Detection of C-Reactive Protein using network-deployable DNA aptamer based optical nanosensor

被引:9
|
作者
Ghosh, Shreya [1 ]
Metlushko, Anna [1 ]
Chaudhry, Shreya [1 ]
Dutta, Mitra [2 ]
Stroscio, Michael A. [3 ]
机构
[1] Univ Illinois, Dept Bioengn, Chicago, IL 60607 USA
[2] Univ Illinois, Dept Elect & Comp Engn, Dept Phys, Chicago, IL USA
[3] Univ Illinois, Dept Bioengn, Dept Elect & Comp Engn, Dept Phys, Chicago, IL USA
来源
2019 IEEE EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL & HEALTH INFORMATICS (BHI) | 2019年
关键词
aptamer; C-reactive protein; FRET; inflammation; quantum dot; optical sensor;
D O I
10.1109/bhi.2019.8834479
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Aptamer based sensors have been observed to have excellent recognition capacity towards various types of target molecules such as metal ions, proteins and other biomolecules. In this study, we report an optical 'turn off' nanosensor, which consists of a deoxyribonucleic acid aptamer attached to a quantum dot on the 5' terminus and gold nanoparticle on the 3' terminus. The sensor uses the principle of fluorescence resonance energy transfer to detect C - reactive protein. With an increase in the target concentration in the sensor, the photoluminescence intensity decreases resulting in an increase in quenching efficiency. The nanosensor has a limit of detection as low as 1.77 picomolar and is observed to be highly specific to C-reactive protein. It also successfully detects the target protein in clinical samples exhibiting around 10% quenching at 10 picomolar target concentration. Future work on this sensor will involve investigation of this sensor in an in vivo environment so that it can be deployed for inflammatory disease management.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] A photothermal biosensor for detection of C-reactive protein in human saliva
    Lee, Seung Hyeon
    Choi, Seoyeon
    Kwon, Kirok
    Bae, Nam-Ho
    Kwak, Bong Seop
    Cho, Won Chang
    Lee, Seok Jae
    Junga, Hyo-Il
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 246 : 471 - 476
  • [22] Reusable Immunosensor for Detection of C-reactive Protein in Human Serum
    Ribeiro, Sandro H. D.
    Alves, Livia M.
    Flauzino, Jose M. R.
    Moco, Anna C. R.
    Segatto, Monica S.
    Silva, Jonathan P.
    Borges, Lizandra F. A.
    Madurro, Joao M.
    Madurro, Ana G. B.
    ELECTROANALYSIS, 2020, 32 (10) : 2316 - 2322
  • [23] Detection and potential utility of C-reactive protein in saliva of neonates
    Iyengar, Anjali
    Paulus, Jessica K.
    Gerlanc, Daniel J.
    Maron, Jill L.
    FRONTIERS IN PEDIATRICS, 2014, 2
  • [24] Dual-Aptamer Assay for C-reactive Protein Detection by Using Field-effect Transistors on an Integrated Microfluidic System
    Kao, Wei-Chieh
    Chu, Chia-Ho
    Chang, Wen-Hsin
    Wang, Yu-Lin
    Lee, Gwo-Bin
    2016 IEEE 11TH ANNUAL INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2016,
  • [25] Immunosensor using surface plasmon resonance for C-reactive protein detection
    Casa, E
    Kurosawa, C
    Kurosawa, S
    Aizawa, H
    Park, JW
    Suzuki, H
    ELECTROCHEMISTRY, 2006, 74 (02) : 153 - 155
  • [26] Impedimetric, diamond-based immmunosensor for the detection of C-reactive protein
    Vermeeren, V.
    Grieten, L.
    Vanden Bon, N.
    Bijnens, N.
    Wenmackers, S.
    Janssens, S. D.
    Haenen, K.
    Wagner, P.
    Michiels, L.
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (01) : 130 - 138
  • [27] Label-free detection of C-reactive protein using a carbon nanofiber based biosensor
    Gupta, Rakesh K.
    Periyakaruppan, Adaikkappan
    Meyyappan, M.
    Koehne, Jessica E.
    BIOSENSORS & BIOELECTRONICS, 2014, 59 : 112 - 119
  • [28] Biosensor development for C-reactive protein detection: A review
    Balayan, Sapna
    Chauhan, Nidhi
    Rosario, Warren
    Jain, Utkarsh
    APPLIED SURFACE SCIENCE ADVANCES, 2022, 12
  • [29] Functionalized Gold Nanoparticles for the Detection of C-Reactive Protein
    Antonio, Maria
    Nogueira, Joao
    Vitorino, Rui
    Daniel-da-Silva, Ana L.
    NANOMATERIALS, 2018, 8 (04)
  • [30] A dual-aptamer sandwich assay by detection of C-reactive protein in synovial fluid on an integrated microfluidic system for diagnosis of periprosthetic joint infection
    Chen, To-Wen
    Wang, Chih-Hung
    Kuo, Feng-Chih
    Lee, Mel S.
    Lee, Gwo-Bin
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 424