Flow-induced vibration in two-phase flow with wire coil inserts

被引:14
作者
Kim, Dae Hun [1 ]
Chang, Soon Heung [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, Taejon 305701, South Korea
关键词
flow-induced vibration; two-phase flow; wire coil;
D O I
10.1016/j.ijmultiphaseflow.2007.08.009
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Information of flow-induced vibration (FIV) in two-phase flow with wire coil inserts at atmospheric pressure, is presented in this study. FIV was measured in an upward vertical tube for four different wire coil inserts using an air-water mixture as process fluid. Vibration increased along with mass flux and quality. The narrower wire coils produced more vibration. The FIV prediction correlation for two-phase flow with wire coil inserts was experimentally developed with coefficient correlation value of 0.956. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:325 / 332
页数:8
相关论文
共 12 条
[1]   RESPONSE OF REACTOR INTERNALS TO FLUCTUATING PRESSURE FORCES [J].
AUYANG, MK .
NUCLEAR ENGINEERING AND DESIGN, 1975, 35 (03) :361-375
[2]   ENHANCEMENT OF CHF WATER SUBCOOLED FLOW BOILING IN TUBES USING HELICALLY COILED WIRES [J].
CELATA, GP ;
CUMO, M ;
MARIANI, A .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1994, 37 (01) :53-67
[3]  
Inaba H, 1994, JSME B, V60, P240
[4]  
INABA H, 1994, T JPN SOC MECH ENG, V60, P240
[5]   Two phase flow patterns and boiling heat transfer in tubes containing helical wire inserts .1. Flow patterns and boiling heat transfer coefficients [J].
Lan, J ;
Disimile, PJ ;
Weisman, J .
JOURNAL OF ENHANCED HEAT TRANSFER, 1997, 4 (04) :269-281
[6]  
LEE S, 1996, T JAPAN SOC MECH E B, V62, P712
[7]  
LEE S, 1998, T JPN SOC MECH ENG-B, V64, P2615
[8]  
MISHIMA K, 1982, 7TH INT HEAT TRANSF, V4, P309
[9]  
NAMIE S, 1990, T JPN SOC MECH ENG-B, V56, P1113
[10]  
NISHIKAWA K, 1973, T JPN SOC MECH ENG, V39, P1268