Evaluation of shear bond strength and adhesive remnant index of metal APC™ Flash-Free adhesive system: A comparative in vitro study with APC™ II and uncoated metal brackets

被引:6
|
作者
Akl, Roula [1 ]
Ghoubril, Joseph [1 ,4 ]
Le Gall, Michel [2 ]
Shatila, Rania [3 ]
Philip-Alliez, Camille [2 ]
机构
[1] St Joseph Univ, Sch Dent Med, Dept Orthodont, Beirut, Lebanon
[2] Hop La Timone, Serv Orthoped Dentofaciale, 264 Rue St Pierre, F-13005 Marseille, France
[3] Sci Univ Beirut, Fac Arts & Sci, Kamal A Shair Cent Res Sci Lab, POB 11-0236, Beirut 11072020, Lebanon
[4] St Joseph Univ Med Campus, 650 Damascus Rd, Beirut, Lebanon
关键词
Flash-Free; Precoated brackets; Shear bond strength; Adhesive remnant index; ENAMEL; TIME; VIVO;
D O I
10.1016/j.ortho.2022.100705
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective > The aim of this in vitro study was to compare the shear bond strength (SBS) and the adhesive remnant index (ARI) of the metal APC (TM) Flash-Free adhesive system, the APC (TM) pre-coated adhesive system and a conventional uncoated system. Materials and methods > One hundred eighty-six freshly extracted human premolars were randomly divided into 3 groups and bonded by a single operator. Group A/Control Group (60 teeth): the manual bonding group treated with Transbond (TM) XT Light Cure Adhesive Paste (3M (TM) Unitek). Group B (60 teeth): treated with APC (TM) II metal maxillary premolar precoated brackets. Group C (66 teeth): treated with metal maxillary premolar APC Flash-Free brackets. The teeth were then stored in distilled water at 37 C for 24 hours, and five hundred cycles of thermocycling were performed. The Shear Bond Strength (SBS) test was performed using an Instron Universal Testing Machine, and the adhesive remnant index (ARI) was determined using a dental optical microscope at x25 magnification. Results > The mean shear bond strength values showed differences between the three types of brackets (P = 0.016; Anova). It was significantly higher with APC (TM) II and lower with APC Flash-Free brackets; however, no significant differences were found between conventional and APC Flash-Free brackets (P-value = 0.574). The distribution of the dichotomized ARI score was significantly different between the three brackets (P-value = 0.049). The ARI score for APC Flash-Free brackets was higher with no significant difference between the conventional system and APC brackets (P-value = 0.361). Conclusions > The mean SBS values were not significantly different between APC Flash-Free metal brackets and uncoated metal brackets. The APC Flash-Free metal system's bond failure occurred at the bracket-adhesive interface, with the highest percentage of teeth having more than 50% of the residual composite on the enamel after debonding.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Comparison of Shear Bond Strength and Adhesive Remnant Index of Brackets Bonded with Two Types of Orthodontic Adhesives
    Mahmoud, Elsaafin
    Pacurar, Mariana
    Bechir, Edwin Sever
    Maris, Marius
    Olteanu, Cristian
    Dascalu, Ionela Teodora
    Moldovan, Marioara
    MATERIALE PLASTICE, 2017, 54 (01) : 141 - 144
  • [22] The effect of beer and milk tea on the shear bond strength of adhesive precoated brackets: An in vitro comparative study
    Vorachart, Weerada
    Sombuntham, Nonglak
    Parakonthun, Kulthida
    HELIYON, 2022, 8 (08)
  • [23] Evaluation of the shear bond strength and adhesive remnant index of color change, fluorescent, and conventional orthodontic adhesives: An in vitro study
    AlSamak, Saeed
    Alsaleem, Niam Riyadh
    Ahmed, Mahmood Kh.
    INTERNATIONAL ORTHODONTICS, 2023, 21 (01)
  • [24] Effect of torque customization with composite resin bases on the shear bond strength and adhesive remnant patterns of lingual brackets: An in vitro evaluation
    Kumar, Sekar Santhosh
    Ramteke, Shivangi
    Nivethitha, Bhaskar
    Madhan, Balasubramanian
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2024,
  • [25] A comparison of bond strength and adhesive remnant index of 3D-printed and metal orthodontic brackets attached using different adhesives
    Demirsoy, Kevser Kurt
    Buyuk, Suleyman Kutalmis
    Abay, Feridun
    Simsek, Huseyin
    Ozcelik, Esra
    AUSTRALASIAN ORTHODONTIC JOURNAL, 2023, 39 (02): : 32 - 39
  • [26] Effect of incorporating silica-hydroxyapatite-silver hybrid nanoparticles into the resin-modified glass ionomer on the adhesive remnant index score and shear bond strength of orthodontic metal brackets: An in vitro study
    Biglar, Nazila
    Raghimi, Elahe Chaychi
    Sadighian, Somayeh
    Karamitanha, Farzaneh
    Zajkani, Elham
    Nourian, Azin
    INTERNATIONAL ORTHODONTICS, 2023, 21 (03)
  • [27] Shear Bond Strength of Metal Brackets to Zirconia Following Different Surface Treatments using a Universal Adhesive
    Pouyanfar, Hoda
    Tabaii, Elaheh Seyed
    Bakhtiari, Mohammad
    Falah-Kooshki, Sepideh
    Teimourian, Hosna
    Imani, Mohammad Moslem
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (08) : ZC20 - ZC23
  • [28] Effect of different liquids on APC flash-free ceramic bracket's color stability, shear bond strength, and slot surface roughness
    Cevik, Seyda Canbaz
    Camci, Hasan
    Aslantas, Kubilay
    AUSTRALASIAN ORTHODONTIC JOURNAL, 2022, 38 (01): : 145 - 152
  • [29] Comparison of Shear Bond Strength and Adhesive Remnant Score of Orthodontic Brackets Bonded with Three Different Orthodontic Adhesives: An In-vitro Study
    Ramsundar, Kavitha
    Jain, Ravindra Kumar
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2023, 17 (11) : ZC21 - ZC24
  • [30] The Shear Bond Strengths of Metal and Ceramic Brackets: An in-Vitro Comparative Study
    Reddy, Y. G.
    Sharma, Rohit
    Singh, Ammandeep
    Agrawal, Vishal
    Agrawal, Vijay
    Chaturvedi, Saurab
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2013, 7 (07) : 1495 - 1497