Application of maximum-likelihood estimation in optical coherence tomography for nanometer-class thickness estimation

被引:0
|
作者
Huang, Jinxin [1 ]
Yuan, Qun [2 ,3 ]
Tankam, Patrice [2 ]
Clarkson, Eric [4 ]
Kupinski, Matthew [5 ]
Hindman, Holly B. [6 ]
Aquavella, James V. [6 ]
Rolland, Jannick P. [2 ]
机构
[1] Univ Rochester, Dept Phys & Astron, Rochester, NY 14627 USA
[2] Univ Rochester, Inst Opt, Rochester, NY 14627 USA
[3] Nanjing Univ Sci & Technol, Sch Elect & Opt Engn, Nanjing 210094, Jiangsu, Peoples R China
[4] Univ Arizona, Dept Radiol, Tucson, AZ 85720 USA
[5] Univ Arizona, Coll Opt Sci, Tucson, AZ 85720 USA
[6] Univ Rochester, Flaum Eye Inst, Rochester, NY 14642 USA
来源
Design and Quality for Biomedical Technologies VIII | 2015年 / 9315卷
关键词
Task-based assessment; optical instrumentation; coherence and statistical optics; optical coherence tomography; TEAR FILM THICKNESS; EYE WORKSHOP 2007; REFRACTIVE-INDEX; SUBCOMMITTEE; PRECORNEAL; DYNAMICS; DISEASE; PHANTOM;
D O I
10.1117/12.2083160
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In biophotonics imaging, one important and quantitative task is layer-thickness estimation. In this study, we investigate the approach of combining optical coherence tomography and a maximum-likelihood (ML) estimator for layer thickness estimation in the context of tear film imaging. The motivation of this study is to extend our understanding of tear film dynamics, which is the prerequisite to advance the management of Dry Eye Disease, through the simultaneous estimation of the thickness of the tear film lipid and aqueous layers. The estimator takes into account the different statistical processes associated with the imaging chain. We theoretically investigated the impact of key system parameters, such as the axial point spread functions (PSF) and various sources of noise on measurement uncertainty. Simulations show that an OCT system with a 1 mu m axial PSF (FWHM) allows unbiased estimates down to nanometers with nanometer precision. In implementation, we built a customized Fourier domain OCT system that operates in the 600 to 1000 nm spectral window and achieves 0.93 micron axial PSF in corneal epithelium. We then validated the theoretical framework with physical phantoms made of custom optical coatings, with layer thicknesses from tens of nanometers to microns. Results demonstrate unbiased nanometer-class thickness estimates in three different physical phantoms.
引用
收藏
页数:6
相关论文
共 50 条
  • [11] Flow rate estimation by optical coherence tomography using contrast dilution approach
    Stohanzlova, Petra
    Kolar, Radim
    OPTICAL COHERENCE IMAGING TECHNIQUES AND IMAGING IN SCATTERING MEDIA, 2015, 9541
  • [12] Estimation of the Degree of Endolymphatic Hydrops Using Optical Coherence Tomography
    Karvonen, Tuukka
    Uranishi, Yuki
    Sakamoto, Tatsunori
    Tona, Yosuke
    Okamoto, Kazuya
    Tamura, Hiroshi
    Kuroda, Tomohiro
    ADVANCED BIOMEDICAL ENGINEERING, 2016, 5 : 19 - 25
  • [13] Phase estimation for global defocus correction in optical coherence tomography
    Jensen, Mikkel
    Israelsen, Niels M.
    Podoleanu, Adrian
    Bang, Ole
    2ND CANTERBURY CONFERENCE ON OCT WITH EMPHASIS ON BROADBAND OPTICAL SOURCES, 2018, 10591
  • [14] Spectral Analysis for Scatterer Estimation in Optical Coherence Tomography Images
    Bousi, Evgenia
    Kartakoullis, Andreas
    Pitris, Costas
    2009 9TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS IN BIOMEDICINE, 2009, : 502 - 505
  • [15] Numerical jitter estimation for swept source optical coherence tomography
    Zhu, Lida
    Miyazawa, Arata
    Mukherjee, Pradipta
    Abd El-Sadek, Ibrahim
    Oikawa, Kensuke
    Oida, Daisuke
    Yasuno, Yoshiaki
    BIOMEDICAL IMAGING AND SENSING CONFERENCE 2020, 2020, 11521
  • [16] Estimation of Refractive Index for Biological Tissue Using Micro-Optical Coherence Tomography
    Tang, Hongying
    Liu, Xinyu
    Chen, Si
    Yu, Xiaojun
    Luo, Yuemei
    Wu, Junying
    Wang, Xianghong
    Liu, Linbo
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (06) : 1803 - 1809
  • [17] Optical coherence tomography: Age estimation of Calliphora vicina pupae in vivo?
    Brown, Katherine
    Harvey, Michelle
    FORENSIC SCIENCE INTERNATIONAL, 2014, 242 : 157 - 161
  • [18] Improved method for amplitude estimation of time domain optical coherence tomography
    Jafari, R.
    Karimi-Ghartemani, M.
    Vitkin, I. A.
    2008 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-4, 2008, : 1905 - +
  • [19] Noninvasive Estimation of Pulsatile and Static Intracranial Pressure by Optical Coherence Tomography
    Jacobsen, Henrik Holvin
    Jorstad, Oystein Kalsnes
    Moe, Morten C.
    Petrovski, Goran
    Pripp, Are Hugo
    Sandell, Tiril
    Eide, Per Kristian
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (01):
  • [20] Application of optical coherence tomography and keratograph in the measurements of lower lid margin thickness
    Da-Hu Wang
    Jian-Cen Tang
    Xiao-Jun Hao
    Yin-Jian Zhang
    Xin-Quan Liu
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2023, 261 : 2327 - 2334