Evaluation of obstetric gestures: An approach based on the curvature of 3-D positions

被引:4
作者
Moreau, R. [1 ]
Ochoa, V. [2 ]
Pham, M. T. [1 ]
Boulanger, P. [2 ]
Redarce, T. [1 ]
Dupuis, O. [3 ]
机构
[1] Inst Natl Sci Appl, Ampere Lab, F-69621 Villeurbanne, France
[2] Univ Alberta, AMMI Lab, Dept Comp Sci, Edmonton, AB T6G2E8, Canada
[3] CHU Lyon Sud, F-69495 Pierre Benite, France
来源
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16 | 2007年
关键词
D O I
10.1109/IEMBS.2007.4353118
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a method to evaluate a gesture carried out by a resident obstetrician doctors by comparing it to a gesture carried out by an expert obstetrician doctors. The studied gesture is the forceps blade placement. Residents were recorded on a childbirth simulator while placing forceps blades. Their paths were compared in order to evaluate how similar they are to a reference path defined by an expert. The comparison method is developed with respect to expert requests: time independence and in considering the whole set of data and not only particular points. In order to respect these requests, the developed method lies on the correlation coefficient between the path curvatures. Residents have been trained on a simulator and their gestures were evaluated by comparing their path curvatures to reference path curvatures. Quantitative results confirm the qualitative analysis, residents become more similar to the reference while training on simulator.
引用
收藏
页码:3634 / +
页数:2
相关论文
共 11 条
[1]  
Al Bassit L, 2003, PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS 2003, VOL 1-3, P906
[2]  
[Anonymous], 1896, Phil Trans R Soc A, DOI 10.1098/rsta.1896.0007
[3]  
CAO C, 1996, ASME IMECE S HAPT IN, P583
[4]  
Cunningham FG., 2005, Williams Obstetrics. 22th
[5]   A new obstetric forceps for the training of junior doctors: A comparison of the spatial dispersion of forceps blade trajectories between junior and senior obstetricians [J].
Dupuis, Olivier ;
Moreau, Richard ;
Silveira, Ruimark ;
Pham, Minh Tu ;
Zentner, Adrien ;
Cucherat, Michel ;
Rudigoz, Rene-Charles ;
Redarce, Tanneguy .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2006, 194 (06) :1524-1531
[6]  
MOREAU R, 2006, IEEE INT C ENG MED B, P4416
[7]   Paths analysis for a safe forceps blades placement on the BirthSIM simulator [J].
Moreau, Richard ;
Olaby, Osama ;
Dupuis, Olivier ;
Pham, Minh Tu ;
Redarce, Tanneguy .
2006 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), VOLS 1-10, 2006, :739-+
[8]   Design of a new instrumented forceps: Application to safe obstetrical forceps blade placement [J].
Moreau, Richard ;
Pham, Minh Tu ;
Silveira, Ruirnark ;
Redarce, Tanneguy ;
Brun, Xavier ;
Dupuis, Olivier .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (07) :1280-1290
[9]  
PIERROT F, 2000, IEEE ICRA SAN FRANC, P1615
[10]  
Rosen Jacob, 2002, Comput Aided Surg, V7, P49, DOI 10.1002/igs.10026