Attenuation Correction Methods Suitable for Brain Imaging with a PET/MRI Scanner: A Comparison of Tissue Atlas and Template Attenuation Map Approaches

被引:70
作者
Malone, Ian B. [1 ]
Ansorge, Richard E. [1 ]
Williams, Guy B. [2 ]
Nestor, Peter J. [3 ]
Carpenter, T. Adrian [2 ]
Fryer, Tim D. [2 ]
机构
[1] Univ Cambridge, Cavendish Lab, Cambridge CB3 0HE, England
[2] Univ Cambridge, Addenbrookes Hosp, Dept Clin Neurosci, Wolfson Brain Imaging Ctr, Cambridge CB3 0HE, England
[3] Univ Cambridge, Addenbrookes Hosp, Dept Clin Neurosci, Neurol Unit, Cambridge CB3 0HE, England
基金
英国工程与自然科学研究理事会; 英国医学研究理事会;
关键词
attenuation correction; brain; nonrigid registration; PET/MRI scanner; CEREBRAL 3D PET; IMAGES;
D O I
10.2967/jnumed.110.085076
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Modeled attenuation correction (AC) will be necessary for combined PET/MRI scanners not equipped with transmission scanning hardware. We compared 2 modeled AC approaches that use nonrigid registration with rotating Ge-68 rod-based measured AC for 10 subjects scanned with F-18-FDG. Methods: Two MRI and attenuation map pairs were evaluated: tissue atlas-based and measured templates. The tissue atlas approach used a composite of the BrainWeb and Zubal digital phantoms, whereas the measured templates were produced by averaging spatially normalized measured MR image and coregistered attenuation maps. The composite digital phantom was manually edited to include 2 additional tissue classes (paranasal sinuses, and ethmoidal air cells or nasal cavity). In addition, 3 attenuation values for bone were compared. The MRI and attenuation map pairs were used to generate subject-specific attenuation maps via nonrigid registration of the MRI to the MR image of the subject. SPM2 and a B-spline free-form deformation algorithm were used for the nonrigid registration. To determine the accuracy of the modeled AC approaches, radioactivity concentration was assessed on a voxelwise and regional basis. Results: The template approach produced better spatial consistency than the phantom-based atlas, with an average percentage error in radioactivity concentration across the regions, compared with measured AC, of -1.2% +/- 1.2% and 1.5% +/- 1.9% for B-spline and SPM2 registration, respectively. In comparison, the tissue atlas method with B-spline registration produced average percentage errors of 0.0% +/- 3.0%, 0.9% +/- 2.9%, and 2.9% +/- 2.8% for bone attenuation values of 0.143 cm(-1), 0.152 cm(-1), and 0.172 cm(-1), respectively. The largest errors for the template AC method were found in parts of the frontal cortex (-3%) and the cerebellar vermis (-5%). Intersubject variability was higher with SPM2 than with B-spline. Compared with measured AC, template AC with B-spline and SPM2 achieved a correlation coefficient (R-2) of 0.99 and 0.98, respectively, for regional radioactivity concentration. The corresponding R-2 for the tissue atlas approach with B-spline registration was 0.98, irrespective of the bone attenuation coefficient. Conclusion: Nonrigid registration of joint MRI and attenuation map templates can produce accurate AC for brain PET scans, particularly with measured templates and B-spline registration. Consequently, these methods are suitable for AC of brain scans acquired on combined PET/MRI systems.
引用
收藏
页码:1142 / 1149
页数:8
相关论文
共 50 条
  • [31] Practical issues and limitations of brain attenuation correction on a simultaneous PET-MR scanner
    J. E. Mackewn
    J. Stirling
    S. Jeljeli
    S-M. Gould
    R. I. Johnstone
    I. Merida
    L. C. Pike
    C. J. McGinnity
    K. Beck
    O. Howes
    A. Hammers
    P. K. Marsden
    EJNMMI Physics, 7
  • [32] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    Izquierdo-Garcia, David
    Sawiak, Stephen J.
    Knesaurek, Karin
    Narula, Jagat
    Fuster, Valentin
    Machac, Joseph
    Fayad, Zahi A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (08) : 1574 - 1584
  • [33] A hybrid method for generation of attenuation map for MR-based attenuation correction of PET data in prostate PET/MR imaging
    Mehdi Shirin Shandiz
    Mohammad Hadi Arabi
    Pardis Ghafarian
    Mehrdad Bakhshayesh Karam
    Hamidreza Saligheh Rad
    Mohammad Reza Ay
    EJNMMI Physics, 1 (Suppl 1)
  • [34] The usefulness of calculated attenuation correction in the evaluation of metallic artifacts on brain PET/CT Imaging
    Almodovar, Samuel
    White, Sharon L.
    Modarresifar, Homayoun
    Ojha, Buddhiwardhan C.
    CLINICAL NUCLEAR MEDICINE, 2006, 31 (09) : 554 - 555
  • [35] Comparison of Methods of Attenuation and Scatter Correction in Brain Perfusion SPECT
    Hayashi, Masuo
    Deguchi, Jun
    Utsunomiya, Keita
    Yamada, Makoto
    Komori, Tsuyoshi
    Takeuchi, Masayasu
    Kanna, Kensei
    Narabayashi, Isamu
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2005, 33 (04) : 224 - 229
  • [36] A Path to Qualification of PET/MRI Scanners for Multicenter Brain Imaging Studies: Evaluation of MRI-Based Attenuation Correction Methods Using a Patient Phantom
    Catana, Ciprian
    Laforest, Richard
    An, Hongyu
    Boada, Fernando
    Cao, Tuoyu
    Faul, David
    Jakoby, Bjoern
    Jansen, Floris P.
    Kemp, Bradley J.
    Kinahan, Paul E.
    Larson, Peder
    Levine, Michael A.
    Maniawski, Piotr
    Mawlawi, Osama
    McConathy, Jonathan E.
    McMillan, Alan B.
    Price, Julie C.
    Rajagopal, Abhejit
    Sunderland, John
    Veit-Haibach, Patrick
    Wangerin, Kristen A.
    Ying, Chunwei
    Hope, Thomas A.
    JOURNAL OF NUCLEAR MEDICINE, 2022, 63 (04) : 615 - 621
  • [37] Impact of Tissue Classification in MRI-Guided Attenuation Correction on Whole-Body Patlak PET/MRI
    Zhuang, Mingzan
    Karakatsanis, Nicolas A.
    Dierckx, Rudi A. J. O.
    Zaidi, Habib
    MOLECULAR IMAGING AND BIOLOGY, 2019, 21 (06) : 1147 - 1156
  • [38] One registration multi-atlas-based pseudo-CT generation for attenuation correction in PET/MRI
    Arabi, Hossein
    Zaidi, Habib
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (11) : 2021 - 2035
  • [39] Quantitative analysis of MRI-guided attenuation correction techniques in time-of-flight brain PET/MRI
    Mehranian, Abolfazl
    Arabi, Hossein
    Zaidi, Habib
    NEUROIMAGE, 2016, 130 : 123 - 133
  • [40] Evaluation of three methods for delineation and attenuation estimation of the sinus region in MR-based attenuation correction for brain PET-MR imaging
    Linden, Jani
    Teuho, Jarmo
    Teras, Mika
    Klen, Riku
    BMC MEDICAL IMAGING, 2022, 22 (01)