Towards a New Qualitative Screening Assay for Synthetic Cannabinoids Using Metabolomics and Machine Learning

被引:9
作者
Streun, Gabriel L. [1 ]
Steuer, Andrea E. [1 ]
Poetzsch, Sandra N. [1 ]
Ebert, Lars C. [2 ]
Dobay, Akos [3 ]
Kraemer, Thomas [1 ]
机构
[1] Univ Zurich, Zurich Inst Forens Med, Dept Forens Pharmacol & Toxicol, Zurich, Switzerland
[2] Univ Zurich, Zurich Inst Forens Med, Dept Forens Imaging Virtopsy, Zurich, Switzerland
[3] Univ Zurich, Zurich Inst Forens Med, Dept Forens Genet, Zurich, Switzerland
关键词
synthetic cannabinoids; metabolomics; random forests; urine screening; URINE SAMPLES; MASS-SPECTROMETRY; DETECT;
D O I
10.1093/clinchem/hvac045
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Synthetic cannabinoids (SCs) are steadily emerging on the drug market. To remain competitive in clinical or forensic toxicology, new screening strategies including high-resolution mass spectrometry (HRMS) are required. Machine learning algorithms can detect and learn chemical signatures in complex datasets and use them as a proxy to predict new samples. We propose a new screening tool based on a SC-specific change of the metabolome and a machine learning algorithm. Methods Authentic human urine samples (n = 474), positive or negative for SCs, were used. These samples were measured with an untargeted metabolomics liquid chromatography (LC)-quadrupole time-of-flight-HRMS method. Progenesis QI software was used to preprocess the raw data. Following feature engineering, a random forest (RF) model was optimized in R using a 10-fold cross-validation method and a training set (n = 369). The performance of the model was assessed with a test (n = 50) and a verification (n = 55) set. Results During RF optimization, 49 features, 200 trees, and 7 variables at each branching node were determined as most predictive. The optimized model accuracy, clinical sensitivity, clinical specificity, positive predictive value, and negative predictive value were 88.1%, 83.0%, 92.7%, 91.3%, and 85.6%, respectively. The test set was predicted with an accuracy of 88.0%, and the verification set provided evidence that the model was able to detect cannabinoid-specific changes in the metabolome. Conclusions An RF approach combined with metabolomics enables a novel screening strategy for responding effectively to the challenge of new SCs. Biomarkers identified by this approach may also be integrated in routine screening methods.
引用
收藏
页码:848 / 855
页数:8
相关论文
共 34 条
  • [1] What about the herb? A new metabolomics approach for synthetic cannabinoid drug testing
    Bijlsma, Lubertus
    Gil-Solsona, Ruben
    Hernandez, Felix
    Vicente Sancho, Juan
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (21) : 5107 - 5112
  • [2] Random forests
    Breiman, L
    [J]. MACHINE LEARNING, 2001, 45 (01) : 5 - 32
  • [3] Random forests
    Breiman, L
    [J]. MACHINE LEARNING, 2001, 45 (01) : 5 - 32
  • [4] Activity-Based Detection of Consumption of Synthetic Cannabinoids in Authentic Urine Samples Using a Stable Cannabinoid Reporter System
    Cannaert, Annelies
    Franz, Florian
    Auwaerter, Volker
    Stove, Christophe P.
    [J]. ANALYTICAL CHEMISTRY, 2017, 89 (17) : 9527 - 9536
  • [5] Variable Data Independent Acquisition and Data Mining Exploring Feature-Based Molecular Networking Analysis for Untargeted Screening of Synthetic Cannabinoids in Oral Fluid
    Cavalcanti, Gustavo de Albuquerque
    Borges, Ricardo Moreira
    Alves Carneiro, Gabriel Reis
    Padilha, Monica Costa
    Gualberto Pereira, Henrique Marcelo
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2021, 32 (09) : 2417 - 2424
  • [6] Emerging drugs of abuse: current perspectives on synthetic cannabinoids
    Debruyne, Daniele
    Le Boisselier, Reynald
    [J]. SUBSTANCE ABUSE AND REHABILITATION, 2015, 6 : 113 - 129
  • [7] European Monitoring Centre for Drugs and Drug Addiction, 2021, EUR MON CTR DRUGS DR
  • [8] Development of a fragmentation pattern of synthetic cannabinoids based on electrospray ionization mass spectrometry in positive ion mode to screen synthetic cannabinoids in illicit products
    Fan, Yilei
    Zong, Xingsen
    Liu, Jiwu
    Ke, Xing
    Huang, Zhongping
    Xu, Yu
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 193
  • [9] Retrospective analysis of new psychoactive substances in blood samples of German drivers suspected of driving under the influence of drugs
    Fels, Helena
    Herzog, Josefine
    Skopp, Gisela
    Holzer, Anna
    Paul, Liane D.
    Graw, Matthias
    Musshoff, Frank
    [J]. DRUG TESTING AND ANALYSIS, 2020, 12 (10) : 1470 - 1476
  • [10] Preparation of urine samples prior to targeted or untargeted metabolomics mass-spectrometry analysis
    Fernandez-Peralbo, M. A.
    Luque de Castro, M. D.
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2012, 41 : 75 - 85