Comparison of pulsed electrochemical detection modes coupled with microchip capillary electrophoresis

被引:24
|
作者
García, CD [1 ]
Henry, CS [1 ]
机构
[1] Colorado State Univ, Dept Chem, Ft Collins, CO 80523 USA
关键词
microchip capillary electrophoresis; pulsed electrochemical detection; pulsed amperometric detection; carbohydrate; SDS;
D O I
10.1002/elan.200403083
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There is a need to develop analytical methods that are capable of rapidly measuring small biological markers in the field of metabolomics. Among others, carbohydrates play an important role biologically yet are traditionally hard to detect since they have no chromophore or fluorophore. In the present report, the first application of integrated pulsed amperometric detection (iPAD) coupled with microchip electrophoresis to the analysis of glucose, mannose, sucrose, maltose. glucosamine, lactose, maltotriose and galactose is demonstrated. WAD is an electrochemical detection mode that can be used for direct detection of carbohydrates, amines and sulfur containing compounds. The effect of different solution parameters, including the buffer concentration, pH and the concentration of SDS on both separation and detection response was analyzed. In addition, a comparison study between PAD and WAD was performed using glucose, glucosamine, sucrose and maltose as model carbohydrates.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 50 条
  • [21] Microchip capillary electrophoresis using on-line chemiluminescence detection
    Hashimoto, M
    Tsukagoshi, K
    Nakajima, R
    Kondo, K
    Arai, A
    JOURNAL OF CHROMATOGRAPHY A, 2000, 867 (1-2) : 271 - 279
  • [22] Some aspects in capillary electrophoresis-electrochemical/electrochemiluminescence with microchip technique
    Yin, XB
    Yang, XR
    Wang, EK
    PROGRESS IN CHEMISTRY, 2005, 17 (02) : 181 - 185
  • [23] Rapid Detection of AGs using Microchip Capillary Electrophoresis Contactless Conductivity Detection
    Zhu, Gangzhi
    Bao, Chunjie
    Liu, Wenfang
    Yan, Xingxing
    Liu, Lili
    Xiao, Jian
    Chen, Chuanpin
    CURRENT PHARMACEUTICAL ANALYSIS, 2019, 15 (01) : 9 - 16
  • [24] Application of microchip electrophoresis with electrochemical detection to environmental aldehyde monitoring
    Dossi, Nicolo
    Susmel, Sabina
    Toniolo, Rosanna
    Pizzariello, Andrea
    Bontempelli, Gino
    ELECTROPHORESIS, 2009, 30 (19) : 3465 - 3471
  • [25] Capillary electrophoresis with pulsed amperometric detection of carbohydrates and glycopeptides
    Weber, PL
    Lunte, SM
    ELECTROPHORESIS, 1996, 17 (02) : 302 - 309
  • [26] Simultaneous determination of derivatized light aldehydes by microchip electrophoresis with electrochemical detection
    Dossi, Nicolo
    Susmel, Sabina
    Toniolo, Rosanna
    Pizzariello, Andrea
    Bontempelli, Gino
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1207 (1-2) : 169 - 174
  • [27] Estimation of pKa values using microchip capillary electrophoresis and indirect fluorescence detection
    Currie, CA
    Heineman, WR
    Halsall, HB
    Seliskar, CJ
    Limbach, PA
    Arias, F
    Wehmeyer, KR
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 824 (1-2): : 201 - 205
  • [28] Electrochemiluminescence detection system for microchip capillary electrophoresis and its application to pharmaceutical analysis
    Yang, Hui
    Li, Xin-chun
    Yang, Fan
    Feng, Jun
    Lin, Miao-yin
    Chen, Zuan-guang
    MICROCHIMICA ACTA, 2011, 175 (1-2) : 193 - 199
  • [29] Electrochemiluminescence detection system for microchip capillary electrophoresis and its application to pharmaceutical analysis
    Hui Yang
    Xin-chun Li
    Fan Yang
    Jun Feng
    Miao-yin Lin
    Zuan-guang Chen
    Microchimica Acta, 2011, 175 : 193 - 199
  • [30] Voltage control for microchip capillary electrophoresis analyses
    Bosma, Rick
    Devasagayam, Jasen
    Eswar, Rahul
    Albuquerque, Iasmin de Franca
    Collier, Christopher M.
    ELECTROPHORESIS, 2020, 41 (23) : 1961 - 1968