Comparing Surf Lifeguards and Nurse Anesthetists' Use of the i-gel Supraglottic Airway Device - An Observational Simulation Study

被引:0
作者
Norkjaer, Louise [1 ]
Staerk, Mathilde [1 ,2 ,3 ]
Lauridsen, Kasper G. [1 ,2 ,3 ]
Gallacher, Tabita K. [4 ]
Loyche, Jakob B. [5 ]
Krogh, Kristian [1 ,4 ]
Lofgren, Bo [1 ,3 ,6 ,7 ]
机构
[1] Aarhus Univ Hosp, Res Ctr Emergency Med, Aarhus, Denmark
[2] Randers Reg Hosp, Clin Res Unit, Randers, Denmark
[3] Randers Reg Hosp, Dept Internal Med, Skovlyvej 15, DK-8930 Randers, NE, Denmark
[4] Aarhus Univ Hosp, Dept Anesthesiol & Intens Care, Aarhus, Denmark
[5] Randers Reg Hosp, Dept Surg & Intens Care, Randers, Denmark
[6] Aarhus Univ Hosp, Dept Cardiol, Aarhus, Denmark
[7] Aarhus Univ, Inst Clin Med, Aarhus, Denmark
来源
OPEN ACCESS EMERGENCY MEDICINE | 2020年 / 12卷
关键词
cardiopulmonary resuscitation; drowning; ventilation; supraglottic airway; surf lifeguards; nurse anesthetists; RESUSCITATION COUNCIL GUIDELINES; BASIC LIFE-SUPPORT; BAG-VALVE-MASK; CARDIOPULMONARY-RESUSCITATION; CARDIAC-ARREST; VENTILATION; MANNEQUINS; INSERTION;
D O I
10.2147/OAEM.S239040
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: Using a supraglottic airway (SGA) may provide more effective ventilations compared with a mouth-to-pocket-mask for drowning victims. SGAs are widely used by nurse anesthetists but it is unknown whether surf lifeguards can use SGAs effectively. We aimed to compare the use of SGA by surf lifeguards and experienced nurse anesthetists. Materials and Methods: Surf lifeguards inserted a SGA (i-gel O-2, size 4) in a resuscitation manikin during cardiopulmonary resuscitation (CPR) and nurse anesthetists inserted a SGA in a resuscitation manikin placed on a bed, and performed ventilations. Outcome measures: time to first ventilation, tidal volume, proportion of ventilations with visible manikin chest rise, and ventilations within the recommended tidal volume (0.5-0.6 L). Results: Overall, 30 surf lifeguards and 30 nurse anesthetists participated. Median (Q1-Q3) time to first ventilation was 20 s (15-22) for surf lifeguards and 17 s (15-21) for nurse anesthetists (p=0.31). Mean (SD) tidal volume was 0.55 L (0.21) for surf lifeguards and 0.31 L (0.10) for nurse anesthetists (p<0.0001). Surf lifeguards and nurse anesthetists delivered 100% and 95% ventilations with visible manikin chest rise (p=0.004) and 19% and 5% ventilations within the recommended tidal volume, respectively (p<0.0001). Conclusion: In a simulated setting, there was no significant difference between surf lifeguards and experienced nurse anesthetists in time to first ventilation when using a SGA. Surf lifeguards delivered a higher tidal volume, and a higher proportion of ventilations within guideline recommendations, but generally ventilations caused visible manikin chest rise for both groups.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 23 条
  • [1] Comparison between the LMA Classic™ and new I-gel™ supraglottic airway device: a manikin study
    Kwak, D. I.
    Yoo, J. H.
    No, H. W.
    Sohn, J. D.
    Kim, Y. J.
    Nah, J. H.
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2013, 20 (01) : 25 - 33
  • [2] i-gel supraglottic airway in clinical practice: a prospective observational multicentre study
    Theiler, L.
    Gutzmann, M.
    Kleine-Brueggeney, M.
    Urwyler, N.
    Kaempfen, B.
    Greif, R.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (06) : 990 - 995
  • [3] The I-gel®, a single-use supraglottic airway device with a non-inflatable cuff and an esophageal vent: an observational study in children
    Beylacq, L.
    Bordes, M.
    Semjen, F.
    Cros, A. -M.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2009, 53 (03) : 376 - 379
  • [4] A randomised crossover trial comparing the i-gel supraglottic airway and classic laryngeal mask airway
    Janakiraman, C.
    Chethan, D. B.
    Wilkes, A. R.
    Stacey, M. R.
    Goodwin, N.
    ANAESTHESIA, 2009, 64 (06) : 674 - 678
  • [5] The use of an i-gel supraglottic airway for the airway management of a patient with subglottic stenosis: a case report
    Donaldson, W.
    Michalek, P.
    MINERVA ANESTESIOLOGICA, 2010, 76 (05) : 369 - 372
  • [6] Introduction of the i-gel supraglottic airway device for prehospital airway management in a UK ambulance service
    Duckett, Jay
    Fell, P.
    Han, K.
    Kimber, C.
    Taylor, C.
    EMERGENCY MEDICINE JOURNAL, 2014, 31 (06) : 505 - 507
  • [7] A prospective single-center observational study to assess the efficacy of the second-generation supraglottic airway device I-gel in laparoscopic surgeries in children
    Goyal, Rakhee
    Chauhan, Rajat
    Anand, Rajan
    Goyal, Manoj
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2020, 36 (01) : 20 - 24
  • [8] Risk factors for postoperative sore throat associated with i-gel™, a supraglottic airway device
    Taniguchi, Tomoya
    Fujii, Tasuku
    Taniguchi, Nanako
    Nishiwaki, Kimitoshi
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2022, 84 (02): : 319 - 326
  • [9] Analysing the efficacy of the I-gel supraglottic airway device in the supine and lateral decubitus positions
    Saracoglu, Kemal Tolga
    Demir, Ali
    Pehlivan, Gokhan
    Saracoglu, Ayten
    Eti, Zeynep
    ANAESTHESIOLOGY INTENSIVE THERAPY, 2018, 50 (04) : 259 - 262
  • [10] Efficiency of I-gel supraglottic airway device during mechanical ventilation in supin and lateral decubitus position in obese patient; prospective observational study
    Farouk, Inas
    Abdelhamid, Bassant Mohamed
    Wishahy, Mohamed Kadry
    Mohamed, Hassan
    Hassan, Mohamed Mahmoud
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2020, 36 (01): : 126 - 133