Assessing Body Fat of Children by Skinfold Thickness, Bioelectrical Impedance Analysis, and Dual-Energy X-Ray Absorptiometry: A Validation Study Among Malay Children Aged 7 to 11 Years

被引:17
|
作者
Noradilah, Mohd Jonit [1 ]
Ang, Yeow Nyin [1 ]
Kamaruddin, Nor Azmi [1 ]
Deurenberg, Paul
Ismail, Mohd Noor [2 ]
Poh, Bee Koon [1 ]
机构
[1] Univ Kebangsaan Malaysia, Kuala Lumpur, Malaysia
[2] Taylors Univ Subang Jaya, Selangor, Malaysia
关键词
body composition; bioelectrical impedance analysis; children; dual-energy X-ray absorptiometry; skinfold measurement; validation study; NUTRITION SURVEY; PUBERTAL CHANGES; YOUNG-ADULTS; FATNESS; YOUTH; MASS; ADOLESCENTS; EQUATIONS; DENSITY; SEANUTS;
D O I
10.1177/1010539516641505
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
This study aims to validate skinfold (SKF) and bioelectrical impedance analysis (BIA) against dual-energy X-ray absorptiometry (DXA) in determining body fat percentage (BF%) of Malay children aged 7 to 11 years. A total of 160 children had their BF% assessed using SKF and BIA, with DXA as the criterion method. Four SKF equations (SKFBray, SKFJohnston, SKFSlaughter, and SKFGoran) and 4 BIA equations (BIA(Manufacturer), BIA(Houtkooper), BIA(Rush), and BIA(Kushner)) were used to estimate BF%. Mean age, weight, and height were 9.4 +/- 1.1years, 30.5 +/- 9.9 kg, and 131.3 +/- 8.4 cm. All equations significantly underestimated BF% (P < .05). BIA equations had reasonable agreement with DXA and were independent of BF% with BIA(Manufacturer) being the best equation. Although BIA underestimates BF% as compared with DXA, BIA was more suitable to measure BF% in a population that is similar to this study sample than SKF, suggesting a need to develop new SKF equations that are population specific.
引用
收藏
页码:74S / 84S
页数:11
相关论文
共 50 条
  • [41] Body fat assessment in youth with overweight or obesity by an automated bioelectrical impedance analysis device, in comparison with the dual-energy x-ray absorptiometry: a cross sectional study
    Samouda, Hanen
    Langlet, Jeremie
    BMC ENDOCRINE DISORDERS, 2022, 22 (01)
  • [42] Validation of rapid 4-component body composition assessment with the use of dual-energy X-ray absorptiometry and bioelectrical impedance analysis
    Ng, Bennett K.
    Liu, Yong L.
    Wang, Wei
    Kelly, Thomas L.
    Wilson, Kevin E.
    Schoeller, Dale A.
    Heymsfield, Steven B.
    Shepherd, John A.
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2018, 108 (04) : 708 - 715
  • [43] Body composition assessment in adults with cystic fibrosis: comparison of dual-energy X-ray absorptiometry with skinfolds and bioelectrical impedance analysis
    King, S
    Wilson, J
    Kotsimbos, T
    Bailey, M
    Nyulasi, I
    NUTRITION, 2005, 21 (11-12) : 1087 - 1094
  • [44] ACCURACY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR BODY-COMPOSITION MEASUREMENTS IN CHILDREN
    ELLIS, KJ
    SHYPAILO, RJ
    PRATT, JA
    POND, WG
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1994, 60 (05) : 660 - 665
  • [45] Body Composition with Dual-Energy X-Ray Absorptiometry and Bioelectrical Impedance Analysis in Breast Cancer Survivors
    Lee, Kyuwan
    Sami, Nathalie
    Sweeney, Frank C.
    Dieli-Conwright, Christina M.
    NUTRITION IN CLINICAL PRACTICE, 2019, 34 (03) : 421 - 427
  • [46] Different calculations of fat-free mass by bioelectrical impedance analysis: Comparison with Dual-Energy X-Ray Absorptiometry
    Varlet-Marie, E.
    Grubka, E.
    Karafiat, M.
    Fedou, C.
    de Mauverger, E. Raynaud
    Brun, J. -F.
    SCIENCE & SPORTS, 2009, 24 (3-4) : 202 - 206
  • [47] Cross-calibration of multi-frequency bioelectrical impedance analysis with eight-point tactile electrodes and dual-energy X-ray absorptiometry for assessment of body composition in healthy children aged 6-18 years
    Lim, Jung S.
    Hwang, Jin S.
    Lee, Jun A.
    Kim, Dong H.
    Park, Kyung D.
    Jeong, Jin S.
    Cheon, Gi J.
    PEDIATRICS INTERNATIONAL, 2009, 51 (02) : 263 - 268
  • [48] Comparison of dual-energy X-ray absorptiometry, air displacement plethysmography and bioelectrical impedance analysis for the assessment of body composition in morbidly obese women
    Bedogni, G.
    Agosti, F.
    De Col, A.
    Marazzi, N.
    Tagliaferri, A.
    Sartorio, A.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2013, 67 (11) : 1129 - 1132
  • [49] Body fat measurement in elite sport climbers: Comparison of skinfold thickness equations with dual energy X-ray absorptiometry
    Espana Romero, Vanesa
    Ruiz, Jonatan R.
    Ortega, Francisco B.
    Artero, Enrique G.
    Vicente-Rodriguez, German
    Moreno, Luis A.
    Castillo, Manuel J.
    Gutierrez, Angel
    JOURNAL OF SPORTS SCIENCES, 2009, 27 (05) : 469 - 477
  • [50] Validity and reliability of bioelectrical impedance analysis to estimate body fat percentage against air displacement plethysmography and dual-energy X-ray absorptiometry
    von Hurst, Pamela R.
    Walsh, Daniel C. I.
    Conlon, Cathryn A.
    Ingram, Michelle
    Kruger, Rozanne
    Stonehouse, Welma
    NUTRITION & DIETETICS, 2016, 73 (02) : 197 - 204