Monte Carlo calculation of x-rays deposited energy in CdZnTe detector

被引:2
|
作者
Stankovic, Sj [1 ]
Petrovic, M. [1 ]
Kovacevic, M. [1 ]
Vasic, A. [1 ]
Osmokrovic, P. [1 ]
Loncar, B. [1 ]
机构
[1] Vinca Inst Nucl Sci, Radiat Protect Dept, POB 522, Belgrade 11001, Serbia
来源
RESEARCH TRENDS IN CONTEMPORARY MATERIALS SCIENCE | 2007年 / 555卷
关键词
absorbed dose; CdZnTe; deposited energy; Monte Carlo; X-rays;
D O I
10.4028/www.scientific.net/MSF.555.141
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
CdZnTe detectors have been employed in diagnostic X-ray spectroscopy. This paper presents the Monte Carlo calculation of X-ray deposited energy in a CdZnTe detector for different energies of photon beam. In incident photon direction, the distribution of absorbed dose as deposited energy in detector is determined, Based on the dependence of the detector response on the thickness and different Zn fractions, some conclusions about changes of the material characteristics could be drawn. Results of numerical simulation suggest that the CdZnTe detector could be suitable for X-ray low energy.
引用
收藏
页码:141 / +
页数:2
相关论文
共 50 条
  • [11] Detector of soft X-rays
    Dan'ko, S.A.
    Yartseva, O.N.
    Instruments and experimental techniques New York, 1988, : 482 - 484
  • [12] Monte Carlo Analysis of the Influence of Different Packaging on MOSFET Energy Response to X-rays and Gamma Radiation
    Stankovic, S. J.
    Ilic, R. D.
    Zivanovic, M.
    Jankovic, K. S.
    Loncar, B.
    ACTA PHYSICA POLONICA A, 2012, 122 (04) : 655 - 658
  • [13] Energy resolution of xenon proportional counters: Monte Carlo and experimental results for 5.9 keV x-rays
    Rachinhas, PJBM
    Dias, THVT
    Santos, FP
    Stauffer, AD
    Conde, CAN
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 90 - 92
  • [14] Characterization of an extrapolation chamber for low-energy X-rays: Experimental and Monte Carlo preliminary results
    Neves, Lucio P.
    Silva, Eric A. B.
    Perini, Ana P.
    Maidana, Nora L.
    Caldas, Linda V. E.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (07) : 1388 - 1391
  • [15] Monte Carlo simulation of the dose deposited into GAFCHROMIC® film by X-rays produced by the electron beam of PFMA-3
    Ceccolini, E.
    Rocchi, F.
    Mostacci, D.
    Sumini, M.
    Tartani, A.
    RADIATION MEASUREMENTS, 2012, 47 (10) : 1000 - 1004
  • [16] SEMICONDUCTOR DETECTOR PERFORMANCE FOR LOW-ENERGY X-RAYS
    JAKLEVIC, JM
    WALTON, JT
    MCMURRAY, RE
    MADDEN, NW
    GOULDING, FS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3): : 598 - 601
  • [17] Primary study of Monte Carlo simulation on CdZnTe nuclear detector
    Ren, SJ
    Sang, WB
    Jin, W
    Li, WW
    Zhang, Q
    Min, JH
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2004, 28 (02): : 191 - 195
  • [18] Characterization of a scintillating GEM detector with low energy x-rays
    Seravalli, E.
    de Boer, M. R.
    Geurink, F.
    Huizenga, J.
    Kreuger, R.
    Schippers, J. M.
    van Eijk, C. W. E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (21): : 6195 - 6209
  • [19] Modern CPAD Detector Technology for Higher Energy X-rays
    Ott, Holger
    Graf, Juergen
    Stuerzer, Tobias
    Ruf, Michael
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2016, 72 : S145 - S145
  • [20] Monte Carlo simulation of generations of continuous and characteristic X-rays by electron impact
    Fujii, Kentaro
    Nagatomi, Takaharu
    Kimura, Yoshihide
    Takai, Yoshizo
    Shimizu, Ryuichi
    Obori, Ken-Ichi
    Yurugi, Toshikazu
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2000, 39 (5 A): : 2863 - 2864