Evaluation of shear bond strength and adhesive remnant index of metal APC™ Flash-Free adhesive system: A comparative in vitro study with APC™ II and uncoated metal brackets

被引:6
|
作者
Akl, Roula [1 ]
Ghoubril, Joseph [1 ,4 ]
Le Gall, Michel [2 ]
Shatila, Rania [3 ]
Philip-Alliez, Camille [2 ]
机构
[1] St Joseph Univ, Sch Dent Med, Dept Orthodont, Beirut, Lebanon
[2] Hop La Timone, Serv Orthoped Dentofaciale, 264 Rue St Pierre, F-13005 Marseille, France
[3] Sci Univ Beirut, Fac Arts & Sci, Kamal A Shair Cent Res Sci Lab, POB 11-0236, Beirut 11072020, Lebanon
[4] St Joseph Univ Med Campus, 650 Damascus Rd, Beirut, Lebanon
关键词
Flash-Free; Precoated brackets; Shear bond strength; Adhesive remnant index; ENAMEL; TIME; VIVO;
D O I
10.1016/j.ortho.2022.100705
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective > The aim of this in vitro study was to compare the shear bond strength (SBS) and the adhesive remnant index (ARI) of the metal APC (TM) Flash-Free adhesive system, the APC (TM) pre-coated adhesive system and a conventional uncoated system. Materials and methods > One hundred eighty-six freshly extracted human premolars were randomly divided into 3 groups and bonded by a single operator. Group A/Control Group (60 teeth): the manual bonding group treated with Transbond (TM) XT Light Cure Adhesive Paste (3M (TM) Unitek). Group B (60 teeth): treated with APC (TM) II metal maxillary premolar precoated brackets. Group C (66 teeth): treated with metal maxillary premolar APC Flash-Free brackets. The teeth were then stored in distilled water at 37 C for 24 hours, and five hundred cycles of thermocycling were performed. The Shear Bond Strength (SBS) test was performed using an Instron Universal Testing Machine, and the adhesive remnant index (ARI) was determined using a dental optical microscope at x25 magnification. Results > The mean shear bond strength values showed differences between the three types of brackets (P = 0.016; Anova). It was significantly higher with APC (TM) II and lower with APC Flash-Free brackets; however, no significant differences were found between conventional and APC Flash-Free brackets (P-value = 0.574). The distribution of the dichotomized ARI score was significantly different between the three brackets (P-value = 0.049). The ARI score for APC Flash-Free brackets was higher with no significant difference between the conventional system and APC brackets (P-value = 0.361). Conclusions > The mean SBS values were not significantly different between APC Flash-Free metal brackets and uncoated metal brackets. The APC Flash-Free metal system's bond failure occurred at the bracket-adhesive interface, with the highest percentage of teeth having more than 50% of the residual composite on the enamel after debonding.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Shear Bond Strength of Orthodontic Brackets with APC™ Flash-Free Adhesive: An In-Vitro Study
    Almoammar, Khalid A.
    Alkofide, Eman
    Alkhathlan, Abdullah
    Alateeq, Yazeed
    Alqahtani, Anas
    AlShaafi, Maan M.
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2017, 7 (08) : 671 - 677
  • [2] Comparative Evaluation of Shear Bond Strength, Enamel Microfracture, and Adhesive Remnant Index of APC Flash-Free System Versus Traditional Bonding: An In-Vitro Study
    Ranjan, Alok
    Khan, Waseem
    Achalkar, Poonam
    Pawar, Ankita
    Makdum, Dilip
    Kharkhar, Viraj
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (05)
  • [3] Shear Bond Strength, Bonding Time and Adhesive Remnant Index of Adhesive Precoated Flash Free Adhesive System vs Conventional Adhesive System using Metal Brackets: An In-vitro Study
    Borgikar, Hrishikesh
    Agrawal, Jiwanasha
    Agrawal, Manish
    Fulari, Sangamesh
    Nanjannawar, Lalita
    Shetti, Shraddha
    Kagi, Vishwal
    Shirkande, Amol
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2023, 17 (05) : ZC41 - ZC45
  • [4] Effect of Different Liquids and Thermal Aging Procedures on the Shear Bond Strength of APC II, APC Flash-Free, and Conventional Ceramic Brackets: An In Vitro Study
    Camci, Hasan
    Cevik, Seyda Canbaz
    TURKISH JOURNAL OF ORTHODONTICS, 2024, 37 (03) : 140 - 145
  • [5] Shear bond strength of adhesive precoated brackets: A comparative in vitro study
    Miller, Mary
    Mon, Htwe H.
    Xu, Xiaoming
    Chapple, Andrew
    Dupree, Peter
    Ballard, Richard W.
    Armbruster, Paul
    INTERNATIONAL ORTHODONTICS, 2023, 21 (02)
  • [6] Bond strength of pre-coated flash-free adhesive ceramic brackets. An in vitro comparative study on the second mandibular premolars
    Marc, Maria-Gabriela
    Bazert, Cedric
    Attal, Jean-Pierre
    INTERNATIONAL ORTHODONTICS, 2018, 16 (03) : 425 - 439
  • [7] Evaluation and comparison of shear bond strength and adhesive remnant index score in brackets bonded with probiotics impregnated orthodontic adhesive and commercially available orthodontic adhesive- An in vitro study
    Idaayath, M. Azmina
    Jnaneshwar, R. Poornima
    Krishnaraj, R.
    Ravi, K.
    INTERNATIONAL JOURNAL OF ORTHODONTIC REHABILITATION, 2023, 14 (01) : 18 - 25
  • [8] Debonding and adhesive remnant cleanup: an in vitro comparison of bond quality, adhesive remnant cleanup, and orthodontic acceptance of a flash-free product
    Gruenheid, Thorsten
    Sudit, Geoffrey N.
    Larson, Brent E.
    EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (05) : 497 - 502
  • [9] Comparative Evaluation of Shear Bond Strength, Adhesive Remnant Index and Cytotoxicity of Different Orthodontic Adhesives: An In-vitro Study
    Nookala, Havisha
    Jain, Ravindra Kumar
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2024, 18 (10) : ZC116 - ZC121
  • [10] Shear Bond Strength and Mode of Failure of Polypropylene Fibers in Orthodontic Flash-Free Adhesive
    Chaimaungchuen, Kitiporn
    Riddhabhaya, Apiwat
    Niyomtham, Nattisa
    Sirisoontorn, Irin
    POLYMERS, 2022, 14 (19)