Determination of uranium in seawater by flow-injection preconcentration on dodecylamidoxime-impregnated resin and spectrophotometric detection

被引:37
作者
Oguma, Koichi [1 ]
Suzuki, Toshihiro [1 ]
Saito, Kyoichi [1 ]
机构
[1] Chiba Univ, Grad Sch Engn, Dept Appl Chem & Biotechnol, Inage Ku, Chiba 2638522, Japan
关键词
Uranium; Seawater; Dodecylamidoxime-impregnated resin; Flow injection analysis; Spectrophotometric detection; SOLID-PHASE EXTRACTION; ENVIRONMENTAL-SAMPLES; NATURAL-WATERS; ICP-MS; RECOVERY; THORIUM;
D O I
10.1016/j.talanta.2010.12.020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection method has been developed for the determination of uranium in seawater combining the on-line preconcentration with spectrophotometric detection. An aliquot (10 mL) of the seawater sample adjusted to pH 5.5 was injected into the analytical system and uranium was adsorbed on the column packed with styrene-divinylbenzene copolymer resin (Bio-Beads SM-2) modified with dodecylamidoxime which showed high selectivity to uranium. Uranium was then eluted with 0.01 M hydrochloric acid and detected spectrophotometrically after the reaction with Chlorophosphonazo III. Interference from calcium and strontium was masked with cyclohexanediaminetetraacetic acid added to the chromogenic reagent solution. The sample throughput, the detection limit (3 sigma), and the preconcentration factor were 23 per hour, 0.13 mu g/L, and 20, respectively, when the sample injection volume was kept at 10 mL. The precision at the 2 mu g/L level was less than 4% (RSD). The proposed method was applied to the determination of uranium in the seawater samples collected off the Boso peninsula, Japan and the uranium concentration was found to be ca. 3 mu g/L, which is close to the literature data. The yield of the recovery test ranged from 95% to 99%. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1209 / 1214
页数:6
相关论文
共 25 条
  • [1] Determination of uranium by flow injection inductively coupled plasma mass spectrometry
    Aldstadt, JH
    Kuo, JM
    Smith, LL
    Erickson, MD
    [J]. ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) : 135 - 143
  • [2] ONLINE TRACE ENRICHMENT AND DETERMINATION OF URANIUM IN WATERS BY FLOW-INJECTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY
    DADFARNIA, S
    MCLEOD, CW
    [J]. APPLIED SPECTROSCOPY, 1994, 48 (11) : 1331 - 1336
  • [3] Chemical aspects of uranium recovery from seawater by amidoximated electron-beam-grafted polypropylene membranes
    Das, Sadananda
    Pandey, A. K.
    Athawale, Anjali
    Kumar, Virendra
    Bhardwaj, Y. K.
    Sabharwal, S.
    Manchanda, V. K.
    [J]. DESALINATION, 2008, 232 (1-3) : 243 - 253
  • [4] STUDIES ON SELECTIVE ADSORPTION RESINS .12. PREPARATION OF ADSORPTION RESINS FOR URANIUM IN SEA-WATER
    EGAWA, H
    HARADA, H
    NONAKA, T
    [J]. NIPPON KAGAKU KAISHI, 1980, (11) : 1767 - 1772
  • [5] SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF CALCIUM + MAGNESIUM WITH CHLOROPHOSPHONAZO 3
    FERGUSON, JW
    RICHARD, JJ
    BANKS, CV
    OLAUGHLIN, JW
    [J]. ANALYTICAL CHEMISTRY, 1964, 36 (04) : 796 - &
  • [6] Simultaneous spectrophotometric determination of trace amounts of uranium, thorium, and zirconium using the partial least squares method after their preconcentration by α-benzoin oxime modified Amberlite XAD-2000 resin
    Ghasemi, Jahan B.
    Zolfonoun, E.
    [J]. TALANTA, 2010, 80 (03) : 1191 - 1197
  • [7] HELFFERICH F, 1962, ION EXCHANGE, P424
  • [8] Determination of trace metals in seawater by on-line column preconcentration inductively coupled plasma mass spectrometry using metal alkoxide glass immobilized 8-quinolinol
    Hirata, S
    Kajiya, T
    Takano, N
    Aihara, M
    Honda, K
    Shikino, O
    Nakayama, E
    [J]. ANALYTICA CHIMICA ACTA, 2003, 499 (1-2) : 157 - 165
  • [9] Jang BB, 1999, J POLYM SCI POL CHEM, V37, P3169, DOI 10.1002/(SICI)1099-0518(19990815)37:16<3169::AID-POLA14>3.3.CO
  • [10] 2-C