Development of Oxygen Consumption Analysis with an on-Chip Electrochemical Device and Simulation

被引:19
作者
Hiramoto, Kaoru [1 ]
Yasumi, Masahiro [1 ]
Ushio, Hiroshi [1 ]
Shunori, Atsushi [1 ]
Ino, Kosuke [2 ]
Shiku, Hitoshi [2 ]
Matsue, Tomokazu [3 ]
机构
[1] Panasonic Corp, Corp Engn Div, Automot & Ind Syst Co, 1006 Kadoma, Kadoma, Osaka 5710050, Japan
[2] Tohoku Univ, Grad Sch Engn, Aoba Ku, 6-6-11-406 Aramaki Aza Aoba, Sendai, Miyagi 9808579, Japan
[3] Tohoku Univ, Grad Sch Environm Studies, Aoba Ku, 6-6-11-605 Aramaki Aza Aoba, Sendai, Miyagi 9808579, Japan
基金
日本学术振兴会;
关键词
MOUSE EMBRYOID BODIES; RESPIRATORY ACTIVITY; IN-VITRO; ARRAYS; CELLS; MICROSCOPY; ELECTRODES;
D O I
10.1021/acs.analchem.7b02074
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The O-2 consumption rate of embryos has been attracting much attention as a key indicator of cell metabolisms and development. In this study, we propose an on-chip device that enables the accurate, easy, and noninvasive measurement of O-2 consumption rates of single embryos. Pt electrodes and micropits for embryo settlement were fabricated on Si chips via microfabrication techniques. The configuration of the device enables the detection of O-2 concentration profiles surrounding the embryos by settling embryos into the pits with a mouth pipet. Moreover, as the detection is based on an electrochemical method, the influence of O-2 consumption on the electrodes was also considered. By using a simulator (COMSOL Multiphysics), we estimated the O2 concentration profiles in the device with and without the effects of the electrodes. Based on the simulation results, we developed a normalization process to calculate the precise O-2 consumption rate of the sample. Finally, using both the measurement system and the algorithm for the analysis, the respiratory activities of mouse embryos were successfully measured.
引用
收藏
页码:10303 / 10310
页数:8
相关论文
共 18 条
[1]   Monitoring oxygen consumption of single mouse embryos using an integrated electrochemical microdevice [J].
Date, Yasumoto ;
Takano, Shinichiro ;
Shiku, Hitoshi ;
Ino, Kosuke ;
Ito-Sasaki, Takahiro ;
Yokoo, Masaki ;
Abe, Hiroyuki ;
Matsue, Tomokazu .
BIOSENSORS & BIOELECTRONICS, 2011, 30 (01) :100-106
[2]   Comparison of methods for measuring oxygen consumption in tumor cells in vitro [J].
Diepart, Caroline ;
Verrax, Julien ;
Calderon, Pedro Buc ;
Feron, Olivier ;
Jordan, Benedicte F. ;
Gallez, Bernard .
ANALYTICAL BIOCHEMISTRY, 2010, 396 (02) :250-256
[3]   CombiMatrix oligonucleotide arrays:: Genotyping and gene expression assays employing electrochemical detection [J].
Ghindilis, Andrey L. ;
Smith, Maria W. ;
Schwarzkopf, Kevin R. ;
Roth, Kristian M. ;
Peyvan, Kia ;
Munro, Sandra B. ;
Lodes, Michael J. ;
Stover, Axel G. ;
Bernards, Karen ;
Dill, Kilian ;
McShea, Andy .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (9-10) :1853-1860
[4]   A Novel Predictive Method for Assessing the Quality of Isolated Pancreatic Islets Using Scanning Electrochemical Microscopy [J].
Goto, M. ;
Abe, H. ;
Ito-Sasaki, T. ;
Goto, M. ;
Inagaki, A. ;
Ogawa, N. ;
Fujimori, K. ;
Kurokawa, Y. ;
Matsue, T. ;
Satomi, S. .
TRANSPLANTATION PROCEEDINGS, 2009, 41 (01) :311-313
[5]   Local Redox-Cycling-Based Electrochemical Chip Device with Deep Microwells for Evaluation of Embryoid Bodies [J].
Ino, Kosuke ;
Nishijo, Taku ;
Arai, Toshiharu ;
Kanno, Yusuke ;
Takahashi, Yasufumi ;
Shiku, Hitoshi ;
Matsue, Tomokazu .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2012, 51 (27) :6648-6652
[6]   Advanced LSI-based amperometric sensor array with light-shielding structure for effective removal of photocurrent and mode selectable function for individual operation of 400 electrodes [J].
Inoue, Kumi Y. ;
Matsudaira, Masahki ;
Nakano, Masanori ;
Ino, Kosuke ;
Sakamoto, Chika ;
Kanno, Yusuke ;
Kubo, Reyushi ;
Kunikata, Ryota ;
Kira, Atsushi ;
Suda, Atsushi ;
Tsurumi, Ryota ;
Shioya, Toshihito ;
Yoshida, Shinya ;
Muroyama, Masanori ;
Ishikawa, Tomohiro ;
Shiku, Hitoshi ;
Satoh, Shiro ;
Esashi, Masayoshi ;
Matsue, Tomokazu .
LAB ON A CHIP, 2015, 15 (03) :848-856
[7]   Parallel recording of neurotransmitters release from chromaffin cells using a 10 x 10 CMOS IC potentiostat array with on-chip working electrodes [J].
Kim, Brian N. ;
Herbst, Adam D. ;
Kim, Sung J. ;
Minch, Bradley A. ;
Lindau, Manfred .
BIOSENSORS & BIOELECTRONICS, 2013, 41 :736-744
[8]   Development of a new clinically applicable device for embryo evaluation which measures embryo oxygen consumption [J].
Kurosawa, Hiroki ;
Utsunomiya, Hiroki ;
Shiga, Naomi ;
Takahashi, Aiko ;
Ihara, Motomasa ;
Ishibashi, Masumi ;
Nishimoto, Mitsuo ;
Watanabe, Zen ;
Abe, Hiroyuki ;
Kumagai, Jin ;
Terada, Yukihiro ;
Igarashi, Hideki ;
Takahashi, Toshifumi ;
Fukui, Atsushi ;
Suganuma, Ryota ;
Tachibana, Masahito ;
Yaegashi, Nobuo .
HUMAN REPRODUCTION, 2016, 31 (10) :2321-2330
[9]  
Laborde C, 2015, NAT NANOTECHNOL, V10, P791, DOI [10.1038/nnano.2015.163, 10.1038/NNANO.2015.163]
[10]   A Pt layer/Pt disk electrode configuration to evaluate respiration and alkaline phosphatase activities of mouse embryoid bodies [J].
Obregon, Raquel ;
Horiguchi, Yoshiko ;
Arai, Toshiharu ;
Abe, Shihomi ;
Zhou, Yuanshu ;
RyosukeTakahashi ;
Hisada, Akiko ;
Ino, Kosuke ;
Shiku, Hitoshi ;
Matsue, Tomokazu .
TALANTA, 2012, 94 :30-35