Effect of Mydriasis-Caused Intraocular Pressure Changes on Corneal Biomechanical Metrics

被引:7
作者
Ye, Yufeng [1 ]
Li, Yi [2 ]
Zhu, Zehui [1 ]
Abu Said, Anas Ziad Masoud [1 ]
Nguelemo Mayopa, Kevin [1 ]
Akiti, Stephen [1 ]
Huang, Chengyi [1 ]
Lopes, Bernardo T. [3 ]
Eliasy, Ashkan [3 ]
Miao, Yuanyuan [1 ]
Wang, Junjie [1 ,4 ]
Zheng, Xiaobo [1 ,4 ]
Chen, Shihao [1 ,4 ]
Bao, Fangjun [1 ,4 ]
Elsheikh, Ahmed [3 ,5 ,6 ]
机构
[1] Wenzhou Med Univ, Eye Hosp, Wenzhou, Peoples R China
[2] Fudan Univ, North Huashan Hosp, Shanghai, Peoples R China
[3] Univ Liverpool, Sch Engn, Liverpool, Merseyside, England
[4] Wenzhou Med Univ, Inst Ocular Biomech, Wenzhou, Peoples R China
[5] Moorfields Eye Hosp NHS Fdn Trust, Natl Inst Hlth Res NIHR, Biomed Res Ctr Ophthalmol, UCL Inst Ophthalmol, London, England
[6] Beihang Univ, Beijing Adv Innovat Ctr Biomed Engn, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
biomechanical metrics; intraocular pressure; mydriasis; stiffness parameter at first applanation; stress-strain index; EYE-DROPS; PARAMETERS; PACHYMETRY; THICKNESS; HEALTHY;
D O I
10.3389/fbioe.2021.751628
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose: To evaluate the dependence of biomechanical metrics on intraocular pressure (IOP).Methods: 233 refractive surgery patients were included in this study-all were examined 3 times with the Corvis ST before and after dilation, and the differences ( increment ) in the main device parameters were assessed. The data collected included the biomechanically corrected IOP (bIOP), the central corneal thickness (CCT), and six dynamic corneal response (DCR) parameters, namely DA, DARatio2mm, IIR, SP-A1, CBI, and SSI. Participants were divided into three groups according to the changes in patients' bIOP after mydriasis.Results: Intra-operator repeatability was generally high in most of the DCR parameters obtained before and after dilation. The mean changes in bIOP and CCT after dilation were -0.12 +/- 1.36 mmHg and 1.95 +/- 5.23 mu m, respectively. Only increment DARatio2mm, increment IIR, and increment CBI exhibited a statistically significant correlation with increment CCT (p < 0.05). The changes in all DCR parameters, especially increment DA and increment SP-A1 were also correlated with increment bIOP (p < 0.01)-a 1-mmHg change in bIOP was associated, on average, with 5.612 and -0.037 units of change in SP-A1 and DA, respectively. In contrast, the weakest correlation with increment bIOP was exhibited by increment SSI.Conclusion: Most corneal DCR parameters, provided by the Corvis ST, were correlated with IOP, and more weakly with CCT. Changes experienced in CCT and IOP should therefore be considered in studies on corneal biomechanics and how it is affected by disease progression and surgical or medical procedures.
引用
收藏
页数:8
相关论文
共 29 条
[21]   Corneal Biomechanical Properties in Varying Severities of Myopia [J].
Sedaghat, Mohammad-Reza ;
Momeni-Moghaddam, Hamed ;
Azimi, Abbas ;
Fakhimi, Zohreh ;
Ziaei, Mohammed ;
Danesh, Zeynad ;
Roberts, Cynthia J. ;
Monfared, Naeemeh ;
Jamali, Alireza .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 8
[22]   Cardiovascular Adverse Effects of Phenylephrine Eyedrops A Systematic Review and Meta-analysis [J].
Stavert, Bethany ;
McGuinness, Myra B. ;
Harper, C. Alex ;
Guymer, Robyn H. ;
Finger, Robert P. .
JAMA OPHTHALMOLOGY, 2015, 133 (06) :647-652
[23]   Is Routine Pupil Dilation Safe among Asian Patients with Diabetes? [J].
Tan, Gavin S. ;
Wong, Ching-Yee ;
Wong, Tien Yin ;
Govindasamy, Chitra V. ;
Wong, Edmund Y. ;
Yeo, Ian Y. ;
Aung, Tin .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (09) :4110-4113
[24]  
VALLE O, 1974, ACTA OPHTHALMOL, P52
[25]   Influence of Pachymetry and Intraocular Pressure on Dynamic Corneal Response Parameters in Healthy Patients [J].
Vinciguerra, Riccardo ;
Elsheikh, Ahmed ;
Roberts, Cynthia J. ;
Ambrosio, Renato, Jr. ;
Kang, David Sung Yong ;
Lopes, Bernardo T. ;
Morenghi, Emanuela ;
Azzolini, Claudio ;
Vinciguerra, Paolo .
JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (08) :550-561
[26]   Repeatability and comparison of new Corvis ST parameters in normal and keratoconus eyes [J].
Yang, Kaili ;
Xu, Liyan ;
Fan, Qi ;
Zhao, Dongqing ;
Ren, Shengwei .
SCIENTIFIC REPORTS, 2019, 9 (1)
[27]   Effects of Mydrin eye-drops on central corneal thickness values in adult patients with myopia [J].
Zeng, Yuan ;
Gao, Jian-Hua .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2017, 100 (02) :151-154
[28]   Biomechanical Effects of Two Forms of PGF2α on Ex-vivo Rabbit Cornea [J].
Zhu, Rong ;
Zheng, XiaoBo ;
Guo, LiLi ;
Zhao, YiPing ;
Wang, Yuan ;
Wu, Jie ;
Yu, Ayong ;
Wang, JunJie ;
Bao, FangJun ;
Elsheikh, Ahmed .
CURRENT EYE RESEARCH, 2021, 46 (04) :452-460
[29]   Corneal Hysteresis as a Biomarker of Glaucoma: Current Insights [J].
Zimprich, Larae ;
Diedrich, Jacob ;
Bleeker, Adam ;
Schweitzer, Justin A. .
CLINICAL OPHTHALMOLOGY, 2020, 14 :2255-2264