Evaluation of Acoustic Radiation Force Impulse Imaging in Differentiating Benign and Malignant Cervical Lymphadenopathy

被引:1
作者
Rohan, Kamat [1 ]
Ramesh, Ananthakrishnan [1 ,4 ]
Nagarajan, K. [1 ]
Abdulbasith, K. [2 ]
Sureshkumar, Sathasivam [2 ]
Vijayakumar, Chellappa [2 ]
Balamourougan, K. [2 ]
Srinivas, B. [3 ]
机构
[1] Jawaharlal Inst Post Grad Med Educ & Res, Dept Radio Diag, Pondicherry, India
[2] Jawaharlal Inst Post Grad Med Educ & Res, Dept Gen Surg, Pondicherry, India
[3] Jawaharlal Inst Post Grad Med Educ & Res, Dept Pathol, Pondicherry, India
[4] Jawaharlal Inst Postgrad Med Educ & Res, Dept Radiodiag, Pondicherry 605006, India
关键词
biopsy. Acoustic radiation force impulse; acoustic radiation force impulse imaging; area ratio; cervical lymph nodes; shear wave velocity; Virtual Touch imaging; LYMPH-NODES; ULTRASOUND ELASTOGRAPHY; TISSUE QUANTIFICATION; DIAGNOSIS;
D O I
10.4103/JMU.JMU_10_21
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The aim of this study was to assess the diagnostic role of acoustic radiation force impulse imaging (ARFI) in differentiating benign and malignant cervical nodes. Methods: This was a diagnostic accuracy cross-sectional study. All patients who underwent ultrasound-guided fine-needle aspiration cytology (FNAC) of cervical nodes were included. Patients without FNAC/biopsy and patients in whom cervical nodes were cystic or completely necrotic were excluded. FNAC was used as reference investigation to predict the diagnostic accuracy. In all cases, FNAC was carried out after the B-mode, color Doppler and the ARFI imaging. In patients with multiple cervical lymph nodes, the most suspicious node based on grayscale findings was chosen for ARFI. ARFI included Virtual Touch imaging (VTI), area ratio (AR), and shear wave velocity (SWV) for each node, and the results were compared with FNAC/biopsy. Results: The final analysis included 166 patients. Dark VTI elastograms had sensitivity and specificity of 86.2% and 72.1%, respectively, in identifying malignant nodes. Sensitivity and specificity of AR were 71.3% and 82.3%, respectively, for a cutoff of 1.155. Median SWV of benign and malignant nodes was 1.9 [95% confidence interval (CI), 1.56-2.55] m/s and 6.7 (95% CI, 2.87-9.10) m/s, respectively. SWV > 2.68 m/s helped in identifying malignant nodes with 81% specificity, 81.6% sensitivity, and 81.3% accuracy. ARFI was found to be inaccurate in tuberculous and lymphomatous nodes. Conclusion: Malignant nodes had significantly darker elastograms, higher AR and SWV compared to benign nodes, and SWV was the most accurate parameter. ARFI accurately identifies malignant nodes, hence could potentially avoid unwarranted biopsy.
引用
收藏
页码:87 / 93
页数:7
相关论文
共 31 条
  • [1] Ultrasound of malignant cervical lymph nodes
    Ahuja, A. T.
    Ying, M.
    Ho, S. Y.
    Antonio, G.
    Lee, Y. P.
    King, A. D.
    Wong, K. T.
    [J]. CANCER IMAGING, 2008, 8 (01): : 48 - 56
  • [2] Sonographic evaluation of cervical lymph nodes
    Ahuja, AT
    Ying, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (05) : 1691 - 1699
  • [3] Accuracy of sonographic elastography in the differential diagnosis of enlarged cervical lymph nodes: Comparison with conventional B-mode sonography
    Alam, Farzana
    Naito, Kumiko
    Horiguchi, Jun
    Fukuda, Hiroshi
    Tachikake, Toshihiro
    Ito, Katsuhide
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (02) : 604 - 610
  • [4] Arda K, 2010, HUNG RADIOL ONLINE, V1, P10
  • [5] Acoustic Radiation Force Impulse Technology in the Differential Diagnosis of Solid Breast Masses with Different Sizes: Which Features Are Most Efficient?
    Bai, Min
    Zhang, Hui-Ping
    Xing, Jin-Fang
    Shi, Qiu-Sheng
    Gu, Ji-Ying
    Li, Fan
    Chen, Hui-Li
    Zhang, Xue-Mei
    Fang, Yun
    Du, Lian-Fang
    [J]. BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [6] Bhatia Kunwar S S, 2013, Cancer Imaging, V13, P253, DOI 10.1102/1470-7330.2013.0026
  • [7] Differentiating cervical metastatic lymphadenopathy and lymphoma by shear wave elastography
    Chae, Soo Young
    Jung, Hye Na
    Ryoo, Inseon
    Suh, Sangil
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [8] Differentiation of Metastatic Cervical Lymph Nodes With Ultrasound Elastography by Virtual Touch Tissue Imaging Preliminary Study
    Che, Dehong
    Zhou, Xianli
    Sun, Mei-Ling
    Wang, Xiao
    Jiang, Zhaopeng
    Wu, Changjun
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (01) : 37 - 42
  • [9] Noninvasive Evaluation of Benign and Malignant Superficial Lymph Nodes by Virtual Touch Tissue Quantification A Pilot Study
    Chen, Shaoqi
    Lin, Xiaoming
    Chen, Xiaoxia
    Zheng, Baoqun
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (03) : 571 - 575
  • [10] VIRTUAL TOUCH TISSUE IMAGING QUANTIFICATION SHEARWAVE ELASTOGRAPHY: PROSPECTIVE ASSESSMENT OF CERVICAL LYMPH NODES
    Cheng, Kai Lun
    Choi, Young Jun
    Shim, Woo Hyun
    Lee, Jeong Hyun
    Baek, Jung Hwan
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (02) : 378 - 386