Comparison of pulsed electrochemical detection modes coupled with microchip capillary electrophoresis

被引:24
|
作者
García, CD [1 ]
Henry, CS [1 ]
机构
[1] Colorado State Univ, Dept Chem, Ft Collins, CO 80523 USA
关键词
microchip capillary electrophoresis; pulsed electrochemical detection; pulsed amperometric detection; carbohydrate; SDS;
D O I
10.1002/elan.200403083
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There is a need to develop analytical methods that are capable of rapidly measuring small biological markers in the field of metabolomics. Among others, carbohydrates play an important role biologically yet are traditionally hard to detect since they have no chromophore or fluorophore. In the present report, the first application of integrated pulsed amperometric detection (iPAD) coupled with microchip electrophoresis to the analysis of glucose, mannose, sucrose, maltose. glucosamine, lactose, maltotriose and galactose is demonstrated. WAD is an electrochemical detection mode that can be used for direct detection of carbohydrates, amines and sulfur containing compounds. The effect of different solution parameters, including the buffer concentration, pH and the concentration of SDS on both separation and detection response was analyzed. In addition, a comparison study between PAD and WAD was performed using glucose, glucosamine, sucrose and maltose as model carbohydrates.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 50 条
  • [41] The use of discrete wavelets for signal denoising in microchip capillary electrophoresis
    Yan, Weiping
    Xu, Chengcai
    Li, Jianhua
    Huang, Junhuang
    WCICA 2006: SIXTH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-12, CONFERENCE PROCEEDINGS, 2006, : 5254 - +
  • [42] Analysis of alkyl polyglucosides in industrial products by capillary electrophoresis with pulsed amperometric detection
    Hübner, J
    Nguyen, A
    Turcu, F
    Melchior, D
    Kling, HW
    Gäb, S
    Schmitz, OJ
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (01) : 259 - 264
  • [43] An end-channel amperometric detector for microchip capillary electrophoresis
    Wu, YY
    Lin, JM
    Su, RG
    Qu, F
    Cai, ZW
    TALANTA, 2004, 64 (02) : 338 - 344
  • [44] Rapid Analysis for Staphylococcus aureus via Microchip Capillary Electrophoresis
    Chen, Jin
    Sun, Yu
    Peng, Xiaogai
    Ni, Yi
    Wang, Fengchao
    Dou, Xiaoming
    SENSORS, 2021, 21 (04) : 1 - 10
  • [45] Microchip capillary electrophoresis with a single-wall carbon nanotube/gold electrochemical detector for determination of aminophenols and neurotransmitters
    Pumera, M
    Llopis, X
    Merkoçi, A
    Alegret, S
    MICROCHIMICA ACTA, 2006, 152 (3-4) : 261 - 265
  • [46] Analysis of nucleic acids and proteins in capillary electrophoresis and microchip capillary electrophoresis using polymers as additives of the background electrolytes
    Hsieh, MM
    Chiu, TC
    Tseng, WL
    Chang, HT
    CURRENT ANALYTICAL CHEMISTRY, 2006, 2 (01) : 17 - 33
  • [47] Analysis of alkyl polyglucosides in industrial products by capillary electrophoresis with pulsed amperometric detection
    Jane Hübner
    Anh Nguyen
    Florin Turcu
    David Melchior
    Hans-Willi Kling
    Siegmar Gäb
    Oliver J. Schmitz
    Analytical and Bioanalytical Chemistry, 2006, 384 : 259 - 264
  • [48] Analytical applications of the electrochemiluminescence of tris(2,2′-bipyridyl)ruthenium(II) coupled to capillary/microchip electrophoresis: A review
    Su, Ming
    Wei, Wei
    Liu, Songqin
    ANALYTICA CHIMICA ACTA, 2011, 704 (1-2) : 16 - 32
  • [49] Low-density lipoprotein analysis in microchip capillary electrophoresis systems
    Ceriotti, L
    Shibata, T
    Folmer, B
    Weiller, BH
    Roberts, MA
    de Rooij, NF
    Verpoorte, E
    ELECTROPHORESIS, 2002, 23 (20) : 3615 - 3622
  • [50] Microchip capillary electrophoresis instrumentation for in situ analysis in the search for extraterrestrial life
    Mora, Maria F.
    Stockton, Amanda M.
    Willis, Peter A.
    ELECTROPHORESIS, 2012, 33 (17) : 2624 - 2638