Elimination of zero sequence circulating currents in paralleled three-level T-type inverters with a model predictive control strategy

被引:24
作者
Wang, Xiaodong [1 ,2 ]
Zou, Jianxiao [1 ]
Peng, Ying [1 ]
Xie, Chuan [1 ]
Li, Kai [1 ]
Zapata, Josep Maria Guerrero [3 ]
机构
[1] Univ Elect Sci & Technol China, Sch Automat Engn, Chengdu, Sichuan, Peoples R China
[2] China Acad Engn Phys, Inst Mat, Mianyang, Peoples R China
[3] Aalborg Univ, Dept Energy Technol, Aalborg, Denmark
关键词
electric current control; switching convertors; power grids; predictive control; power harmonic filters; invertors; feedback; zero sequence; three-level T-type inverters; model predictive control strategy; system power rating; common DC-link; novel model predictive control based strategy; parallel operating 3LT; common-mode voltages; CMVs; neutral point potentials; paralleled; 3LT; potential exciting sources; MPC-based zero CMV method; cost function; closed-loop ZSCC feedback control method; MPC-based ZSCC elimination strategy; load current tracking; NPP balance control; GRID-CONNECTED INVERTERS; CONVERTERS; PWM; DESIGN;
D O I
10.1049/iet-pel.2018.5324
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The configuration of modular paralleled three-level T-type inverters (3LT(2)Is) has been widely utilised to extend the system power rating. However, zero sequence circulating currents (ZSCCs) are generated when sharing the common DC-link and the AC side without isolated transformers. This study presents a novel model predictive control (MPC) based strategy to eliminate the ZSCC in parallel operating 3LT(2)Is. Both the differences of common-mode voltages (CMVs) and neutral point potentials (NPPs) between paralleled 3LT(2)Is are investigated to be the potential exciting sources of the ZSCC based on the developed model of the ZSCC. According to this conclusion, an MPC-based zero CMV method which adds an additional term to the cost function is used to reduce the differences of CMVs between paralleled 3LT(2)Is. Besides, a closed-loop ZSCC feedback control method is further introduced to compensate the ZSCC by modifying the cost function. With the proposed MPC-based ZSCC elimination strategy, the ZSCC between the paralleled 3LT(2)Is can be effectively eliminated in both steady and dynamic states. Besides, good performances can be achieved for both load current tracking and NPP balance control. Simulation and experimental results validate the effectiveness of the proposed ZSCC elimination strategy.
引用
收藏
页码:2573 / 2581
页数:9
相关论文
共 50 条
[21]   Optimized Asymmetrical Switching Sequences-Based Model-Predictive Control for Three-Level T-Type Inverters [J].
Guo, Zhikang ;
Zhang, Weifeng ;
Ling, Zang ;
Li, Zhaoxun ;
Wu, Xiang ;
Tan, Guojun .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2024, 12 (03) :2661-2673
[22]   Analysis and Compensation of Inverter Nonlinearity for Three-Level T-Type Inverters [J].
Kim, Hyeon-Sik ;
Kwon, Yong-Cheol ;
Chee, Seung-Jun ;
Sul, Seung-Ki .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (06) :4970-4980
[23]   A Fixed Switching Frequency Model Predictive Control for T-type Three-level Three-phase Grid-connected Inverters [J].
Yang, Yong ;
Fan, Mingdi ;
Xie, Menxi ;
Zhu, Zhongkui .
PROCEEDINGS OF THE 2017 12TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2017, :1137-1142
[24]   The Tolerance Control Method Based on Zero-Sequence Circulating Current Suppression for Parallel T-Type Three-Level Rectifiers [J].
Chen, Zhiyuan ;
Li, Xiaoyan ;
Xing, Xiangyang ;
Fu, Youliang ;
Zhang, Boxue ;
Pang, Xianzhe ;
Zhang, Chenghui .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2022, 10 (04) :4383-4394
[25]   Online Feedback Dead Time Compensation Strategy for Three-Level T-Type Inverters [J].
Wang, Dafang ;
Wang, Mingyu ;
Shen, Yuelei ;
Li, Qi ;
Liang, Xiu .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (09) :7260-7268
[26]   Enhanced Sliding Mode Control for Dual MPPT Systems Integrated with Three-Level T-Type PV Inverters [J].
Bagheri, Farzaneh ;
Bonaldo, Jakson ;
Guler, Naki ;
Rivera, Marco ;
Wheeler, Patrick ;
Lima, Rogerio .
ENERGIES, 2025, 18 (13)
[27]   Fast Finite-Switching-State Model Predictive Control Method Without Weighting Factors for T-Type Three-Level Three-Phase Inverters [J].
Yang, Yong ;
Wen, Huiqing ;
Fan, Mingdi ;
Xie, Menxi ;
Chen, Rong .
IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2019, 15 (03) :1298-1310
[28]   Fault-tolerant compensation control for T-type three-level inverter with zero-sequence voltage injection [J].
Zhang, Jianzhong ;
Hu, Lucai ;
Xu, Shuai ;
Deng, Fujin .
IET POWER ELECTRONICS, 2019, 12 (14) :3774-3781
[29]   Circulating Current Analysis and the Improved D- Digital Control Strategy for Multiparalleled Three-Level T-Type Grid-Connected Inverters [J].
Ren, Biying ;
Sun, Xiangdong ;
Yu, Majing ;
Liu, Jiang ;
Zhang, Qi .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (04) :2810-2821
[30]   Decoupled Continuous Control Set Model Predictive Control for T-Type Three-Phase Four-Leg Three-Level Inverters Driving Constant Power Loads [J].
Zhu, Yi ;
Wen, Huiqing ;
Yang, Yong ;
Mao, Jianliang ;
Wang, Pan ;
Huang, Weiguo ;
Rodriguez, Jose .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (06) :7002-7015