A follow-up study of welders' exposure to vibration in a heavy engineering production workshop

被引:8
作者
Burstrom, Lage [1 ]
Hagberg, Mats [2 ]
Liljeind, Ingrid [1 ]
Lundstrom, Ronnie [3 ]
Nilsson, Tohr [4 ]
Pettersson, Hans [1 ]
Wahlstrom, Jens [3 ]
机构
[1] Umea Univ, Dept Publ Hlth & Clin Med, SE-90187 Umea, Sweden
[2] Sahlgrens Univ Hosp, Dept Occupat & Environm Med, SE-40530 Gothenburg, Sweden
[3] Univ Hosp No Sweden, Dept Biomed Engn & Informat, SE-90185 Umea, Sweden
[4] Sundsvall Hosp, Dept Occupat & Environm Med, SE-85186 Sundsvall, Sweden
来源
JOURNAL OF LOW FREQUENCY NOISE VIBRATION AND ACTIVE CONTROL | 2010年 / 29卷 / 01期
关键词
Vibration; exposure; hand-arm; measurement; welders; HAND-ARM VIBRATION; WORKERS;
D O I
10.1260/0263-0923.29.1.33
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Manual work involving vibrating power tools is associated with symptoms that include vascular, neurological and musculoskeletal disorders. This study examines the vibration exposure of welders to determine the change between 1987 and 2008. Vibration measurements on handheld tools were used to evaluate the acceleration and the daily exposure time was determined by subjective rating. From these data, the 8-hour equivalent vibration exposure A(8), has been calculated. During the period, the A(8) decreased from 3.9 m/s(2) to 1.9 m/s(2). It was concluded that this decrease is the result of fewer vibrating tools and a decrease in daily exposure time. Although the daily vibration exposure has decreased over the study time, for some welders the daily vibration exposure A(8) is still above the action value set by the EU directive on vibration. This means more effort should be spent to decrease vibration exposure.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 14 条
[1]  
[Anonymous], 2002, OFFICIAL J EUROPEAN, VL177, P13
[2]  
BEHRENS V, 1984, J OCCUP ENVIRON MED, V26, P765
[3]   EPIDEMIOLOGICAL SURVEY OF SHIPYARD WORKERS EXPOSED TO HAND-ARM VIBRATION [J].
BOVENZI, M ;
PETRONIO, L ;
DIMARINO, F .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1980, 46 (03) :251-266
[4]   Fulfilling the hand-arm vibration requirements of the EU Machinery Directive [J].
Brereton, P ;
Hewitt, S .
JOURNAL OF LOW FREQUENCY NOISE VIBRATION AND ACTIVE CONTROL, 2000, 19 (03) :115-121
[5]   Comparison of different measures for hand-arm vibration exposure [J].
Burstrom, L ;
Lundstrom, R ;
Hagberg, M ;
Nilsson, T .
SAFETY SCIENCE, 1998, 28 (01) :3-14
[6]  
Burstrom L, 2009, P 2 INT C HUM VIBR E, P115
[7]  
EUROPEAN UNION, 1989, OFF J EUR COMM, VL183, p[296, 9]
[8]  
HAGBERG M, 2008, J OCCUPATIONAL MED T, V16, P3
[9]  
ISO, 2001, 534922001 ISO
[10]  
ISO I., 2001, 5349 1 MECH VIBRATIO