Incidence and Predictors of Permanent Pacemaker Requirement after Transcatheter Aortic Valve Implantation with a Self-Expanding Bioprosthesis

被引:55
|
作者
Ferreira, Nuno Dias [1 ]
Caeiro, Daniel [1 ]
Adao, Luis [1 ]
Oliveira, Marco [1 ]
Goncalves, Helena [1 ]
Ribeiro, Jose [1 ]
Teixeira, Madalena [1 ]
Albuquerque, Anibal [1 ]
Primo, Joao [1 ]
Braga, Pedro [1 ]
Simoes, Lino [1 ]
Ribeiro, Vasco Gama [1 ]
机构
[1] Ctr Hosp Vila Nova de Gaia Espinho, Dept Cardiol, P-4434502 Vila Nova De Gaia, Portugal
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2010年 / 33卷 / 11期
关键词
aortic stenosis; transcatheter aortic valve implantation; permanent pacemaker; PROGNOSTIC-SIGNIFICANCE; RISK-FACTORS; FOLLOW-UP; REPLACEMENT; STENOSIS; PROSTHESIS; EXPERIENCE; ANATOMY; BLOCK;
D O I
10.1111/j.1540-8159.2010.02870.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Methods: From August 2007 to October 2009, 32 consecutive patients underwent TAVI with the Medtronic CoreValve (MCV) System (Medtronic Inc., Minneapolis, MN, USA). Three patients paced at baseline and two cases of procedure-related mortality were excluded. We analyzed the 12-lead electrocardiogram at baseline, immediately after procedure and at discharge. Requirements for PPM were documented and potential clinical, electrophysiological, echocardiographic, and procedural predictors of PPM requirement were studied. Results: After TAVI, eight patients (29.6%) required PPM implantation due to high-grade atrioventricular (AV) block. The prevalence of left bundle branch block increased from 13.8% to 57.7% directly after implantation (P = 0.001). Need for PPM was correlated to the depth of prosthesis implantation (r = 0.590; P = 0.001). At a cutoff point of 10.1 mm, the likelihood of pacemaker could be predicted with 87.5% sensitivity and 74% specificity and a receiver operator characteristic curve area of 0.86 +/- 0.07 (P = 0.003). Of the seven patients with preexisting right bundle branch block (RBBB), four (57.1%) required PPM implantation after TAVI. Conclusions: High-grade AV block requiring PPM implantation is a common complication following TAVI and could be predicted by a deeper implantation of the prosthesis. Patients with preexisting RBBB also seem to be at risk for the development of high-grade AV block and subsequent pacemaker implantation. (PACE 2010; 1364-1372).
引用
收藏
页码:1364 / 1372
页数:9
相关论文
共 50 条
  • [41] Minimizing Permanent Pacemaker Following Repositionable Self-Expanding Transcatheter Aortic Valve Replacement
    Jilaihawi, Hasan
    Zhao, Zhengang
    Du, Run
    Staniloae, Cezar
    Saric, Muhamed
    Neuburger, Peter J.
    Querijero, Michael
    Vainrib, Alan
    Hisamoto, Kazuhiro
    Ibrahim, Homam
    Collins, Tara
    Clark, Emily
    Pushkar, Illya
    Bamira, Daniel
    Benenstein, Ricardo
    Tariq, Afnan
    Williams, Mathew
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (18) : 1796 - 1807
  • [42] Resheathing of self-expanding bioprosthesis: Impact on procedural results, clinical outcome and prosthetic valve durability after transcatheter aortic valve implantation
    Kefer, Joelle
    Maes, Frederic
    Renkin, Jean
    Kautbally, Shakeel
    De Meester, Christophe
    Delacour, Marine
    Pouleur, Anne-Catherine
    IJC HEART & VASCULATURE, 2020, 26
  • [43] Incidence and predictors of permanent pacemaker implantation following treatment with the repositionable Lotus transcatheter aortic valve
    Zaman, Sarah
    McCormick, Liam
    Gooley, Robert
    Rashid, Hashrul
    Ramkumar, Satish
    Jackson, Damon
    Hui, Samuel
    Meredith, Ian T.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (01) : 147 - 154
  • [44] Balloon Post-Dilation Following Implantation of a Self-Expanding Transcatheter Aortic Valve Bioprosthesis
    Harrison, J. Kevin
    Hughes, G. Chad
    Reardon, Michael J.
    Stoler, Robert
    Grayburn, Paul
    Hebeler, Robert
    Liu, David
    Chang, Yanping
    Popma, Jeffrey J.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (02) : 168 - 175
  • [45] Impact of the use of cusp-overlap projection on the incidence of permanent pacemaker implantation post-transcatheter aortic valve implantation with self-expanding valves
    Moura, Ana Rita
    Rodrigues, Jose Alberto
    Braga, Pedro
    Melica, Bruno
    Santos, Lino
    Pires-Morais, Gustavo
    Sampaio, Francisco
    Fontes-Carvalho, Ricardo
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2023, 42 (09) : 759 - 769
  • [46] Transfermoral transcatheter aortic valve implantation using self-expanding Allegra bioprosthesis: One-year single-center outcomes
    Milan, Joanna
    Gozdek, Miroslaw
    Targonski, Radoslaw
    Kowalewski, Mariusz
    Stanska, Aleksandra
    Fijalkowski, Marcin
    Lango, Romuald
    Jaguszewski, Milosz
    Jagielak, Dariusz
    CARDIOLOGY JOURNAL, 2021, 28 (06) : 825 - 830
  • [47] Incidence and Predictors of Pacemaker Implantation in Patients Undergoing Transcatheter Aortic Valve Replacement
    Maan, Abhishek
    Refaat, Marwan M.
    Heist, Edwin Kevin
    Passeri, Jonathan
    Inglessis, Ignacio
    Ptaszek, Leon
    Vlahakes, Gus
    Ruskin, Jeremy N.
    Palacios, Igor
    Sundt, Thoralf
    Mansour, Moussa
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (07): : 878 - 886
  • [48] Risk for Permanent Pacemaker After Transcatheter Aortic Valve Implantation: A Comprehensive Analysis of the Literature
    Erkapic, Damir
    De Rosa, Salvatore
    Kelava, Augustin
    Lehmann, Ralf
    Fichtlscherer, Stephan
    Hohnloser, Stefan H.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (04) : 391 - 397
  • [49] Incidence, Predictors, and Prognostic Impact of New Permanent Pacemaker Implantation After TAVR With Self-Expanding Valves
    Pagnesi, Matteo
    Kim, Won-Keun
    Baggio, Sara
    Scotti, Andrea
    Barbanti, Marco
    De Marco, Federico
    Adamo, Marianna
    Eitan, Amnon
    Estevez-Loureiro, Rodrigo
    Conradi, Lenard
    Toggweiler, Stefan
    Mylotte, Darren
    Veulemans, Verena
    Sondergaard, Lars
    Wolf, Alexander
    Giannini, Francesco
    Maffeo, Diego
    Pilgrim, Thomas
    Montorfano, Matteo
    Zweiker, David
    Ferlini, Marco
    Kornowski, Ran
    Hildick-Smith, David
    Taramasso, Maurizio
    Abizaid, Alexandre
    Schofer, Joachim
    Sinning, Jan-Malte
    van Mieghem, Nicolas M.
    Woehrle, Jochen
    Khogali, Saib
    van der Heyden, Jan A. S.
    Wood, David A.
    Ielasi, Alfonso
    MacCarthy, Philip
    Brugaletta, Salvatore
    Hamm, Christian W.
    Costa, Giuliano
    Testa, Luca
    Massussi, Mauro
    Alarcon, Robert
    Schaefer, Ulrich
    Brunner, Stephanie
    Reimers, Bernhard
    Lunardi, Mattia
    Zeus, Tobias
    Vanhaverbeke, Maarten
    Naber, Christoph K.
    Di Ienno, Luca
    Buono, Andrea
    Windecker, Stephan
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (16) : 2004 - 2017
  • [50] Long-term outcomes following transcatheter aortic valve implantation with the Portico self-expanding valve
    Giordano, Arturo
    Mas-Peiro, Silvia
    Fichtlscherer, Stephan
    Schaefer, Andreas
    Beyer, Martin
    Maisano, Francesco
    Ascione, Guido
    Buzzatti, Nicola
    Teles, Rui
    Brito, Joao
    Albuquerque, Francisco
    Sondergaard, Lars
    Vanhaverbeke, Maarten
    Quagliana, Angelo
    Costa, Giuliano
    Barbanti, Marco
    Ferraro, Paolo
    Morello, Alberto
    Cimmino, Michele
    Albanese, Michele
    Pepe, Martino
    Bardi, Luca
    Giordano, Salvatore
    Cittadini, Antonio
    Corcione, Nicola
    Biondi-Zoccai, Giuseppe
    CLINICAL RESEARCH IN CARDIOLOGY, 2024, 113 (01) : 86 - 93