The effect of simulated inflammatory conditions and pH on fretting corrosion of CoCrMo alloy surfaces

被引:53
作者
Liu, Yangping [1 ,2 ]
Gilbert, Jeremy L. [1 ,2 ,3 ,4 ]
机构
[1] Syracuse Univ, Syracuse Biomat Inst, Syracuse, NY 13244 USA
[2] Syracuse Univ, Dept Biomed & Chem Engn, Syracuse, NY 13244 USA
[3] Clemson Univ, Dept Bioengn, Clemson, SC 29634 USA
[4] Med Univ South Carolina, Dept Orthopaed, Charleston, SC 29425 USA
关键词
Fretting corrosion; CoCrMo alloy; Inflammation; PH; Corrosion; LOCAL TISSUE REACTION; TOTAL HIP-REPLACEMENT; IN-VIVO; PSEUDOTUMOR FORMATION; ORTHOPEDIC IMPLANTS; BOVINE SERUM; BODY; ARTHROPLASTY; COMPONENTS; BEHAVIOR;
D O I
10.1016/j.wear.2017.08.011
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Inflammation may develop due to the implantation of orthopedic devices and inflammatory cell-based chemical species may affect the fretting corrosion behavior of CoCrMo alloy. The effect of simulated inflammatory (SI) conditions and acid on the fretting corrosion behavior of CoCrMo was studied. SI conditions included phosphate buffered saline (PBS) with H2O2 and PBS with Fenton reaction (Fe3+, H2O2). Fretting corrosion behavior of CoCrMo alloy was significantly affected by both the Fenton reaction-based solution chemistry and potential. The Fenton reaction increased the oxidizing power of the solution and led to a significant rise in open circuit potential (OCP) during fretting corrosion compared to PBS and pH 3 solutions (p < 0.05). SI conditions also altered the oxide film characteristics, altering both the fretting corrosion response of CoCrMo alloy (smaller fretting currents by about 50%) and the frictional behavior compared to the PBS case. Fretting current density in Fenton reaction conditions was significantly smaller compared to PBS conditions at all potentials, indicating the oxide film was less protective due to the presence of Fenton reactions. A significantly higher coefficient of friction was observed in Fenton reaction solutions at -0.4 V (0.5) and -0.6 V (0.55) compared to all other conditions. This appears to be related to the oxide formation potential (-0.4 V) and the effects of solution chemistry on sliding mechanics. Passivation of oxide film was the strongest in pH 3 condition, where baseline current density was the lowest at 0.6 V compared to that of other solutions (p < 0.05).
引用
收藏
页码:302 / 311
页数:10
相关论文
共 50 条
[1]   REVIEW - ANODIC-OXIDATION OF TITANIUM AND ITS ALLOYS [J].
ALADJEM, A .
JOURNAL OF MATERIALS SCIENCE, 1973, 8 (05) :688-704
[2]  
[Anonymous], 2017, THESIS NANJING U
[3]   Corrosion Damage and Wear Mechanisms in Long-Term Retrieved CoCr Femoral Components for Total Knee Arthroplasty [J].
Arnholt, Christina M. ;
MacDonald, Daniel W. ;
Malkani, Arthur L. ;
Klein, Gregg R. ;
Rimnac, Clare M. ;
Kurtz, Steven M. ;
Kocagoz, Sevi B. ;
Gilbert, Jeremy L. .
JOURNAL OF ARTHROPLASTY, 2016, 31 (12) :2900-2906
[4]   High incidence of pseudotumour formation after large-diameter metal-on-metal total hip replacement A PROSPECTIVE COHORT STUDY [J].
Bosker, B. H. ;
Ettema, H. B. ;
Boomsma, M. F. ;
Kollen, B. J. ;
Maas, M. ;
Verheyen, C. C. P. M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (06) :755-761
[5]  
Cerquiglini A, 2016, J BIOMED MAT RES B
[6]   Corrosion behaviour of CoCrMo implant alloy during fretting in bovine serum [J].
Contu, F ;
Elsener, B ;
Böhni, H .
CORROSION SCIENCE, 2005, 47 (08) :1863-1875
[7]   Electrochemical behavior of CoCrMo alloy in the active state in acidic and alkaline buffered solutions [J].
Contu, F ;
Elsener, B ;
Böhni, H .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2003, 150 (09) :B419-B424
[8]   Adverse Local Tissue Reaction Arising from Corrosion at the Femoral Neck-Body Junction in a Dual-Taper Stem with a Cobalt-Chromium Modular Neck [J].
Cooper, H. John ;
Urban, Robert M. ;
Wixson, Richard L. ;
Meneghini, R. Michael ;
Jacobs, Joshua J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (10) :865-872
[9]  
Di Laura A, 2015, J BIOMED MAT RES B
[10]   Computational hip joint simulator for wear and heat generation [J].
Fialho, Jorge C. ;
Fernandes, Paulo R. ;
Eca, Luis ;
Folgado, Joao .
JOURNAL OF BIOMECHANICS, 2007, 40 (11) :2358-2366