Data analysis using Hilbert-Huang transform for partial discharge in low voltage motors

被引:0
作者
Tang, Ya-Wen [1 ]
Tai, Cheng-Chi [1 ]
Su, Ching-Chau [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Elect Engn, Tainan 70101, Taiwan
来源
2007 INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS APPLICATIONS TO POWER SYSTEMS, VOLS 1 AND 2 | 2007年
关键词
partial discharge (PD); acoustic emission (AE); Hilbert-Huang Transform (HHT);
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Over the course of the past 20 years, the number of signal processing methods used to analyze the partial discharge (PD) of electrical equipments has greatly increased. In this paper, we analyze and compare the PD signals from acoustic emission (AE) and high-frequency current transformer (HFCT) measurements with Hilbert-Huang Transforms (HHT). The HHT demonstrates several excellent advantages in the PD signal analysis application.
引用
收藏
页码:198 / 201
页数:4
相关论文
共 50 条
  • [31] Applying Hilbert-Huang Transform on PartialDischarge Pattern Recognition of a Gas Insulated Switchgear
    Chang, Hong-Chan
    Gu, Feng-Chang
    Kuo, Cheng-Chien
    PROCEEDINGS OF THE 2012 IEEE INTERNATIONAL POWER MODULATOR AND HIGH VOLTAGE CONFERENCE, 2012, : 165 - 168
  • [32] Time-Frequency Analysis of Scalp EEG With Hilbert-Huang Transform and Deep Learning
    Zheng, Jingyi
    Liang, Mingli
    Sinha, Sujata
    Ge, Linqiang
    Yu, Wei
    Ekstrom, Arne
    Hsieh, Fushing
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (04) : 1549 - 1559
  • [33] Applications of Hilbert-Huang transform to non-stationary financial time series analysis
    Huang, NE
    Wu, ML
    Qu, WD
    Long, SR
    Shen, SSP
    APPLIED STOCHASTIC MODELS IN BUSINESS AND INDUSTRY, 2003, 19 (03) : 245 - 268
  • [34] Fault Diagnosis for High Voltage Circuit Breaker Based on Hilbert-Huang Transform and Support Vector Machine
    Hou, Chunguang
    Jia, Maoyuan
    Han, Ying
    Cao, Yundong
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT-SWITCHING TECHNOLOGY (ICEPE-ST), 2017, : 985 - 989
  • [35] Analysis of signal characteristics of swirlmeter in oscillatory flow based on Hilbert-Huang Transform (HHT)
    Peng, Jiegang
    Zhang, Gang
    MEASUREMENT, 2012, 45 (07) : 1765 - 1781
  • [36] Bearing failures detection in induction motors using the stator current analysis based on Hilbert Huang transform
    Saadi, Mohamed-Nacer
    Boukhenaf, Messaoud
    Redjati, Abdelghani
    Guersi, Noureddine
    2017 EUROPEAN CONFERENCE ON ELECTRICAL ENGINEERING AND COMPUTER SCIENCE (EECS), 2017, : 101 - 106
  • [37] Identification of low-frequency oscillations in power system based on improved Hilbert-Huang transform
    Ma, Yanfeng
    Zhao, Shuqiang
    Gaodianya Jishu/High Voltage Engineering, 2012, 38 (06): : 1492 - 1499
  • [38] Frequency Analysis of Disturbance Torque Exerted on a Carriage Arm in Hard Disk Drives Using Hilbert-Huang Transform
    Koganezawa, Shinji
    Tsuda, Shotaro
    Tani, Hiroshi
    Lu, Renguo
    Tagawa, Norio
    IEEE TRANSACTIONS ON MAGNETICS, 2018, 54 (11)
  • [39] Analysis of partial discharge by Wavelet-Hilbert transform
    Sarikhani, Ali
    Reihani, Ehsan
    Nabizadeh, Nooshin
    Hooshmand, Ali
    Davodi, Moez
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2009, 19 (08): : 1140 - 1152
  • [40] Boundary extension for Hilbert-Huang transform inspired by gray prediction model
    He, Zhi
    Shen, Yi
    Wang, Qiang
    SIGNAL PROCESSING, 2012, 92 (03) : 685 - 697