Anterior Segment Optical Coherence Tomography Characteristics in an Asian Population

被引:17
作者
Sihota, Ramanjit [1 ,3 ]
Vashisht, Praveen
Sharma, Ajay [1 ,3 ]
Chakraborty, Swapna [1 ,3 ]
Gupta, Viney [1 ,3 ]
Pandey, Ravindra M. [2 ]
机构
[1] All India Inst Med Sci, Dr Rajendra Prasad Ctr Ophthalm Sci, Glaucoma Res Facil, New Delhi 110029, India
[2] All India Inst Med Sci, Dept Biostat, New Delhi 110029, India
[3] All India Inst Med Sci, Dr Rajendra Prasad Ctr Ophthalm Sci, Clin Serv, New Delhi 110029, India
关键词
anterior segment OCT; population; angle parameters; PRIMARY ANGLE-CLOSURE; RURAL-POPULATION; SOUTHERN INDIA; CHAMBER ANGLE; GLAUCOMA; EYE; PREVALENCE; GONIOSCOPY; DISEASE; IRIS;
D O I
10.1097/IJG.0b013e3182070cb1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To quantify the angle characteristics in an Indian population, and determine the prevalence of eyes at risk of angle closure. Materials and Methods: This population-based cohort study was carried out to evaluate individuals, 40 to 59 years of age, clinically. The individuals underwent anterior segment optical coherence tomography of their right eyes in the horizontal meridian, using the enhanced protocol. Results: The mean scleral spur angle for the population was 24.2 +/- 10.2 degrees, and a manually measured angle recess was 23.2 +/- 10.2 degrees, with a kappa value of agreement of 0.78, 85.7%. An angle of <20 degrees was seen in 154 eyes, 38.7%, 20 to 30 degrees in 154 eyes, 38.7%, and >30 degrees in 90 eyes, 22.6%. An anterior chamber angle of <20 degrees was significantly associated with age, sex, and a steep iris configuration. The scleral spur angle and the manually recorded anterior chamber angle recess correlated very well with all angle ultrasound biomicroscopy parameters, but showed the highest receiver operating characteristic curve with trabecular iris space area 500, r = 0.989 and angle opening distance 750, r = 0.943. On multivariate analysis, there was a significant correlation with trabecular iris space area, angle opening distance, and height. Conclusions: Of individuals, 38.7%, 40 to 60 years of age, were found to have an anterior chamber angle of <20 degrees, reflecting the high prevalence of primary angle closure and primary angle closure glaucoma in India.
引用
收藏
页码:180 / 185
页数:6
相关论文
共 50 条
[31]   Anterior Segment Optical Coherence Tomography Parameters in Phacomorphic Angle Closure and Mature Cataracts [J].
Mansouri, Mohammadreza ;
Ramezani, Farshid ;
Moghimi, Sasan ;
Tabatabaie, Ali ;
Abdi, Fatemeh ;
He, Mingguang ;
Lin, Shan C. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (11) :7403-7409
[32]   Deep Learning for Anterior Segment Optical Coherence Tomography to Predict the Presence of Plateau Iris [J].
Wanichwecharungruang, Boonsong ;
Kaothanthong, Natsuda ;
Pattanapongpaiboon, Warisara ;
Chantangphol, Pantid ;
Seresirikachorn, Kasem ;
Srisuwanporn, Chaniya ;
Parivisutt, Nucharee ;
Grzybowski, Andrzej ;
Theeramunkong, Thanaruk ;
Ruamviboonsuk, Paisan .
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2021, 10 (01) :1-10
[33]   Current and Potential Applications of Anterior Segment Optical Coherence Tomography in Contact Lens Fitting [J].
Luo, Zhonghui K. ;
Jacobs, Deborah S. .
SEMINARS IN OPHTHALMOLOGY, 2012, 27 (5-6) :133-137
[34]   Anterior segment optical coherence tomography of acute primary angle closure [J].
Zhang, Hai Tao ;
Xu, Liang ;
Cao, Wei Fang ;
Wang, Ya Xing ;
Jonas, Jost B. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (06) :825-831
[35]   Clinical and research applications of anterior segment optical coherence tomography - a review [J].
Ramos, Jose Luiz Branco ;
Li, Yan ;
Huang, David .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 37 (01) :81-89
[36]   Residual anterior chamber angle closure in narrow-angle eyes following laser peripheral iridotomy: anterior segment optical coherence tomography quantitative study [J].
Lee, Kyoung Sub ;
Sung, Kyung Rim ;
Kang, Sung Yong ;
Cho, Jung Woo ;
Kim, Dong Yoon ;
Kook, Michael S. .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2011, 55 (03) :213-219
[37]   Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopy in the Imaging of Anterior Segment Tumors [J].
Pavlin, Charles J. ;
Vasquez, Luz Maria ;
Lee, Richard ;
Simpson, E. Rand ;
Ahmed, Iqbal Ike K. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (02) :214-219
[38]   Identification of peripheral anterior synechia with anterior segment optical coherence tomography [J].
Yingying Dai ;
Shaodan Zhang ;
Meixiao Shen ;
Zi Jin ;
Yuheng Zhou ;
Shuling Ye ;
Chenhong Bao ;
Dexi Zhu .
Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 :2753-2759
[39]   Evaluation of changes of anterior segment parameters in patients with pseudoexfoliation syndrome after cataract surgery using anterior segment optical coherence tomography [J].
Wlaz, Aleksandra ;
Kustra, Agnieszka ;
Aung, Tin ;
Zarnowski, Tomasz .
SCIENTIFIC REPORTS, 2024, 14 (01)
[40]   Acute angle closure: qualitative and quantitative evaluation of the anterior segment using anterior segment optical coherence tomography [J].
Moghimi, Sasan ;
Zandvakil, Narges ;
Vahedian, Zakieh ;
Mohammadi, Massood ;
Fakhraie, Ghasem ;
Coleman, Anne L. ;
Lin, Shan C. .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (07) :615-622