Incidence and Predictors of Permanent Pacemaker Requirement after Transcatheter Aortic Valve Implantation with a Self-Expanding Bioprosthesis

被引:56
作者
Ferreira, Nuno Dias [1 ]
Caeiro, Daniel [1 ]
Adao, Luis [1 ]
Oliveira, Marco [1 ]
Goncalves, Helena [1 ]
Ribeiro, Jose [1 ]
Teixeira, Madalena [1 ]
Albuquerque, Anibal [1 ]
Primo, Joao [1 ]
Braga, Pedro [1 ]
Simoes, Lino [1 ]
Ribeiro, Vasco Gama [1 ]
机构
[1] Ctr Hosp Vila Nova de Gaia Espinho, Dept Cardiol, P-4434502 Vila Nova De Gaia, Portugal
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2010年 / 33卷 / 11期
关键词
aortic stenosis; transcatheter aortic valve implantation; permanent pacemaker; PROGNOSTIC-SIGNIFICANCE; RISK-FACTORS; FOLLOW-UP; REPLACEMENT; STENOSIS; PROSTHESIS; EXPERIENCE; ANATOMY; BLOCK;
D O I
10.1111/j.1540-8159.2010.02870.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Methods: From August 2007 to October 2009, 32 consecutive patients underwent TAVI with the Medtronic CoreValve (MCV) System (Medtronic Inc., Minneapolis, MN, USA). Three patients paced at baseline and two cases of procedure-related mortality were excluded. We analyzed the 12-lead electrocardiogram at baseline, immediately after procedure and at discharge. Requirements for PPM were documented and potential clinical, electrophysiological, echocardiographic, and procedural predictors of PPM requirement were studied. Results: After TAVI, eight patients (29.6%) required PPM implantation due to high-grade atrioventricular (AV) block. The prevalence of left bundle branch block increased from 13.8% to 57.7% directly after implantation (P = 0.001). Need for PPM was correlated to the depth of prosthesis implantation (r = 0.590; P = 0.001). At a cutoff point of 10.1 mm, the likelihood of pacemaker could be predicted with 87.5% sensitivity and 74% specificity and a receiver operator characteristic curve area of 0.86 +/- 0.07 (P = 0.003). Of the seven patients with preexisting right bundle branch block (RBBB), four (57.1%) required PPM implantation after TAVI. Conclusions: High-grade AV block requiring PPM implantation is a common complication following TAVI and could be predicted by a deeper implantation of the prosthesis. Patients with preexisting RBBB also seem to be at risk for the development of high-grade AV block and subsequent pacemaker implantation. (PACE 2010; 1364-1372).
引用
收藏
页码:1364 / 1372
页数:9
相关论文
共 26 条
[1]   CALCIFIC AORTIC VALVULAR DISEASE ASSOCIATED WITH COMPLETE HEART BLOCK - CASE REPORTS OF SUCCESSFUL CORRECTION [J].
ABLAZA, SGG ;
BLANCO, G ;
MARANHAO, V ;
MORSE, DP ;
NICHOLS, HT .
DISEASES OF THE CHEST, 1968, 54 (05) :457-&
[2]   Novel therapeutic aspects of percutaneous aortic valve replacement with the 21F CoreValve Revalving™ system [J].
Berry, Colin ;
Asgar, Anita ;
Lamarche, Yoan ;
Marcheix, Bertrand ;
Couture, Pierre ;
Basmadjian, Arsene ;
Ducharme, Anique ;
Laborde, Jean-Claude ;
Cartier, Raymond ;
Bonan, Raoul .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 70 (04) :610-616
[3]   Early Conduction Disorders Following Percutaneous Aortic Valve Replacement [J].
Calvi, Valeria ;
Puzzangara, Euglena ;
Pruiti, Giusi Paola ;
Conti, Sergio ;
Di Grazia, Angelo ;
Ussia, Gian Paolo ;
Capodanno, Davide ;
Tamburino, Corrado .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 :S126-S130
[4]   Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description [J].
Cribier, A ;
Eltchaninoff, H ;
Bash, A ;
Borenstein, N ;
Tron, C ;
Bauer, F ;
Derumeaux, G ;
Anselme, F ;
Laborde, F ;
Leon, MB .
CIRCULATION, 2002, 106 (24) :3006-3008
[5]   Treatment of calcific aortic stenosis with the percutaneous heart valve - Mid-term follow-up from the initial feasibility studies: The French experience [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Nercolini, D ;
Tapiero, S ;
Litzler, PY ;
Bessou, JP ;
Babaliaros, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (06) :1214-1223
[6]   Permanent pacemaker implantation after isolated aortic valve replacement: Incidence, indications, and predictors [J].
Dawkins, Sam ;
Hobson, Alex R. ;
Kalra, Paul R. ;
Tang, Augustine T. M. ;
Monro, James L. ;
Dawkins, Keith D. .
ANNALS OF THORACIC SURGERY, 2008, 85 (01) :108-112
[7]   Contemporary surgical or percutaneous management of severe aortic stenosis in the elderly [J].
Descoutures, Fleur ;
Himbert, Dominique ;
Lepage, Laurent ;
Iung, Bernard ;
Detaint, Delphine ;
Tchetche, Didier ;
Brochet, Eric ;
Castier, Yves ;
Depoix, Jean-Pol ;
Nataf, Patrick ;
Vahanian, Alec .
EUROPEAN HEART JOURNAL, 2008, 29 (11) :1410-1417
[8]   Prognostic significance of newly acquired bundle branch block after aortic valve replacement [J].
El-Khally, Z ;
Thibault, B ;
Staniloae, C ;
Theroux, P ;
Dubuc, M ;
Roy, D ;
Guerra, P ;
Macle, L ;
Talajic, M .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (08) :1008-1011
[9]   Percutaneous aortic valve replacement for severe aortic stenosis in high-rick patients using the second- and current third-generation self-expanding CoreValve prosthesis - Device success and 30-day clinical outcome [J].
Grube, Eberhard ;
Schuler, Gerhard ;
Buellesfeld, Lutz ;
Gerckens, Ulrich ;
Linke, Axel ;
Wenaweser, Peter ;
Sauren, Barthel ;
Mohr, Friedrich-Wilhelm ;
Walther, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Felderhoff, Thomas ;
Cartier, Raymond ;
Bonan, Raoul .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) :69-76
[10]   Structure and anatomy of the aortic root [J].
Ho, Siew Yen .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (01) :I3-I10