High sensitivity detectors based on cavity ring-down spectroscopy

被引:5
作者
Paldus, BA [1 ]
Fidric, BG [1 ]
Sanders, SS [1 ]
Tan, SM [1 ]
Pham, H [1 ]
Kachanov, AA [1 ]
Wahl, EH [1 ]
Crosson, ER [1 ]
机构
[1] Picarro Inc, Sunnyvale, CA 94085 USA
来源
OPTICALLY BASED BIOLOGICAL AND CHEMICAL SENSING FOR DEFENCE | 2004年 / 5617卷
关键词
cavity ring-down spectroscopy; diode laser; toxic gases; optical detection;
D O I
10.1117/12.578374
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Cavity ring-down spectroscopy (CRDS) can provide high sensitivity, high precision, and absolute calibration in a wide range of environments. We report on a compact cavity ring-down spectrometer that can measure atmospheric toxic industrial compounds such as hydrides and hydrazines. The ring-down spectrometer is fully contained in two 5 1/4" tall, 19" wide rack mount enclosures and utilizes a robust, near-infrared, fiber-coupled tunable diode laser. The instrument has a baseline sensitivity of 8 x 10(-11) cm(-1)/Hz(1/2). We will present the results of this study, which demonstrates the capability to detect toxic gases such as arsine, silane, and hydrazine (simulated using ammonia) in air at parts per billion (ppb) concentrations in less than I minute. We will also present results on CRDS instrument performance, including zero drift, precision, absolute accuracy, and linearity over a wide range of environmental operating conditions.
引用
收藏
页码:312 / 322
页数:11
相关论文
共 11 条
  • [1] [Anonymous], CALIFORNIA AIR RESOU
  • [2] BUSCH KW, 1999, CAVITY RINGDOWN SPEC
  • [3] Stable isotope ratios using cavity ring-down spectroscopy:: Determination of 13C/12C for carbon dioxide in human breath
    Crosson, ER
    Ricci, KN
    Richman, BA
    Chilese, FC
    Owano, TG
    Provencal, RA
    Todd, MW
    Glasser, J
    Kachanov, AA
    Paldus, BA
    Spence, TG
    Zare, RN
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (09) : 2003 - 2007
  • [4] Demtroder W., 1996, LASER SPECTROSCOPY
  • [5] The PNNL quantitative infrared database for gas-phase sensing: A spectral library for environmental, hazmat and public safety standoff detection
    Johnson, TJ
    Sams, RL
    Sharpe, SW
    [J]. CHEMICAL AND BIOLOGICAL POINT SENSORS FOR HOMELAND DEFENSE, 2004, 5269 : 159 - 167
  • [6] Absorption intensity of stretching overtone states of silane and germane
    Lin, H
    Wang, D
    Chen, XY
    Wang, XG
    Zhou, ZP
    Zhu, QS
    [J]. JOURNAL OF MOLECULAR SPECTROSCOPY, 1998, 192 (02) : 249 - 256
  • [7] CAVITY RING-DOWN OPTICAL SPECTROMETER FOR ABSORPTION-MEASUREMENTS USING PULSED LASER SOURCES
    OKEEFE, A
    DEACON, DAG
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (12) : 2544 - 2551
  • [8] A laser-locked cavity ring-down spectrometer employing an analog detection scheme
    Spence, TG
    Harb, CC
    Paldus, BA
    Zare, RN
    Willke, B
    Byer, RL
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02) : 347 - 353
  • [9] *US EPA, 1984, HLTH ENV EFFECTS PRO
  • [10] van Zee R. D., 2002, EXPT METHODS PHYS SC, V40