Improved DNA fragment length estimation in capillary electrophoresis

被引:11
作者
Akbari, Akbar [1 ]
Marthinsen, Gunnhild [2 ]
Lifield, Jan T. [2 ]
Albregtsen, Fritz [1 ]
Wennerberg, Liv [2 ]
Stenseth, Nils C. [3 ]
Jakobsen, Kjetill S. [3 ]
机构
[1] Univ Oslo, Dept Informat, N-0316 Oslo, Norway
[2] Univ Oslo, NCB, Nat Hist Museum, N-0316 Oslo, Norway
[3] Univ Oslo, CEES, Dept Biol, N-0316 Oslo, Norway
关键词
adaptive weighted least squares; internal size standards; local southern; PCR; STIR;
D O I
10.1002/elps.200700523
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In CE the charged DNA strands are fractionated according to fragment lengths as they migrate through the capillary, since shorter DNA fragments pass through the sieving matrix faster. Multiplexed internal size standards are used to estimate the size of unknown DNA fragments. In the literature there are statements about migration abnormalities for the 250 and 340 bp fragments in the GeneScan-500 (GS500) internal size standards. Such anomalous migration of size standards could obviously introduce errors in the estimation of unknown fragments. Therefore, a number of analysis programs simply exclude some of these fragments. In the present work we first evaluate the effect of excluding each of the fragments in the internal size standards used in CE. Next, a method which is based on estimating the true values of the anomalous fragments is presented. The results obtained by the new method indicate a significant improvement compared to results obtained when one (or both) of the anomalous fragments in GS500 is (are) excluded or included when estimating the size of unknown DNA fragments. In the higher-molecular-weight region, the average error is reduced from 1.91 bp in ABI GeneMapper (excluding 250 bp) to 0.15 bp in the new method (using the estimated values for 250 and 340 bp). In the lower-molecular-weight region, excluding both fragments will improve the results by an average of 0.74 bp compared to ABI GeneMapper.
引用
收藏
页码:1273 / 1285
页数:13
相关论文
共 15 条
[1]  
Akbari A, 2004, P ANN INT IEEE EMBS, V26, P2852
[2]  
Akbari A, 2002, ELECTROPHORESIS, V23, P176, DOI 10.1002/1522-2683(200202)23:2<176::AID-ELPS176>3.0.CO
[3]  
2-1
[4]  
[Anonymous], 1989, Molecular Cloning
[5]  
*APPL BIOS, 2001, ABI PRISM 3100 GEN A
[6]   Forensic DNA typing by capillary electrophoresis using the ABI Prism 310 and 3100 genetic analyzers for STR analysis [J].
Butler, JM ;
Buel, E ;
Crivellente, F ;
McCord, BR .
ELECTROPHORESIS, 2004, 25 (10-11) :1397-1412
[7]  
EISEN JA, 1999, MICROSATELLITES EVOL
[8]  
ELDER JK, 1987, NUCL ACID PROTEIN SE
[9]  
Kirby LT, 1990, DNA FINGERPRINTING I
[10]  
KLEIN SB, 2003, FORENSIC SCI COMMUNI, V5