Estimate of the Shielding Parameters for the Heavy Ion Accelerator Facility by Using a Monte Carlo Simulation

被引:0
|
作者
Nakao, Noriaki [1 ]
Lee, Hee-Seock [1 ]
Cho, Woon-Kab [2 ]
机构
[1] PAL, Pohang 790784, South Korea
[2] Korea Inst Nucl Safety, Taejon 305338, South Korea
关键词
Heavy ion; RI beam; Shielding; Attenuation length; Neutron; Dose rate; Monte Carlo; PHITS;
D O I
10.3938/jkps.59.546
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
For a conceptual shielding design of the Korea Rare Isotope Accelerator (KoRIA) project, the shielding parameters for the source terms and the attenuation lengths for a simple exponential formula were determined based on simulations using the PHITS Monte Carlo code. Simulations were performed for angular and energy spectra of secondary neutrons from an iron target of full stopping thickness or a thin graphite target bombarded by heavy ions of (238)U, (86)Kr, (48)Ca (200 similar to 270 MeV/u) and protons (600 MeV). Using the thus obtained neutron energy spectra for various angles, we also simulated attenuations of high-energy neutrons through 8-m-thick shields of concrete or iron. By fitting the exponential formula to the attenuation profiles, we obtained shielding parameters for various combinations of projectile, target, angle and shielding material. The parameters were summarized for a point beam loss and for a uniform beam loss along the accelerator beam line. Appropriate shielding thicknesses of concrete and iron could be estimated comparatively easily for various conditions in the heavy ion accelerator facility.
引用
收藏
页码:546 / 552
页数:7
相关论文
共 50 条
  • [32] CHARACTERISATION OF THE TRIUMF NEUTRON FACILITY USING A MONTE CARLO SIMULATION CODE
    Monk, S. D.
    Abram, T.
    Joyce, M. J.
    RADIATION PROTECTION DOSIMETRY, 2015, 164 (03) : 228 - 238
  • [33] Monte Carlo method for calculating the skyshine of electron accelerator shielding room
    Kong, CC
    Li, QF
    Du, TB
    Cheng, C
    Chen, HB
    Tang, CX
    Zhu, L
    Pei, ZG
    Ming, SJ
    Zhang, H
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2004, 28 (04): : 431 - 436
  • [34] A Monte Carlo Simulation Dataset of Radiation Field Parameters for a Simple Nuclear Facility Scenario
    Hao, Yisheng
    Wu, Zhen
    Pu, Yanheng
    Zhou, Yang
    Qiu, Rui
    Zhang, Hui
    Li, Junli
    SCIENTIFIC DATA, 2024, 11 (01)
  • [35] Monte Carlo Simulation of Linear Accelerator for Dosimetry Analysis
    Francis, Seenia
    Suresh, Darshana
    Nath, Shalini
    Lakshmi, Saai D. R.
    Jayaraj, P. B.
    Puzhakkal, Niyas
    Pournami, P. N.
    2021 6TH INTERNATIONAL CONFERENCE FOR CONVERGENCE IN TECHNOLOGY (I2CT), 2021,
  • [36] Monte Carlo simulation of electron beams from an accelerator head using PENELOPE
    Sempau, J
    Sánchez-Reyes, A
    Salvat, F
    ben Tahar, HO
    Jiang, SB
    Fernández-Varea, JM
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04): : 1163 - 1186
  • [37] Monte-Carlo Simulation of Hard Probes in Heavy-Ion Collisions
    Schenke, Bjoern
    Jeon, Sangyong
    Gale, Charles
    INTERNATIONAL NUCLEAR PHYSICS CONFERENCE 2010 (INPC): HOT AND DENSE QCD, 2011, 312
  • [38] Erratum: Activation evaluation of Siemens linear accelerator using Monte Carlo simulation
    Young-Jae Jang
    Na Hye Kwon
    Seong Hee Park
    Yona Choi
    Hyungjoon Yu
    Kum Bae Kim
    Dong Wook Kim
    Sang Hyoun Choi
    Journal of the Korean Physical Society, 2022, 81 : 1188 - 1188
  • [39] A Study on Radiation Shielding Ability of Composite Materials Using Monte Carlo Simulation
    Cha, Ju-Hee
    Jeon, Han-Yong
    POLYMER-KOREA, 2019, 43 (05) : 798 - 806
  • [40] Measurement of parameters in discrete program using Monte Carlo simulation
    Xiao, Bo
    Huang, Jiaofeng
    Zhang, Xuan
    Jing, Yuefeng
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2013, 25 (01): : 138 - 142