Effects of panel zone yielding on seismic behavior of welded-flange-plate connections

被引:12
作者
Kosarieh, Amir Homayoon [1 ]
Danesh, Fakhreddin [1 ]
机构
[1] KN Toosi Univ Technol, Fac Civil Engn, Mirdamad Intersect, 1346 Vali Asr St,POB 15875-4416, Tehran 1996715433, Iran
关键词
Welded-flange-plate; Connection; Panel zone yielding; Plastic rotation; Seismic behavior; Energy dissipation; MOMENT CONNECTIONS; JOINT-PANEL; TESTS;
D O I
10.1007/s10518-016-9915-6
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
In this study, effects of panel zone yielding on the seismic performance of welded-flange-plate (WFP) connections are investigated. In this work, four full-scale beam-to-column connections were used to run the experiments under cyclic loading. The obtained results can potentially lead to a better understanding of the influence of the panel zone inelastic shear deformation on the cyclic behavior of WFP connections for external joints in steel moment resisting frames (SMRFs). The main parameter in the testing program was the panel zone strength having a wide variation to gain the different levels of panel zone yielding. Results showed that all specimens had a high connection rotation capacity to satisfy the requirements of special moment frame connections. However, specimens with different panel zone strengths could provide the different amount of energy dissipation. Severe beam buckling was followed by tearing along the k-line region of the beam in the plastic hinge location, as well as tearing of the beam at the nose of the bottom flange plates which were both observed as a predominant failure mode in the specimens with a stronger panel zone. However, specimens with weak panel zone could develop a significant plastic rotation without causing any major problem to the beam-to-column connection groove welds. Based on mentioned observations and considering the effect of panel zone yielding because of different panel zone strengths on the hysteresis behavior of specimens, failure modes, plastic rotation capacity, and energy dissipation, some modifications were proposed for design requirements of the panel zone strength.
引用
收藏
页码:2805 / 2825
页数:21
相关论文
共 33 条
[1]  
AIJ-1995d, 1995, AIJ1995D
[2]  
[Anonymous], 2011, AISC358S111
[3]  
[Anonymous], 2010, AISC36010
[4]  
[Anonymous], 2010, AISC34110
[5]  
Architectural Institute of Japan (AIJ), 2006, REC DES CONN STEEL S
[6]  
AWS, 2013, D112013 ANSIAWS
[7]  
Bertero V.V., 1973, FURTHER STUDIES SEIS
[8]   Shear strength of panel zone in beam-to-column connections [J].
Brandonisio, Giuseppe ;
De Luca, Antonio ;
Mele, Elena .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 71 :129-142
[9]   Shear instability of panel zone in beam-to-column connections [J].
Brandonisio, Giuseppe ;
De Luca, Antonio ;
Mele, Elena .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (05) :891-903
[10]  
El-Tawil S, 1998, STRENGTH DUCTILITY F