables one to image blood oxygen saturation distribution in biological tissues by using spectroscopic photoacoustic tomography. In photoacoustic imaging, the amplitude of photoacoustic signal induced by optical absorption is proportional to light energy deposition which is the product of the optical absorption coefficient and local light fluence at the imaging target. Since the attenuation of light in biological tissues are wavelength dependent, the spectrum of local light fluence at a target tissue beneath the sample surface is different from the spectrum of the incident light fluence above the surface. An unknown spectrum of the light fluence in the sample prevents us from obtaining quantitative functional images such as oxygen saturation and hemoglobin concentration in the sample by photoacoustic tomography. We developed a new technique of using an optical contrast agent with known optical absorption spectrum to obtain the accurate spectrum of light fluence at a subsurface target tissue such as a blood vessel beneath the sample surface. The technique has been validated by obtaining an accurate absorption spectrum of a micro-flow vessel buried in strong optical scattering media including diluted whole milk and chicken breast tissue. In this work, we further explored the capability of this technique through the experiments on tissue mimicking phantoms and living animals. By using this technique we were able to obtain accurate blood oxygen saturation in vessels buried at different depths in an optical scattering medium. Also, the oxygenation levels in main arteries in rat tails have been quantified more accurately in a noninvasive manner.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] System design for wearable blood oxygen saturation and pulse measurement device
    Fu, Yu
    Liu, Jian
    6TH INTERNATIONAL CONFERENCE ON APPLIED HUMAN FACTORS AND ERGONOMICS (AHFE 2015) AND THE AFFILIATED CONFERENCES, AHFE 2015, 2015, 3 : 1187 - 1194
  • [42] Method of blood oxygen saturation measurement based on RBF neural network
    Liu Qian
    Wang Xiaofei
    PROCEEDINGS OF THE FIFTH INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION & INSTRUMENTATION, VOLS 1 AND 2, 2014, : 542 - 547
  • [43] Three-wavelength technique for the measurement of oxygen saturation in arterial blood and in venous blood
    Nitzan, Meir
    Engelberg, Shlomo
    JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (02)
  • [44] Switchable Acoustic and Optical Resolution Photoacoustic Microscopy for In Vivo Small-animal Blood Vasculature Imaging
    Moothanchery, Mohesh
    Sharma, Arunima
    Pramanik, Manojit
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (124):
  • [45] Dual-wavelength photothermal optical coherence tomography for imaging microvasculature blood oxygen saturation
    Yin, Biwei
    Kuranov, Roman V.
    McElroy, Austin B.
    Kazmi, Shams
    Dunn, Andrew K.
    Duong, Timothy Q.
    Milner, Thomas E.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (05)
  • [46] Assessment of blood oxygen saturation using spectroscopic photoacoustic imaging as a biomarker for disease progression in a small-animal leukemia model
    Wood, Cayla
    Harutyunyan, Karine
    De La Cerda, Jorge
    Kaffes, Caterina
    Millward, Niki Zacharias
    Shanmugavelandy, Sriram
    Konopleva, Marina
    Bouchard, Richard
    MEDICAL IMAGING 2018: ULTRASONIC IMAGING AND TOMOGRAPHY, 2018, 10580
  • [47] Determination of in vivo Blood Oxygen Saturation and Blood Volume Fraction Using Diffuse Reflectance Spectroscopy
    Chen, P.
    Lin, W.
    26TH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE: SBEC 2010, 2010, 32 : 336 - 339
  • [48] In vitro photoacoustic measurement of hemoglobin oxygen saturation using a single pulsed broadband supercontinuum laser source
    Lee, Changho
    Jeon, Mansik
    Jeon, Min Yong
    Kim, Jeehyun
    Kim, Chulhong
    APPLIED OPTICS, 2014, 53 (18) : 3884 - 3889
  • [49] Using microbubbles as an MRI contrast agent for the measurement of cerebral blood volume
    Peng, Shin-Lei
    Wang, Fu-Nien
    Wang, Chung-Hsin
    Peng, Hsu-Hsia
    Lu, Chih-Tien
    Yeh, Chih-Kuang
    NMR IN BIOMEDICINE, 2013, 26 (11) : 1540 - 1546
  • [50] Assessing storage-induced red blood cell lesions using photoacoustic measurements of oxygen saturation and the frequency content of photoacoustic signals
    Hysi, Eno
    Strohm, Eric M.
    Bemdl, Elizabeth S. L.
    Kolios, Michael C.
    Acker, Jason P.
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1662 - 1665