Quantitative Nondestructive Evaluation of Plastic Deformation in Carbon Steel Based on Electromagnetic Methods

被引:30
作者
Chen, Hong-En [1 ]
Xie, Shejuan [1 ]
Chen, Zhenmao [1 ]
Takagi, Toshiyuki [2 ]
Uchimoto, Tetsuya [2 ]
Yoshihara, Kensuke [3 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Strength & Vibrat Mech Struct, Xian 710049, Peoples R China
[2] Tohoku Univ, Inst Fluid Sci, Sendai, Miyagi 9808577, Japan
[3] Kansai Elect Power Co, Fukui 9191141, Japan
关键词
plastic deformation; carbon steel; Barkhausen noise; magnetic incremental permeability; magnetic flux leakage; BARKHAUSEN NOISE; STRESS;
D O I
10.2320/matertrans.M2014173
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Plastic deformation may occur in a mechanical structure during its manufacturing and service process, and may cause serious problem in the structural integrity. Therefore, a reliable pre-service or in service quantitative non-destructive evaluation (NDE) of plastic deformation is very important especially for a structure after suffering giant load such as a large earthquake. However, there is still no satisfactory method being established for the quantitative NDE of plastic deformation in key structures such as those of a nuclear power plant. For this purpose, three electromagnetic NDE methods, i.e., Magnetic Barkhausen Noise (MBN), Magnetic Incremental Permeability (MW) and Magnetic Flux Leakage (MFL) method are studied via experiments in this paper to investigate their feasibility for evaluation of plastic deformation in carbon steel SS400. A special testing system integrated these three electromagnetic NDE methods is established to measure the magnetic property of test-pieces with different plastic deformation, which was introduced by a tensile testing machine. It is found that the measurement signals of all these three methods have clear correlation with the plastic strains and show coincident tendency, which reveals the validity of these methods for the quantitative evaluation of plastic deformation. Among these methods, the MFL signals are of higher stability and repeatability but of relative low spatial resolution. The MBN method can give better resolution but of bigger standard deviation and is also not valid to evaluate a plastic strain of large scale. On the other hand, the MIP signals are more sensitive to the liftoff of sensor and to the remanent magnetization status, i.e. of more noise. Therefore, to measure the feature parameters of these three methods at the same time with an integrated testing system and to evaluate the plastic strain through signal fusion may give a better detectability and evaluation precision.
引用
收藏
页码:1806 / 1815
页数:10
相关论文
共 19 条
[1]   Robust solutions of inverse problems in electromagnetic non-destructive evaluation [J].
Altpeter, I ;
Becker, R ;
Dobmann, G ;
Kern, R ;
Theiner, W ;
Yashan, A .
INVERSE PROBLEMS, 2002, 18 (06) :1907-1921
[2]   Electromagnetism as a means for understanding materials mechanics phenomena in magnetic materials [J].
Boller, C. ;
Altpeter, I. ;
Dobmann, G. ;
Rabung, M. ;
Schreiber, J. ;
Szielasko, K. ;
Tschuncky, R. .
MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 2011, 42 (04) :269-278
[3]   Fast detection of the magnetic easy axis on steel sheet using the continuous rotational Barkhausen method [J].
Caldas-Morgan, M. ;
Padovese, L. R. .
NDT & E INTERNATIONAL, 2012, 45 (01) :148-155
[4]   Magnetic Barkhausen emission in lightly deformed AISI 1070 steel [J].
Capo Sanchez, J. ;
de Campos, M. F. ;
Padovese, L. R. .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2012, 324 (01) :11-14
[5]   Influence of uniaxial plastic deformation on magnetic Barkhausen noise in steel [J].
Dhar, A ;
Clapham, L ;
Atherton, DL .
NDT & E INTERNATIONAL, 2001, 34 (08) :507-514
[6]   Industrial Applications of 3MA-Micromagnetic Multiparameter Microstructure and Stress Analysis [J].
Dobmann, Gerd ;
Altpeter, Iris ;
Wolter, Bernd ;
Kern, Rolf .
ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (XI), 2008, 31 :18-+
[7]   Stress dependence of the spontaneous stray field signals of ferromagnetic steel [J].
Dong, Lihong ;
Xu, Binshi ;
Dong, Shiyun ;
Song, Li ;
Chen, Qunzhi ;
Wang, Dan .
NDT & E INTERNATIONAL, 2009, 42 (04) :323-327
[8]   On the role of residual internal stresses and dislocations on Barkhausen noise in plastically deformed steel [J].
Kleber, X ;
Vincent, A .
NDT & E INTERNATIONAL, 2004, 37 (06) :439-445
[9]   Application of a novel type Barkhausen noise sensor to continuous fatigue monitoring [J].
Lindgren, M ;
Lepistö, T .
NDT & E INTERNATIONAL, 2000, 33 (06) :423-428
[10]   A New Method for Evaluation of Mechanical Stress Using the Reciprocal Amplitude of Magnetic Barkhausen Noise [J].
Mierczak, L. ;
Jiles, D. C. ;
Fantoni, G. .
IEEE TRANSACTIONS ON MAGNETICS, 2011, 47 (02) :459-465