On the vectorial calibration of a vibrating sample magnetometer for thin film measurements

被引:8
作者
Bolhuis, T
Abelmann, L
Lodder, JC
Samwel, EO
机构
[1] Univ Twente, MESA Res Inst, NL-7500 AE Enschede, Netherlands
[2] ADE Technol Inc, Digital Measurement Syst Div, Newton, MA 02166 USA
关键词
calibration; vector VSM; cross talk; thin film; demagnetisation; ME-tape;
D O I
10.1016/S0304-8853(98)00451-X
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A calibration method for the biaxial vector Vibrating Sample Magnetometer (VSM) is proposed to reduce the so-called cross talk' error, often observed during angular measurements on magnetic thin films. The coil system of the biaxial vector VSM consists of two sets of coils, one for each of the two co-ordinate axes. The method takes into account that each coil set is sensitive to all components of the magnetisation vector and moreover that the sensitivity to the components parallel and perpendicular to the film plane can be different. A correction for demagnetisation should be used to compensate the fact that the sample used for the calibration cannot be fully saturated with an applied field at angles close to the normal of the film plane. Curve-fitting on the sensitivity curves is used to reduce noise. These procedures result in a calibration which reduces the cross talk by a factor 4-8 depending on the coil configuration and the size and shape of the samples used. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:332 / 336
页数:5
相关论文
共 50 条
  • [1] A calibration round-robin protocol for nanoindentation measurements of thin film coatings
    Cabibbo, M.
    Spigarelli, S.
    EUROPEAN CONFERENCE ON NANO FILMS - ECNF2012, 2013, 40 : 1 - 8
  • [2] Wide-Range Calibration of Magnetic Moments for Vibrating Sample Magnetometers
    Zhang, Zhigao
    Xu, Zhiyi
    He, Jian
    Lu, Jun
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [3] Design and development of a first order reversal curve measurement enabled variable temperature vibrating sample magnetometer
    Pratheek, Hanamanta
    Badiger, Hanamanta
    Sah, Nutan Kumari
    Joshi, Rajeev S.
    Bhat, Subray, V
    Hegde, Balachandra G.
    PHYSICA SCRIPTA, 2024, 99 (08)
  • [4] Conduction based calibration of handmade platinum thin film heat transfer gauges for transient measurements
    Kumar, Rakesh
    Sahoo, Niranjan
    Kulkarni, Vinayak
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (9-10) : 2707 - 2713
  • [5] The Components of Variance for Calibration Methods of Thin Film CdTe Photovoltaic Modules
    Pratt, Larry
    Riedel, Nicholas
    Yamasaki, Michael
    Plass, Martin
    2013 IEEE 39TH PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2013, : 639 - 641
  • [6] Calibration Technique for THz Time-Domain Spectrometers Enabling Vectorial Scattering Parameter Measurements
    Mueh, Mario
    Brandl, Susanne
    Hinz, Philipp
    Waldschmidt, Christian
    Damm, Christian
    IEEE MICROWAVE AND WIRELESS COMPONENTS LETTERS, 2021, 31 (06) : 805 - 807
  • [7] Preliminary study of calibration system for PZT thin film micro force sensor
    Cui, Yan
    Dong, Weijie
    Liu, Mengwei
    Wang, Minriu
    Wang, Jing
    Wang, Xiaodong
    Wang, Liding
    FERROELECTRICS, 2007, 358 : 904 - +
  • [8] Magnetic Property Calibration of Low-Permeability Materials for Vibrating Sample Magnetometers Using Neural Networks
    Kong, Xiaohan
    Uehara, Yuji
    Terauchi, Naoya
    Sato, Natsuko
    Matsuda, Yoshibumi
    Nagano, Masanori
    Igarashi, Hajime
    IEEE TRANSACTIONS ON MAGNETICS, 2024, 60 (12)
  • [9] Fabrication and Calibration of Cu-Ni Thin Film Thermocouples
    Guo Hang
    Jiang Jun Ying
    Liu Jia Xing
    Nie Zhi Hua
    Ye Fang
    Ma Chong Fang
    RENEWABLE AND SUSTAINABLE ENERGY II, PTS 1-4, 2012, 512-515 : 2068 - +
  • [10] Radiation based calibration of thin film gauge for transient measurement
    Alam, Tanweer
    Kumar, Rakesh
    MEASUREMENT, 2018, 128 : 352 - 361