Cardiovascular magnetic resonance as a reliable alternative to cardiovascular computed tomography and transesophageal echocardiography for aortic annulus valve sizing

被引:8
作者
Faletti, Riccardo [1 ]
Gatti, Marco [1 ]
Salizzoni, Stefano [2 ]
Bergamasco, Laura [3 ]
Bonamini, Rodolfo [3 ]
Garabello, Domenica [4 ]
Marra, Walter Grosso [5 ]
La Torre, Michele [2 ]
Morello, Mara [5 ]
Veglia, Simona [4 ]
Fonio, Paolo [1 ]
Rinaldi, Mauro [2 ]
机构
[1] Univ Turin, Inst Radiol, Dept Surg Sci, Via Genova 3, I-10126 Turin, Italy
[2] Univ Turin, Div Cardiac Surg, Dept Surg Sci, Turin, Italy
[3] Univ Turin, Dept Surg Sci, Turin, Italy
[4] SC Radiodiagnost Osped, Dept Radiodiagnost, Turin, Italy
[5] Univ Turin, Div Cardiol, Dept Med Sci, Turin, Italy
关键词
Aortic stenosis; Transcatheter aortic valve implantation; Transesophageal echocardiography; Cardiovascular computed tomography; Cardiovascular magnetic resonance; DIAMETER MEASUREMENT; TRANSCATHETER; IMPLANTATION; STENOSIS; OUTCOMES; ROOT; REPLACEMENT; ANGIOGRAPHY; ACCURACY; CT;
D O I
10.1007/s10554-016-0899-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess the accuracy and reproducibly of cardiovascular magnetic resonance (CMR) in the measurement of the aortic annulus and in process of valve sizing as compared to intra-operative sizing, cardiovascular computed tomography (CCT) and transesophageal echocardiography (TEE). Retrospective study on 42 patients who underwent aortic valve replacement from September 2010 to September 2015, with available records of pre surgery annulus assessment by CMR, CCT and TEE and of peri-operative assessment. In CCT and CMR, the annular plane was considered a virtual ring formed by the lowest hinge points of the valvular attachments to the aorta. In TEE the annulus was measured at the base of leaflet insertion in the mid-esophageal long-axis view using the X-plane technique. Two double-blinded operators performed the assessments for each imaging technique. Intra-operative evaluation was performed using Hegar dilators. Continuous variables were studied with within-subject ANOVA, Bland-Altman (BA) plots, Wilcoxon's and Friedman's tests; trends were explored with scatter plots. Categorical variables were studied with Fisher's exact test. The intra- and inter-operator reliability was satisfying. There were no significant differences between the annulus dimensions measured by CMR and either one of the three references. Valve sizing for CoreValve by CMR had the same good agreement with CCT and TEE, with a 78 % match rate; for SAPIEN XT the agreement was slightly better (82 %) for CCT than for TEE (66 %). MR performs well when compared to the surgical reference of intra-operative sizing and stands up to the level of the most used imaging references (CCT and TEE).
引用
收藏
页码:1255 / 1263
页数:9
相关论文
共 34 条
[1]  
[Anonymous], EUR HEART J CARDIOVA
[2]   Value of cardiac CT in comprehensive aortic valve and root evaluation before percutaneous aortic valve replacement [J].
Bazeed, Mohamed Fayez ;
Rezk, Ahmad Ibrahim ;
Moselhy, Mohamed Saleh .
ACTA RADIOLOGICA, 2013, 54 (05) :498-504
[3]   Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation [J].
Bernhardt, Peter ;
Rodewald, Christoph ;
Seeger, Julia ;
Gonska, Birgid ;
Buckert, Dominik ;
Radermacher, Michael ;
Hombach, Vinzenz ;
Rottbauer, Wolfgang ;
Woehrle, Jochen .
CLINICAL RESEARCH IN CARDIOLOGY, 2016, 105 (03) :273-278
[4]   30 days and midterm outcomes of patients undergoing percutaneous replacement of aortic valve according to their renal function: A multicenter study [J].
D'Ascenzo, Fabrizio ;
Moretti, Claudio ;
Salizzoni, Stefano ;
Bollati, Mario ;
D'Amico, Maurizio ;
Ballocca, Flavia ;
Giordana, Francesca ;
Barbanti, Marco ;
Ussia, Gian Paolo ;
Brambilla, Nedy ;
Bedogni, Francesco ;
Zoccai, Giuseppe Biondi ;
Tamburino, Corrado ;
Gaita, Fiorenzo ;
Sheiban, Imad .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (04) :1514-1518
[5]   Medium Term Outcomes of Transapical Aortic Valve Implantation: Results From the Italian Registry of Trans-Apical Aortic Valve Implantation [J].
D'Onofrio, Augusto ;
Salizzoni, Stefano ;
Agrifoglio, Marco ;
Cota, Linda ;
Luzi, Giampaolo ;
Tartara, Paolo M. ;
Cresce, Giovanni D. ;
Aiello, Marco ;
Savini, Carlo ;
Cassese, Mauro ;
Cerillo, Alfredo ;
Punta, Giuseppe ;
Cioni, Micaela ;
Gabbieri, Davide ;
Zanchettin, Chiara ;
Agostinelli, Andrea ;
Mazzaro, Enzo ;
Di Gregorio, Omar ;
Gatti, Giuseppe ;
Faggian, Giuseppe ;
Filippini, Claudia ;
Rinaldi, Mauro ;
Gerosa, Gino .
ANNALS OF THORACIC SURGERY, 2013, 96 (03) :830-836
[6]   Preoperative Assessment of Aortic Annulus Dimensions: Comparison of Noninvasive and Intraoperative Measurement [J].
Dashkevich, Alexey ;
Blanke, Philipp ;
Siepe, Matthias ;
Pache, Gregor ;
Langer, Mathias ;
Schlensak, Christian ;
Beyersdorf, Friedhelm .
ANNALS OF THORACIC SURGERY, 2011, 91 (03) :709-715
[7]   Diffuse myocardial fibrosis in severe aortic stenosis: an equilibrium contrast cardiovascular magnetic resonance study [J].
Flett, Andrew S. ;
Sado, Daniel M. ;
Quarta, Giovanni ;
Mirabel, Mariana ;
Pellerin, Denis ;
Herrey, Anna S. ;
Hausenloy, Derek J. ;
Ariti, Cono ;
Yap, John ;
Kolvekar, Shyam ;
Taylor, Andrew M. ;
Moon, James C. .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (10) :819-826
[8]   Moderate and Severe Preoperative Chronic Kidney Disease Worsen Clinical Outcomes After Transcatheter Aortic Valve Implantation Meta-Analysis of 4992 Patients [J].
Gargiulo, Giuseppe ;
Capodanno, Davide ;
Sannino, Anna ;
Perrino, Cinzia ;
Capranzano, Piera ;
Stabile, Eugenio ;
Trimarco, Bruno ;
Tamburino, Corrado ;
Esposito, Giovanni .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (02)
[9]   Multimodality Imaging in Transcatheter Aortic Valve Implantation and Post-Procedural Aortic Regurgitation Comparison Among Cardiovascular Magnetic Resonance, Cardiac Computed Tomography, and Echocardiography [J].
Jabbour, Andrew ;
Ismail, Tevfik F. ;
Moat, Neil ;
Gulati, Ankur ;
Roussin, Isabelle ;
Alpendurada, Francisco ;
Park, Bradley ;
Okoroafor, Francois ;
Asgar, Anita ;
Barker, Sarah ;
Davies, Simon ;
Prasad, Sanjay K. ;
Rubens, Michael ;
Mohiaddin, Raad H. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (21) :2165-2173
[10]   Transcatheter Aortic Valve Implantation in Aortic Stenosis: The Role of Echocardiography [J].
Jayasuriya, Cleonie ;
Moss, Robert Rex ;
Munt, Brad .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (01) :15-27