Anterior Segment Optical Coherence Tomography Characteristics in an Asian Population

被引:17
作者
Sihota, Ramanjit [1 ,3 ]
Vashisht, Praveen
Sharma, Ajay [1 ,3 ]
Chakraborty, Swapna [1 ,3 ]
Gupta, Viney [1 ,3 ]
Pandey, Ravindra M. [2 ]
机构
[1] All India Inst Med Sci, Dr Rajendra Prasad Ctr Ophthalm Sci, Glaucoma Res Facil, New Delhi 110029, India
[2] All India Inst Med Sci, Dept Biostat, New Delhi 110029, India
[3] All India Inst Med Sci, Dr Rajendra Prasad Ctr Ophthalm Sci, Clin Serv, New Delhi 110029, India
关键词
anterior segment OCT; population; angle parameters; PRIMARY ANGLE-CLOSURE; RURAL-POPULATION; SOUTHERN INDIA; CHAMBER ANGLE; GLAUCOMA; EYE; PREVALENCE; GONIOSCOPY; DISEASE; IRIS;
D O I
10.1097/IJG.0b013e3182070cb1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To quantify the angle characteristics in an Indian population, and determine the prevalence of eyes at risk of angle closure. Materials and Methods: This population-based cohort study was carried out to evaluate individuals, 40 to 59 years of age, clinically. The individuals underwent anterior segment optical coherence tomography of their right eyes in the horizontal meridian, using the enhanced protocol. Results: The mean scleral spur angle for the population was 24.2 +/- 10.2 degrees, and a manually measured angle recess was 23.2 +/- 10.2 degrees, with a kappa value of agreement of 0.78, 85.7%. An angle of <20 degrees was seen in 154 eyes, 38.7%, 20 to 30 degrees in 154 eyes, 38.7%, and >30 degrees in 90 eyes, 22.6%. An anterior chamber angle of <20 degrees was significantly associated with age, sex, and a steep iris configuration. The scleral spur angle and the manually recorded anterior chamber angle recess correlated very well with all angle ultrasound biomicroscopy parameters, but showed the highest receiver operating characteristic curve with trabecular iris space area 500, r = 0.989 and angle opening distance 750, r = 0.943. On multivariate analysis, there was a significant correlation with trabecular iris space area, angle opening distance, and height. Conclusions: Of individuals, 38.7%, 40 to 60 years of age, were found to have an anterior chamber angle of <20 degrees, reflecting the high prevalence of primary angle closure and primary angle closure glaucoma in India.
引用
收藏
页码:180 / 185
页数:6
相关论文
共 16 条
[1]  
Console JW, 2008, BR J OPHTHALMOL, V92, P1575
[2]   Angle-closure glaucoma in an urban population in southern India - The Andhra Pradesh Eye Disease Study [J].
Dandona, L ;
Dandona, R ;
Mandal, P ;
Srinivas, M ;
John, RK ;
McCarty, CA ;
Rao, GN .
OPHTHALMOLOGY, 2000, 107 (09) :1710-1716
[3]   An ultrasound biomicroscopic study of the anterior segment in Indian eyes with primary angle-closure glaucoma [J].
Garudadri, CS ;
Chelerkar, V ;
Nutheti, R .
JOURNAL OF GLAUCOMA, 2002, 11 (06) :502-507
[4]   Gonioscopy in adult Chinese: The Liwan Eye Study [J].
He, Mingguang ;
Foster, Paul J. ;
Ge, Jian ;
Huang, Wenyong ;
Wang, Dandan ;
Friedman, David S. ;
Khaw, Peng T. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (11) :4772-4779
[5]   Prevalence of palteau Iris in primary angle closure suspects [J].
Kumar, Rajesh S. ;
Baskaran, Mani ;
Chew, Paul T. K. ;
Friedman, David S. ;
Handa, Swati ;
Lavanya, Raghavan ;
Sakata, Lisandro M. ;
Wong, Hon-Tym ;
Aung, Tin .
OPHTHALMOLOGY, 2008, 115 (03) :430-434
[6]   Plateau Iris in Asian Subjects With Primary Angle Closure Glaucoma [J].
Kumar, Rajesh S. ;
Tantisevi, Visanee ;
Wong, Melissa H. ;
Laohapojanart, Kobkuea ;
Chansanti, Orathai ;
Quek, Desmond T. ;
Koh, Victor T. ;
MohanRam, Lakshmana S. ;
Lee, Kelvin Y. ;
Rojanapongpun, Prin ;
Aung, Tin .
ARCHIVES OF OPHTHALMOLOGY, 2009, 127 (10) :1269-1272
[7]   Current approaches to the management of acute primary angle closure [J].
Lam, Dennis S. C. ;
Tham, Clement C. Y. ;
Lai, Jimmy S. M. ;
Leung, Dexter Y. L. .
CURRENT OPINION IN OPHTHALMOLOGY, 2007, 18 (02) :146-151
[8]   Screening of narrow angles in the Singapore population: Evaluation of new noncontact screening methods [J].
Lavanya, Raghavan ;
Foster, Paul J. ;
Sakata, Lisandro M. ;
Friedman, David S. ;
Kashiwagi, Kenji ;
Wong, Tien-Yin ;
Aung, Han T. ;
Alfred, Tamuno ;
Gao, Hong ;
Ee, Adrian G. ;
Seah, Steve K. ;
Aung, Tin .
OPHTHALMOLOGY, 2008, 115 (10) :1720-1727
[9]   Prospective comparison of ultrasound biomicroscopy and anterior segment optical coherence tomography for evaluation of anterior chamber dimensions in European eyes with primary angle closure [J].
Mansouri, K. ;
Sommerhalder, J. ;
Shaarawy, T. .
EYE, 2010, 24 (02) :233-239
[10]   Anterior Segment Optical Coherence Tomography as a Screening Tool for the Assessment of the Anterior Segment Angle [J].
Pekmezci, Melike ;
Porco, Travis C. ;
Lin, Shan C. .
OPHTHALMIC SURGERY LASERS & IMAGING, 2009, 40 (04) :389-398